| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: AGE (I) Suryalanka Name of Work: REPAIR / REPLACEMENT OF SOLAR STREET LIGHT / WATER HEATERS WITH ALLIED ITEMS AT AF STN SURYALANKA Contract No: AGE (I) / SL / OF 2026 - 27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Works Item Code / Make Approximate No. of Units Required UNIT Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | S&F in replacement complete power circuit board for charge control current rating of 5/6 Amps for dusk dawn operation including fixing on existing solar street light by removing unsv existing circuit all as specified and as directed. |
| 3 | S&F in replacement of 12 W LED solar light fitting conforming to IP-65/66 with provision of batter low indication, in place of existing u/s LED/CFL fitting of wattage not more than 12 Watt of solar light including necessary arrangment for fixing of lights on existing solar pole like clamp, bracket, nuts & bolts etc all as specified and as directed. |
| 4 | S&F in replacement of 2 core 1.5 sqmm PVC Insulated and Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Cable for Voltage Grade 1100 Volts as per IS: 694:1990 complete including making necessary connection by using proper connecting spares and taking down old unsv cable all as specified and as directed. |
| 5 | S&F in replacement of smart intergrated all in one solar panel with street light of 24 Watt, 5700 K with High efficiency Mono crystalline solar PV Module, Lithium Ferro Phosphate battery with in build BMS technology, High Efficacy LED, MPPT solar charge controller and Aluminium Extruded body & is specially programmed to automatically contrtol the dimming and brightness of light, which increases the backup time including all necessary spares/connectors required for illumination of the solar light including necessary fixing arrangement for fixing on the existing pole (80mm) complete all as specified and as directed |
| 6 | S&F in replacement of plastic battery box of size not less than 0.45 x 0.20 x 0.27 mtr of thickness not less than 5 mm for housing the existing battery all as specified and as directed. |
| 7 | S&F in replacement Maintenance free battery of capacity of 12 volts 42 AH along with copper connectors complete all as specified and as directed. |
| 8 | S&F in replacement of UNSV solar tube collector of size 48 mm dia/150 mm length (suitable size for existing panel) and fixing arrangement to existing panel like screws, washers etc complete including taking down cracked / broken tubes and pieces from site complete all as specified and as directed. |
| 9 | M&L for cleaning of solar stainless tank of 100 ltrs capacity by opening drain plug, pipe line and reconnecting the same after cleaning, brazing of minor leakages of tank and testing by replacing silicon gas cuts and rubber gas cut as per site requirement complete all as specified and as directed. |
| 10 | S&F in Replacement of heating element with thermostat 2000 watt for 100 ltr solar heater as per the requirement of existing heater. |
| 11 | M&L for Removing the existing paint / rust from the steel surface and Painting of existing solar panel frame and stand of 100 ltr solar water heater with two coat of synthetic enamel paint complete all as specified and as directed. |
| 12 | S&F in repairs CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings of outer dia 25 mm for HOT water pipes suitable upto 82 Degree, pressure not less than 7.0 kg/sqcm along with fittings fixed on walls/ceiling or laying in floors complete all as specified and as directed. |
| 13 | M&L for Cutting existing steel tubing of bore upto 25 mm dia for insertion of new nipple/ pipe by removing rusted/ blocked portion, bends, tees, and other alterations including threading of both cutting edges/ inserting nipple and connecting complete all as specified and as directed. |
| 14 | S&F in repairs CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings of outer dia 32 mm for Cold water pipes suitable upto 23 Degree, pressure not less than 2.8 kg/sqcm along with fittings fixed on walls/ceiling or laying in floors complete all as specified and as directed. |
| 15 | M&L for Cleaning of solar cold water storage tank by disconnecting the inlet/out let pipe and removing all scale and dirt, etc from tanks and from mouth of circulating pipe not exc. 250 ltrs. Including replacement of leaked tank nipple, sokcet, union near tank pipe of size upto 25 mm GI Complete all as specified and as directed. |
| 16 | S&F in replacement of 25 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for pipe including taking down unsv gate valve and screwing of old pipe of any type GI/PP-R/CPVC both ends and fixed complete all as specified and as directed. |
| 17 | S&F in replacement of rotational moulded polyethylene water storage tanks (cylindrical vertical with threading type closed top) hoisted and fixed in position all as specified in SSR-Part-I of 250 ltrs capacity including giving neceesary connection for inlet pipe and out let pipe by using tank connecting nipple for the pipe size upto 25 mm GI and float valve copper, plastic globe and connecting rod complete all as specified and as directed. |
| 18 | S&F in replacement flat plate collector with working pressure 245 kpa, Absorber is made up of copper, confirming to IS 12933 or its latest alongwith flexible heat water tubes from collector to tank complete all as specified and as directed. |
| 19 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded of size 10 Sqmm including taking down old unsv service cable complete all as specified |
| 20 | M&L supports, clamps and back plates fabricated from structural steel sections on solar street light pole or on angle iron legs above ground level as required at site for placing of battery box including hinges, nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including for Dismantling of exisitng battery box/battery holder complete all as specified and as directed. |
| 21 | S&F in replacement of solar hot water tank stainless steel of capacity 100 Ltr suitable for existing solar hot water system and making necessary arrangement like cutting, welding stand, nuts and bolts for fixing the same at existing place including taking down old unsv tank complete all as specified and directed Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |