| Sl. No. | Item Description |
| 1 | Schedule 'A' Part-I (BUILDINGS AND STRUCTURES)This Schedule (contains under mentioned Sl item No. 1.01 & 1.02) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6. |
| 2 | Construction of RCC operator cum storage room alongwith attached toilet new STIR building including all fittings and fixtures complete all as specified and as shown on drawings. |
| 3 | Construction of RCC operator cum storage room alongwith attached toilet new Admin building including all fittings and fixtures complete all as specified and as shown on drawings. |
| 4 | Lump sum price worked out by the Contractor for “B/R WORK SERVICES FOR DATA CENTRE FACILITY\\" as listed in Schedule ‘A’ Part - II representing __________ % __________________ percent Above / Below the lump sum price of `16,19,282.95 inserted by the MES in Schedule ‘A’ Part - II |
| 5 | Lump sum price worked out by the Contractor for “B/R PORTION (02 Nos COVER SHEDS) SITE\\" as listed in Schedule ‘A’ Part - III representing __________ % __________________ percent Above / Below the lump sum price of `20,87,349.10 inserted by the MES in Schedule ‘A’ Part - III |
| 6 | Lump sum price worked out by the Contractor for “EXCAVATION AND EARTHWORK\\" as listed in Schedule ‘A’ Part - IV representing __________ % __________________ percent Above / Below the lump sum price of `42,173.13 inserted by the MES in Schedule ‘A’ Part - IV |
| 7 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - V representing __________ % ____________ percent Above / Below the lump sum price of `10,74,723.00 inserted by the MES in Schedule ‘A’ Part - V |
| 8 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VII representing __________ % ____________ percent Above / Below the lump sum price of ₹33,783.45 inserted by the MES in Schedule ‘A’ Part - VII |
| 9 | Lump sum price worked out by the Contractor for “ROAD / PATH / CULVERT / HARDSTANDING” as listed in Schedule ‘A’ Part - VII representing ________ % ____________ percent Above / Below the lump sum price of ₹5,00,073.51 inserted by the MES in Schedule ‘A’ Part - VII |
| 10 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - VIII representing _______ % _________________ percent Above / Below the lump sum price of `1,38,506.42 inserted by the MES in Schedule ‘A’ Part - VIII |
| 11 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IX representing __________ % _________________ percent Above / Below the lump sum price of ₹19,67,773.00 inserted by the MES in Schedule ‘A’ Part - IX |
| 12 | Lump sum price worked out by the Contractor for “REFRIGERATION AND AIR CONDITIONING” as listed in Schedule ‘A’ Part - X representing __________ % _________________ percent Above / Below the lump sum price of ₹7,22,387.00 inserted by the MES in Schedule ‘A’ Part - X |
| 13 | Lump sum price worked out by the Contractor for “UPS” as listed in Schedule ‘A’ Part - XI representing __________ % _________________ percent Above / Below the lump sum price of ₹1,53,436.00 inserted by the MES in Schedule ‘A’ Part - XI |
| 14 | Lump sum price worked out by the Contractor for “DG SET” as listed in Schedule ‘A’ Part - XII representing __________ % _________________ percent Above / Below the lump sum price of ₹24,74,478.00 inserted by the MES in Schedule ‘A’ Part - XII |
| 15 | Lump sum price worked out by the Contractor for “DG SET (SPECIAL ITEM)” as listed in Schedule ‘A’ Part - XIII representing __________ % _________________ percent Above / Below the lump sum price of ₹24,84,124.00 inserted by the MES in Schedule ‘A’ Part - XIII |
| 16 | Schedule 'A' Part - XIVThis Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 15 to 75.03 |
| 17 | B/R WORK SERVICES FOR DATE CENTRE FACILITY S&F 5.5 mm thick wave free toughened clear glass for fixing in uPVC window complete all as specified and directed. |
| 18 | Supply and fix in repairs venetian blinds vertical type 100 mm width with approved fabric and powder coated aluminium fittings such as top rails, metal weight nylon button loops etc to match with the top rail metal base complete all as specified and directed |
| 19 | M&L Surface preparation including putty application.Providing and applying two coats of Flame shield primer followed by two coats of flame shield finsh paint. Oil modified alkyd paint, smooth & glossy finishes, % volume 42.0+2.0, Theoretical VOC (gms/ltr) 440-500 (depending on shade), white and a wide range of tinable shades, smooth uniform, free following, and suitable for brushing (80-120 Sec at 30 degree C, Ford Cup B4), Berger G.P. Thinner (800), Brushing : 70-80 Sec, Spraying 45-50 Sec, Brush, roller or spray, Theoretical Spreading Capacity 10-12 Sqm/Ltr/Coat, Surface Dry : Less than 5hrs (at 16-22 m DFT) Hard Dry : Less than 18 hrs (at 16-22 m DFT), Over coating interval : 18-24 hrs (Depending on ambient temp), Primer : Flame Shield Primer (Preferably two coats with an interval of 16 to 18 hrs). Ensure that the surface is free from dust, dirt loose particle & moisture, remobe existing paint, one or two coat of primer. For best results, it is advisable to give 12-14 hrs drying time before application of subsequent coats. D not over thin. Stir well before use. Top coat combining the attributes of resistance against flame and moderate gloss. Including removing existing surface finishes.For PRIMER COAT : Oil modified alkyd paint, smooth glossy, Flame Shield Primer (Preferably two coats with an interval of 16 to 18 hrs) complete all as specified and directed |
