| 1 | All in all General servicing and cleaning of various type airconditioners During Defect Laibility Period of Equipments including compressor, condensing/ cooling coil , refrigerant piping , fan motor , remote , charging of refrigerant when ever required as per OEM's recommendations to meet out the efficient performance of the equipment. |
| 2 | 3.0/4.0/5.0 Tr Ductable type Split type air conditioner |
| 3 | All in all comprehensive maintenance of various type air conditioners including repair / replacement of compressor, condensing/ cooling coil , refrigerant piping , fan motor , remote , charging of refrigerant whenever required and periodical servicing as per OEM's recommendations and standard terms & conditions of PWD to meet efficient performance of the equipment. |
| 4 | 1.5/1.8/2.0 Tr Split type air conditioner |
| 5 | All in all comprehensive maintenance of various type air conditioners including repair / replacement of compressor, condensing/ cooling coil , refrigerant piping , fan motor , remote , charging of refrigerant whenever required and periodical servicing as per OEM's recommendations and standard terms & conditions of PWD to meet efficient performance of the equipment. |
| 6 | 1.0/1.5/2.0 Tr window type air conditioner |
| 7 | 1.5/2.0/3.0/4.0 Tr Cassette type Split type air conditioner |
| 8 | 2.2/3.0/3.6/4.2 Tr Floor Standing Tower Type Split A.C. |
| 9 | All in all General servicing and cleaning of various type of Water cooler During Defect Laibility Period of Equipment including compressor, condensing/ cooling coil ,water tank with inner piping including charging of refrigerants when ever required , cleaning , servicing etc as per OEM's recommendations to meet out the efficient performance of the equipment. |
| 10 | Up to 60/120 Ltr capacity |
| 11 | All in all comprehensive maintenance of Water cooler including compressor, condensing/ cooling coil ,water tank with inner piping including repair / replacement of components like filters, membrane, charging of refrigerants whenever required , cleaning , servicing etc. as per OEM's recommendations and standard terms & conditions of PWD to meet efficient performance of the equipment. |
| 12 | Up to 60/120 Ltr capacity |
| 13 | 150/150 Ltr capacity |
| 14 | All in all comprehensive maintenance of Reverse Osmosis water purification system including repair / replacement of components ,consumables , cleaning , servicing etc as per OEM's Guide lines to meet out the TDS level of Water as per client requirement / standard norms to meet efficient performance of the equipment. |
| 15 | 12-15 Ltr/hr capacity |
| 16 | 25 Ltr/hr capacity |
| 17 | 50 Ltr/hr capacity |
| 18 | Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field ) |
| 19 | Technical Helper Having basic Knowledge of E&M Services |
| 20 | Technical Helper Having basic Knowledge of E&M Services |
| 21 | Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field ) |
| 22 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. |
| 23 | 25 mm |
| 24 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia |
| 25 | 50 mm dia per running inch length |
| 26 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. |
| 27 | Supply & fixing MS powder coated stand suitable for 2.5/3.0/4.0 Tr outdoor type of Split/Ductable/Tower AC. All as per pre approved by Engineer in charge. |
| 28 | SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves (size as per item no. 22.43),7 mil Glass Cloth with 3 coats of anti UV paint (on area which is exposed to weather) chase cutting, supports, making good the same with sand cement plaster etc. as required. |
| 29 | Dismentling of split air conditioner of any capacity/any type including existing indoor unit & outdoor unit , refrigerant piping , connecting cables , drain pipe etc. including shifting of dismentaled material to store complete as required |
| 30 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM must ensure that the cable is tested for complaince, either through their in house laboratory accrediated by NABL or by any Govt. laboratory accrediated by NABL and the laboratory's scope of accrediation should cover the requirements and testing procedure as per IS:10810. |
| 31 | Armoured |
| 32 | 4 core x 2.5 Sq.mm |
| 33 | GST@18% Please Enable Macros to View BoQ information |