| 1 | Excavation in foundation in ordinary soil (Loam clay, or sand ) including lift upto 1.5 m & lift up to 30.0 Mtr & including all to proper completion of work as per D.S.R 2.8.1 |
| 2 | Concrete with 4 cm gauge brick ballast fine sand of 1.25 F.M and cement in proportion of 1:4:8 in foundation and under floor including supply of all materials labour T & P etc. required for proper completion of the work. S.I.No.275 |
| 3 | Brick work in 1:6 cement and coarse sand above 2.25 F.M. mortar in foundation and plinth including supply of all materials,labour and t&p etc required for proper completion of the work. as perD.S.R. 6.1.2 |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in 1:4 cement Coarse sand D.S.R 6.1.1 |
| 5 | Providing and laying R.C.C in 1:1.5:3 in cement coarse sand and grit all work upto plinth level excluding cost of centering, shuttering, and reinforcement as per D.S.R. 5.1.2 |
| 6 | Centering and shuttering including strutting, propping removal in foundation and footing of column DSR 5.9.1 |
| 7 | Providing and laying R.C.C in 1:1.5:3 in cement coarse sand and grit in wall columns, struts and posts above plinth level excluding cost of centering, shuttering, and reinforcement as per D.S.R. 5.2.2 |
| 8 | Centering and shuttering including removal in columns , pillars, posts abutment DSR 5.9.6 |
| 9 | Providing and laying R.C.C in 1:1.5:3 in cement coarse sand and grit in wall slabs, beams, chajja, shelves, lintel , sill bands above plinth level excluding cost of centering, shuttering, and reinforcement as per D.S.R. 5.3 |
| 10 | Centering and shuttering including removal in lintels, beams, plinth beams , girders cantilever DSR 5.9.5 |
| 11 | Centering and shuttering including strutting, propping removal in roofs, ssuspended floors, balconies DSR 5.9.3 |
| 12 | Brick work in 1:6 cement and coarse sand above 2.25 F.M. mortar in superstructure as perD.S.R. 6.4.2 |
| 13 | Brick work in Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level as per D.S.R6.13.2 |
| 14 | Mild steel work in R.C.C. including cutting and bebnding and all upto plinth level and above Plinth level as per D.S.R.5.22.1 |
| 15 | Structural steel work in built up section frames, trusses etc as per D.S.R 10.2 |
| 16 | Earth work in cutting /Filiing in ordinary Soil lead 30 m and lift 1.50 m including all as per S.I.253+231(A) |
| 17 | 12 mm thick plaster 1:6 cement fine sand as per D.S.R 13.1.2 |
| 18 | 12 mm thick plaster 1:6 cement fine sand as per D.S.R 13.1.2 |
| 19 | 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) D.S.R 13.7.1 |
| 20 | CC in 1:1.5:3 cement coarse sand and grit as per D.S.R 4.1.2. |
| 21 | Providing and laying ceramic glazed tiles flooring 30x30cm as per D.S.R 11.38 |
| 22 | Providing and fixing ceramic glazed wall tiles except burgundy, bottle green and black over 1:3 cement coarse sand mortar as per D.S.R. 8.31 |
| 23 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer as per D.S.R 13.5.1 |
| 24 | Finishing walls with Premium Acrylic Smooth exterior paint as per D.S.R 13.46.1 |
| 25 | Distempering with first quality acrylic distemper (ready mix ) over new work two or more coat as per D.S.R 13.41.1 |
| 26 | Painting over steel work with deluxe multi surface paint as per D.S.R.13.48.1 |
| 27 | Providing and applying white cement based putty of average thickness 1mm as per D.S. R no. 13.80 |
| 28 | Providing and filling brick bats in soak pit |
| 29 | Providing and Laying CPVC pipe32mm dia for external Work as per D.S.R,.18.9.4 |
| 30 | Providing and Laying CPVC pipe15 mm dia for external Work as per D.S.R,.17.7.2 |
| 31 | Providing and fixing wash basin 630x450mm with single 15mm pilaar tap as per D.S.R 17.7.2 |
| 32 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per D.S.R.18.48 |
| 33 | Providing and fixing water closet squatting pan (Indian Type W.C. pan ) incl all as per D.S.R 17.1.1 |
| 34 | Providing and fixing white vitreous china pedestal type water closet (European type W.C pan ) incl all as per D.S.R 17.2.1 |
| 35 | Providing and Fixing 110 mm P.V.C Rain water Pipe |
| 36 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore. D.S.R. 18.17.2 |
| 37 | Providing and Fixing PTMT bib cock 15mm nominal bore 90mm long as per D.S.R. 18.54.4 |
| 38 | Providing and fixing PTMT stop cock of approved quality and colour.15 mm nominal bore D.S.R 18.55.1 |
| 39 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15mm nominal bore D.S.R 18.74.2 |
| 40 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively D.S.R 17.23 |
| 41 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe D.S.R 17.24 |
| 42 | FOR INTERNAL ELECTRIFICATION-Wiring point for Light point, fan point,exhaust fan point, call bell point with 1.5 sqmm FRLS PVC insulated copper conductor in single core in surface /recessed medium class PVC conduit, with Modul;ar type switch including all as per DSR 1.10.1 Group A |
| 43 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in Recess,including providing and fixing 3 pin 15/16A modular socket and 15/16 A modular switch connections etc as required as per DSR 1.32 |
| 44 | Wiring for Circuit/Submain Wiring along with earth wire along with following size FRLS PVC insulated copper conductor in single core in surface /recessed medium class PVC conduit as required as per DSR 1.14.2 2x2.5sqmm +1x2.50sqmm earth wire) |
| 45 | Wiring for Circuit/Submain Wiring along with earth wire along with following size FRLS PVC insulated copper conductor in single core in surface /recessed medium class PVC conduit as required as per DSR 1.14. 3 2x4sqmm +1x4sqmm earth wire)No.1301(C). |
| 46 | Supply and fixing 5A to 32 A rating 240/415V , 10KA \\"C\\" curve MCB including all as per DSR 2.10.1 single Pole |
| 47 | Supply and fixing following rating double pole ,240V isolator in existing MCB Distribution Board including all as per DSR 2.12.1 40A |
| 48 | Supply and fixing Following way SPN sheet steel MCB distribution board ,240V , on surface /recess complete as per D.S.R. 2.3.1 6 Way Double door |
| 49 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. S.I.1413 CAT (AA) Please Enable Macros to View BoQ information |