| 20 | S & F 12mm thick wave free toughened clear glass door with stainless steel fitting,fish mouth channel in bottom and top as per design with and including provision of all other neccessary fixture and accesaries,complete all as specified and directed. |
| 21 | S & F in repair Aluminium (Extruded Section body) body door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width & of weight between 61 to 80kg fixed in repairs complete all as specified and directed |
| 22 | Providing and fixing Automatic sensor double door each leaf weight 100kg width of doors=700-1200mm opening speed 400mm/s closing speed 300mm/s Door Hold Time = 0.5 to 10 sec. Manual Thrust 45N Supply voltage =AX 220 V Track Dimensions : WXHXL = 130 mm x 62 mmx2200/2400mm complete wiring and switches with full accessories complete all as specified and directedMake : Droma/Ozone |
| 23 | B/R PORTION (2 Nos COVER SHEDS) S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping complete all as specified and directed. |
| 24 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 25 | INTERNAL ELECTRIFICATIONTaking down carefully U/S aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc , removing all material for reuse/ issued under sch of credit and making good the distrubed surface as the existing one, complete all as specified and directed |
| 26 | Taking down old sub main wiring of any type and size complete all as specified and directed. |
| 27 | M & L for PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, of size , 2 core X 10 sq. mm drawn through suitable PVC non matallic rigid conduit with accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including complete all as specified and directed. |
| 28 | M & L for PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, of size , 4 core X 35 sq. mm drawn through suitable PVC non matallic rigid conduit with accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including complete all as specified and directed. |
| 29 | M & L for PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, of size , 4 core X 50 sq. mm drawn through suitable PVC non matallic rigid conduit with accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including complete all as specified and directed. |
| 30 | M & L for maintenance free chemical earthing complete with copper earth plate 90cm x 60cm x 5 mm thick buried directly in ground with copper bonded electrode of dia 17.2 mm rod(earth pit not less than 3 mtr deep below ground level) with top edge of the plate not less than 2.10 mtr below normal ground level, connected to and including copper earth strip of 32 x 6 mm by means of rivetting and brazing and protected by GI pipe light grade of suitable size up to the test point i.e. up to 7.5 mtr, including providing alternate layers up to full volume of pit by low resistivity earth enhancement graphite and VNT GC compound & earthing backfill compound including electra pill carbon & betonies based compound with charcoal dust and common salt, magnesium sulphate & vegetable soil all around the plate 15 cm depth and width for getting the earth resistance and NE values less than 1 Ohm and RCC cover, connecting to the test point and testing on ground complete and including excavation and earth work in any type of strata and cleaning of site all as specified in MES SSR Part-I and directed by Engineer-in-charge. |
| 31 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light 10 watts of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirement withDriver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. |
| 32 | complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 33 | Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver including making of suitable hole in the wall complete all as specified and directed. |
| 34 | M & L for PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, of size , 2 X 10 sq. mm drawn through suitable PVC non matallic rigid conduit with accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including complete all as specified and directed. |
| 35 | M & L for PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, of size , 4 X 35 sq. mm drawn through suitable PVC non matallic rigid conduit with accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including complete all as specified and directed. |
| 36 | M & L for PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, of size , 4 X 50 sq. mm drawn through suitable PVC non matallic rigid conduit with accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including complete all as specified and directed. |
| 37 | ROAD / PATH / CULVERT / HARDSTANDINGProviding and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 38 | Preparation of new concrete surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 39 | M&L Rendering 15 mm thick stone masonry wall surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 40 | S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 41 | Material and labour for sand filling under floor including watering, consolidation and well ramming complete all as specified and directed |
| 42 | SEWAGE DISPOSALS&F 160mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 43 | EXTERNAL ELECTRIFICATIONDesign, Supply and fixing of 11KV 3 way Ring Main Unit (RMU) 630Amps, 21KA/3 Sec Motorised outdoor type both side extensible type comprising of 03 outgoings fixed type SF6 insulated VCB. All light parts Bus Bars VCB connection of RMU max two modules shall be enclosed in single tank duly welded stainless steel tank of 2 mm thickness having IP 67 degree of protection filled with gas as insulation with leakage rate less than 0.1 % per year tested as per IEC 62271 - 200. RMU shall be complete with all accessories such as ring core CTs self powered micro process based numerical protection relay for O/C, S/C, E/F, cable support, all front cable terminations, mechanical indication for breaker ON / OFF / Trip / Spring charged, Mono meter as per IEC Standards 62271-200 including any civil works as required complete all as specified and as directed by Engr-in-charge.. The each VCB module should consist of following accessories: - |
| 44 | 3 NO'S OUTONGING SF6 VCB'S(a) 630 A, 350 MVA VCB module for making and breaking fault current along with OFF load isolator in series for isolation purpose and integral series earth switch of full making capacity.(b) Short time current - 21 KA/3 Sec.(c) Making capacity - 52.5 kA.(d) Auxiliary Contacts - 1 NO + 01 NC.(e) Impulse voltage withstand voltage - 75 KV.(f) Nominal operating gas pressure - 1.3-ABS.(g) Front cover Mechanism - IP 2X.(h) Cable cover - 4X.(i) Degree of protection - IP 54.(j) Internal arc type tested 21KA/1s.(k) 24 volts DC motorized spring charging mechanism for breaker operation.(l) Push button for breaker ON/OFF.(m) Cable box for front termination of the cable suitable for up to 1 run of 3core 95 or 120Sqmm, 11 KV XLPE Cable.(n) Push ON type right angle Boots.(o) Current Transformer (50/1, 2.5 VA, 5P10) for protection, Current Transformer (50/1, 2.5 VA, 0.5) for metering and 1 No Coupling Kit |
| 45 | (p) Self powered micro processor based relay 3 O/C 01 E/F with low and high set for over current and earth fault. Relay should have facility to display the maximum loaded current also. Relay should be flush mounted for incoming and outgoing VCB to trip the breaker from remote commands without shunt trip coil along. (q) Panel mounted 11 KV ring core CTs 50-100/1A, Class: 5P10, 2.5VA for protection as per IEC 50185.(r) Capacitive voltage indication fixed type system as per IEC 61243(s) Mechanical indication for breaker ON, OFF, earth, Trip, spring charge-discharge.Note : The above RMU to be couple with existing RMU at site & details are below for reference. (i) Make: ABB (Safe Plus) Equivelent make Siemens/ Schneider ( Note : The contractor shall ensure compatibility of the new RMU with the existing RMU to enable proper integration and smooth functioning of the system) |
| 46 | Supply, laying & testing HT cable 11000 volts Earthed , of size 3 core 240 sq mm XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor complete all as specified and directed. |
| 47 | Supply and fix cable jointing kit for 11 KV (E) grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 240 to 300 Sqmm complete all as specified and directed. |
| 48 | Supply and fix cable jointing kit for 11 KV (E) grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 to 300 Sqmm complete all as specified and directed. |
| 49 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 Sq mm 3.5 core (For data centre) complete all as specified and directed. |
| 50 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 630 Sq mm 3.5 core (for Data recovery) complete all as specified and directed. |
| 51 | Excavation in trenches n. exc. 1.5m wide and n exc. 1.5m in depth for taking out/laying cables in soft / loose soil complete all as specified and directed. |
| 52 | M&L for sand filling (pulverized stone dust) for cable cushioning inducing spreading and levelling complete all as specified and directed. Note - punned thickness only will be measured and paid |
| 53 | Supplying and laying un-reinforced precast concrete cable cover class HVP type I with peak of size 300 x 180 x 40mm complete all as specified and directed. |
| 54 | Supplying and laying un-reinforced precast concrete cable cover class LV, type I flat of size 300 x 180 x 40mm complete all as specified and directed. |
| 55 | Returning filling in, including, spreading, leveling, watering and well ramming in layers n exc. 25 cm complete all as specified and directed. |
| 56 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed. |
| 57 | M&L for cutting of bituminous road/floor for laying of pipe/cables not exc 1.5 mtr wide and not exceeding 1.5 mtr deep including refilling/with material and watering well ramming/compacting and making good with PCC 1:3:6 complete all as specified and directed.Note : PCC will be measured and paid under relevant items. |
| 58 | M & L for PCC (1:3:6) type C1 using 20 mm graded aggregate for making good the disturbed portion of road/floor/platform/foundation of RMU unit etc including form work complete all as specified and directed. |
| 59 | Supply & laying of GI pipe galvanised medium grade of 100 mm dia for protection of cable across road including taking down of old unsv complete all as specified and directed. |
| 60 | Supply & laying of GI pipe galvanised medium grade of 150 mm dia for protection of cable across road including taking down of old unsv complete all as specified and directed. |
| 61 | Supply, installing, testing and commissioning, factory made and tested LT Panel board of minimum size 1500 x800x 1000 mm , outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 1000 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 56 class protection and made of 3.15 mm MS sheet and 50x50x6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type, with aprons for cable entry, and fixing 2 Nos.danger notice plate of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 4 Sqmm. The platform shall be such that it is asper site requirement. |
| 62 | complete all as specified and directed including connections of all out going/in coming cables crimping suitable size Aluminium lugs for terminal connections of cables, necessary PCC foundation/ brick with plastering to the cable duct / wall damaging area , All out going feeders various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint with control switches complete all as specified and as directed Engr-in-Charge , The scope of work includes the following: Items (NOTE:-LT Panel board should be confirming to relevent IS/ICE 61439-part I&II Type Test certified. ) |
| 63 | (I) Incoming :- (i) Air circuit breaker 630 Amps, 4 Pole, (Fixed type) and microprocessor based, 415V,65kA, 50Hz, AC supply, microprocessor based release for Overload (L), Short-time (S), Instantaneous (I), and Ground fault (G), (IS-2516 marked, IS/IEC 60947-2.) complete .- 01 Nos.(ii) Ammeter Digital type, CT operated 0-630A range, - 01 Set (with selector switch and CT)(iii) Volt Meter Digital type 0-500 V range, - 01 Nos (With selector switch)(iv ) Indicating Lamp LED type 240 V 50 HZ AC supply) set of three colour (RYB)-01 set.(iv) Indication Lamp LED type 240 V 50 HZ AC supply, one set of two colour (Red and Green for ON/OFF indication of ACB -01 set.(v ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-01 set.(II) Outgoing :-(i) MCCB 4 Pole, Microprocessor Based 320A, Breaking capacity 36 KA, 415 V, 50 Hz with OC, SC, EF protection, -03Nos along with Spreader terminals (ii) MCB TPN 63 Amp C-Curve - 1 No (iii) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-03 set.( for each out going ) |
| 64 | Supply, installing, testing and commissioning, factory made and tested LT Panel board of minimum size 1700 x600x 1000 mm , indoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 52 class protection and made of 2 mm CRCA sheet and 50x50x6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type, with aprons for cable entry, and fixing 2 Nos.danger notice plate of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 4 Sqmm. The platform shall be such that it is asper site requirement. |
| 65 | complete all as specified and directed including connections of all out going/in coming cables crimping suitable size Aluminium lugs for terminal connections of cables, necessary PCC foundation/ brick with plastering to the cable duct / wall damaging area , All out going feeders various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint with control switches complete all as specified and directed. The scope of work includes the following: Items (NOTE:-LT Panel board should be confirming to relevent IS/ICE 61439-part I&II Type Test certified. ) |
| 66 | (A) EB Incoming:(i) MCCB 4 Pole, Microprocessor Based 320A, Breaking capacity 36 KA, 415 V, 50 Hz with OC, SC, EF protection, -01 Nos along with Spreader terminals (ii) Ammeter Digital type, CT operated 0-350A range, - 01 Set (with selector switch and CT)(iii) Volt Meter Digital type 0-500 V range, - 01 Nos (With selector switch)(iv ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set.(iv) Indication Lamp LED type 240 V 50 HZ AC supply, one set of two colour (Red and Green for ON/OFF indication of MCCB -01 set.(v ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-01 set.(B) DG Incoming:(i) MCCB 4 Pole, Microprocessor Based 250A, Breaking capacity 36 KA, 415 V, 50 Hz with OC, SC, EF protection, -01Nos along with Spreader terminals (ii) Ammeter Digital type, CT operated 0-350A range, - 01 Set (with selector switch and CT)(iii) Volt Meter Digital type 0-500 V range, - 01 Nos (With selector switch)(iv ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set.(v) Indication Lamp LED type 240 V 50 HZ AC supply, one set of two colour (Red and Green for ON/OFF indication of MCCB -01 set.(vi ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-01 set. |
| 67 | (B) Out going:(i) Automatic Transfer Switches (ATS) 320A, voltage 415V, 36kA and 3 phase 4 wire 4 pole automatic sensing of voltage/frequency deviations, mechanical interlocking for safety, transfer times <12 ms , and adjustable time delays to avoid nuisance switching complete, Sensing Logic: Microprocessor-based control to monitor under-voltage, over-voltage, frequency, and phase rotation, Protections: Input under/over-voltage, output overload, and short-circuit protection. Manual Operation: A handle must be included for manual operation during maintenance.Indicator Lights/Display: Visual monitoring of source availability, load position, and alarm status complete all as specified and directed complete Standards and Compliance UL 1008/cUL: IEC 60947-6-1: -01Nos(ii) Ammeter Digital type, CT operated 0-350A range, - 01 Set (with selector switch and CT)(iii) Volt Meter Digital type 0-500 V range, - 01 Nos (With selector switch)(iv) Indication Lamp LED type 240 V 50 HZ AC supply, one set of two colour (Red and Green for ON/OFF indication of MCCB -01 set.(v ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-01 set. |
| 68 | (c) Out going MCCBS(i) MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 25 KA, 415 V, 50 Hz with OC, SC, EF protection, -03 Nos along with Spreader terminals (ii) MCB TPN 63 Amp C-Curve - 1 No (iii) MCB SPN 20 Amp C-Curve - 1 No (iv) Ammeter Digital type, CT operated 0-350A range, - 03 Set (with selector switch and CT)(v) Volt Meter Digital type 0-500 V range, - 03 Nos (With selector switch)(vi) Indication Lamp LED type 240 V 50 HZ AC supply, one set of two colour (Red and Green for ON/OFF indication of MCCB -03 set.(vii ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-03 set. |
| 69 | Supply, installing, testing and commissioning, factory made and tested Automatic Transfer Switches (ATS) cum UPS LT Panel board , of minimum size 1700 x600x 1000 mm , indoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 55 class protection and made of 2 mm CRCA sheet and 50x50x6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type, with aprons for cable entry, and fixing 2 Nos.danger notice plate of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 4 Sqmm. The platform shall be such that it is asper site requirement. |
| 70 | complete all as specified and directed including connections of all out going/in coming cables crimping suitable size Aluminium lugs for terminal connections of cables, necessary PCC foundation/ brick with plastering to the cable duct / wall damaging area , All out going feeders various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint with control switches complete all as specified and as directed Engr-in-Charge , The scope of work includes the following: Items (NOTE:-LT Panel board should be confirming to relevent IS/ICE 61439-part I&II Type Test certified. ) |
| 71 | (A) EB Incoming:(i) MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 36 KA, 415 V, 50 Hz with OC, SC, EF protection, -01 Nos along with Spreader terminals (ii) Ammeter Digital type, CT operated 0-350A range, - 01 Set (with selector switch and CT)(iii) Volt Meter Digital type 0-500 V range, - 01 Nos (With selector switch)(iv ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set.(iv) Indication Lamp LED type 240 V 50 HZ AC supply, one set of two colour (Red and Green for ON/OFF indication of MCCB -01 set.(v ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-01 set. |
| 72 | (B) Incoming From ATS Panel 2(i) MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 25 KA, 415 V, 50 Hz with OC, SC, EF protection, -01Nos along with Spreader terminals (ii) Ammeter Digital type, CT operated 0-160A range, - 01 Set (with selector switch and CT)(iii) Volt Meter Digital type 0-500 V range, - 01 Nos (With selector switch)(iv ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set.(iv) Indication Lamp LED type 240 V 50 HZ AC supply, one set of two colour (Red and Green for ON/OFF indication of MCCB -01 set.(v ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-01 set. |
| 73 | (B) Out going:(i) Automatic Transfer Switches (ATS) 160A, voltage 415V, 36kA and 3 phase 4 wire 4 pole automatic sensing of voltage/frequency deviations, mechanical interlocking for safety, transfer times <12 ms , and adjustable time delays to avoid nuisance switching complete, Sensing Logic: Microprocessor-based control to monitor under-voltage, over-voltage, frequency, and phase rotation, Protections: Input under/over-voltage, output overload, and short-circuit protection. Manual Operation: A handle must be included for manual operation during maintenance. Indicator Lights/Display: Visual monitoring of source availability, load position, and alarm status complete all as specified and directed complete Standards and Compliance UL 1008/cUL: IEC 60947-6-1: -01Nos(ii) Ammeter Digital type, CT operated 0-350A range, - 01 Set (with selector switch and CT)(iii) Volt Meter Digital type 0-500 V range, - 01 Nos (With selector switch)(iv) Indication Lamp LED type 240 V 50 HZ AC supply, one set of two colour (Red and Green for ON/OFF indication of MCCB -01 set.(v ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-01 set. |
| 74 | (B) Out going MCCBS(i) MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 25 KA, 415 V, 50 Hz with OC, SC, EF protection, -03 Nos along with Spreader terminals (ii) MCCB 4 Pole, Microprocessor Based 63A, Breaking capacity 25 KA, 415 V, 50 Hz with OC, SC, EF protection, -03 Nos along with Spreader terminals (iii) MCB TPN 63 Amp C-Curve - 1 No (iv) Ammeter Digital type, CT operated 0-160A range, - 06Set (with selector switch and CT)(v) Volt Meter Digital type 0-500 V range, - 06 Nos (With selector switch)(vi) Indication Lamp LED type 240 V 50 HZ AC supply, one set of two colour (Red and Green for ON/OFF indication of MCCB -06 set.(vii ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-06 set. |
| 75 | M & L for chemical earthing complete with copper earth plate electrode 90cm x 60cm x 5 mm thick buried directly in ground (earth pit not less than 3 mtr deep below ground level) with top edge of the plate not less than 2.10 mtr below normal ground level, connected to and including copper earth strip of 32 x 6 mm by means of rivetting and brazing and protected by GI pipe light grade of suitable size up to the test point i.e. up to 7.5 mtr, including providing alternate layers up to full volume of pit by charcoal dust and common salt, magnesium sulphate & vegetable soil all around the plate 15 cm depth and width minimum including PCC pit chamber, watering pipe of 50mm dia medium grade GI pipe up to the top of the plate having funnel complete and RCC cover, connecting to the test point and testing on ground complete and including excavation and earth work in any type of strata and cleaning of site all as specified in MES SSR Part-I complete all as specified and directed. |
| 76 | M&L for taking out of old UNSV RCC two pole structure and dismantling of all clamps and other accessories including all T&P and crane work for safety purpose of other equipments in the sub station required for dismantling with transportation and deposited to E/M store for further deposition as per policy in vogue complete all as specified and directed. |
| 77 | EXTERNAL WATER SUPPLY Mateial and labour for laying of GI tubing medium grade of size 40 mm dia laid in trenches in any length with screwed and socket joints together with all galvanised steel fitting such as sockets, bends, elbows, tees, reducers, union etc, including drilling tapping jointing and testing complete all as specified and directed. |
| 78 | Excavation of trenches in any type of soft / loose soil n.exc 1.5 M wide and n.exc 1.5 M in depth for taking out / laying of pipe lines and getting out forming bottom surfaces to required gradients complete all as specified and directed. |
| 79 | Returning, filling in and including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. |
| 80 | Removing excavated surplus materials to a distance not exceeding 50 Mtrs and deposited where directed at a level not exceeding 1.5 Mtr .Above starting point complete all as specified and directed. |
| 81 | M & L for cutting the existing bituminous Road/PCC hard standing and getting out excavated material and making good the damage portion after laying of pipe by returning, filling including spreading , levelling, watering and wall ramming in layers not exceeding 25cm thick and PCC 1:2:4 type B1 using 20mm graded stone aggregate upto 30cm depth from top of the road complete all as specified and directed. |
| 82 | Material and labour for gun metal valves with iron wheel head screwed both ends suitable for GI tubing of 40 mm dia complete all as specified and as directed |
| 83 | M&L in repairs rotational moulded polythene water storage tank (Cylindrical vertical of capacity 1000 ltrs with closed top) hoisted and fixed in position complete all as specified and directed. |
| 84 | M&L for tapping with existing GI pipe of size 50 mm dia complete with all fittings required including earth work complete all as specified and directed. |
| 85 | Supply and fixing of ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe an of 40 mm dia fixed for the following sizes including taking out existing unserviceable complete all as specified and directed. (Minimum weight 15 mm -142 gms/20 mm - 20 gms/25 mm - 455 gms/40 mm - 690 gms). Make : Prayag or equivalent |
| 86 | REFRIGERATION AND AIR CONDITIONINGSupply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified and directed. |
| 87 | M&L for MS stand duly painted suitable for fixing 3/2 TR AC outdoor unit including nuts and bolts fixing complete all as specified and directed. |
| 88 | Supply and fixing in replacement chlorinated polyvinyal chloride (CPVC) pipes of 20 mm dia,having thermal stability for hot & cold water supply,including all CPVC plain and brass threaded fittings, This includes joint of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed. |
| 89 | Supply and fixing in replacement chlorinated polyvinyal chloride (CPVC) pipes of 25 mm dia,having thermal stability for hot & cold water supply,including all CPVC plain and brass threaded fittings, This includes joint of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed. |
| 90 | M&L for making opening/drilling of size 65 mm dia, using heavy duty stone driller/cutter machine in the stone masonary wall for installing spilit type air conditioners and for passing suction and discharge refrigerant pipe lines, drain pipe, cable etc and making good the disturbed surface complete all as specified and directed. |
| 91 | UPSSupply and fixing of on-line UPS three phase 4 wire , 50Hz IGBT technology smart touch panel LCD display, active power factor correction and other factors as per latest technology of capacity 80 KVA integration isolation transformer 3 phase 80 KVA 400 VAC, with communication port, including sealed maintenance free (SMF) battery with 30 minutes backup, pre fabricated open metal rack suitable for installation of batteries with communication ports suitable and batteries status etc. complete electric connection and testing complete all as specified and directed. |
| 92 | INPUTInput Voltage 415V AC +/- 10%, 3 phase, 4 Wire & groundInput frequency 50Hz +/-3 HzOUTPUTOutput Capacity 80KVA / 64KW_ 116A per phaseOutput Load PF 0.8 lag to unityOutput Voltage 400VAC ( Ph – Ph) , 4 wireOutput Frequency 50Hz + / - , 0.5% ( auto sensing)Voltage Regulation + /- 2%Output waveform Pure sine waveTotal Harmonics Distortion < 2% for liner Load & Non liner < 5%Inverter Technique IGBT Based high frequency PWM techniqueEfficiency ( Over all _ AC- AC) > 90%Crest factor 3:1 |
| 93 | Overload Capacity - 110% for 30 min, 150% for 10 sec and 200% for 10 cycleDC LinkDC Interlink Voltage 360V DCBattery Charging current 20A MaxBattery SMF 12V /200AH – 30 NosBackup Time 30 minutesGeneralSurge Protection Surge Protection @ Input sideSpecial Restart Feature- Auto RestartEthernet Connection LAN monitoring through EthernetOperating Temperature 0 to 50° CStorage temperature -25 ° C to 70 ° CMetering On LCD Display a) AC Input / Output voltage per phaseb) Loadc) DC voltage ( Battery voltage)d) Battery % ( battery status)e) Output Frequency |
| 94 | Indications LED/ LCDa) Mains ON / Line ON ( On Mimic)b) Inverter ON ( On Mimic)c) Battery ON charge (On LCD)d) Load ON inverter / output ( On Mimic)e) Load ON Bypass( On Mimic)f) Manual Bypass ON (On LCD)g) Mains abnormal (On LCD)h) Low Battery Imminent(On LCD)i) DC O/U Voltage(On LCD)j) INV O/U Voltage (On LCD)k) Inverter overload(On LCD)l) Overheat (On LCD)Connectors -Industrial grade connectors |
| 95 | DIMENSIONSMechanical Dimension ( Overall) as builtHeight : 1700mm (without shock mounts)Width : 670 mmDepth : 1150 mmIP Protection Class IP -51Colour 7807 Marpole black (STR)Note1 General safety requirements for UPS used in operator access areas IEC62040-1-1 Electromagnetic compatibility (EMC) requirements for UPS IEC62040-2,Method of specifying the performance and test requirements of UPS IEC62040-32 The above mentioned product standards incorporate relevant compliance clauses with generic IEC and EN standards for safety (IEC/EN/AS60950), electromagnetic emission and immunity (IEC/EN61000 series) and construction (IEC/EN60146 series and 60950). |
| 96 | Supply, installing, testing and commissioning, factory made and tested Automatic Transfer Switches (ATS) LT Panel board , indoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 55 class protection and made of 2 mm CRCA sheet and 50x50x6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type, with aprons for cable entry, and fixing 2 Nos.danger notice plate of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 4 Sqmm. The platform shall be such that it is asper site requirement. |
| 97 | complete all as specified and directed including connections of all out going/in coming cables crimping suitable size Aluminium lugs for terminal connections of cables, necessary PCC foundation/ brick with plastering to the cable duct / wall damaging area , All out going feeders various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint with control switches complete all as specified and as directed Engr-in-Charge , The scope of work includes the following: Items (NOTE:-LT Panel board should be confirming to relevent IS/ICE 61439-part I&II Type Test certified. ) |
| 98 | (A) Incoming From UPS supply 1& 2(i) MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 36 KA, 415 V, 50 Hz with OC, SC, EF protection, -02 Nos along with Spreader terminals (ii) Ammeter Digital type, CT operated 0-350A range, - 02 Set (with selector switch and CT)(iii) Volt Meter Digital type 0-500 V range, - 02 Nos (With selector switch)(iv ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-02 set.(iv) Indication Lamp LED type 240 V 50 HZ AC supply, one set of two colour (Red and Green for ON/OFF indication of MCCB -02 set.(v ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-02 set. |
| 99 | (B) Out going:(i) Automatic Transfer Switches (ATS) 160A, voltage 415V, 36kA and 3 phase 4 wire 4 pole automatic sensing of voltage/frequency deviations, mechanical interlocking for safety, transfer times <12 ms , and adjustable time delays to avoid nuisance switching complete, Sensing Logic: Microprocessor-based control to monitor under-voltage, over-voltage, frequency, and phase rotation, Protections: Input under/over-voltage, output overload, and short-circuit protection. Manual Operation: A handle must be included for manual operation during maintenance.Indicator Lights/Display: Visual monitoring of source availability, load position, and alarm status complete all as specified and directed complete Standards and Compliance UL 1008/cUL: IEC 60947-6-1: -01Nos(ii) Ammeter Digital type, CT operated 0-350A range, - 01 Set (with selector switch and CT)(iii) Volt Meter Digital type 0-500 V range, - 01 Nos (With selector switch)(iv) Indication Lamp LED type 240 V 50 HZ AC supply, one set of two colour (Red and Green for ON/OFF indication of MCCB -01 set.(v ) Indicating Lamp LED type 240 V 50 HZ AC supply one set of three colour (RYB)-01 set. |
| 100 | DG SET Supply and design of AMF cum auto synchronizing auto load sharing, auto load dependent start / stop panel suitable for 2 x 160 KVA DG Set complete with switchgears, MCCB 4 pole 36 KA of 250 Amps motorized operation as incoming of DG sets, common aluminum bus bar 500 Amps, indicating lamps, synchronizing automatic relay for synchronization, CTs of appropriate rating 10VA for each incoming of DG set, MCBs DP 6 Amps, neutral contactor 3 pole of appropriate rating, hooters for each DG set, selector switches for each incoming etc, all as required for automatic operation including control wiring of DG set complete all as specified and comprising of following accessories as directed :-(NOTE:-LT Panel board should be confirming to relevent IS/ICE 61439-part I&II Type Test certified. ) |
| 101 | Incoming from the DG set(a) MCCB 4 pole 250 Amps 36 KA, 415 volts microprocessor based self-powered protection unit with advance functions of logical selectivity, reverse power, current unbalance, over voltage and under voltage, under/over frequency - 2 No’s Each.(b) Digital multi-function meter with RS 485 port to measure A, V, KW, PF, CT operated, PM2230 - 2 No’s, (c) LED indicating lamp RYB-02 Sets.(d) Indicating lamp ON/OFF - 02 Sets.(e) Neutral contactor 3 pole of appropriate rating - 2 No’s(f) Control MCB SP C curve 6 Amps 10 KA- 16 Nos(g) DP MCB 6 Amps - 06 Nos.(h) SMPS and UPS as per manufacturer - 01 Set.(j) Battery charger with DC ammeter and voltmeter- 02 Set.(k) Glass relays with base as per manufacturer.(l) LT 3 phase 4 wire including CT's ratio 250/5 Amps 10VA - 02 Set.(m) Sync Controller : Woodward paralleling gen set- 02 No’s |
| 102 | (q) Panel builder should loop all Meters, Breakers of RS485 & terminate it at one point for making the Panel Smart & ready to communicate at single point through Ethernet Gateway PAS600/ Eqv & ethernet Switch inside Panel for Energy & Power Monitoring System software / BMS |
| 103 | Outgoing from the DG set(a) MCCB 4 pole 250 Amps 36 KA, 415 volts microprocessor based self-powered protection unit, LCD and multi-color display vertical orientation advance functions of over voltage and under voltage, under/over frequency each-01 No.(b) Digital multi-function meter with RS 485 port to measure A, V, KW, PF, CT operated, LT 3 phase 4 wire including CT's ratio 250/5 Amps, PM2230 - 01 Set.(c) LED indicating lamp RYB-01 Set.(d) Indicating lamp ON/OFF - 01 Set.(e) Neutral contactor 3 pole of appropriate rating-02 Nos.(f) Control MCB SP C curve 6 Amps 10 KA-As required 16 Nos.(g) DP MCB 6 Amps - 6 Nos.(h) LT 3 phase 4 wire including CT's ratio 250/5 Amps 10VA - 01 Set.(i) By pass Auto and Manual changeover switch type -1 No Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail