| 1 | B-6/6.1.6 Random Rubble stone masonry with hard stone in Foundation and plinth in Cement Sand Mortar 1:6 (1 cement:6 sand) above 30 CM thick walls. |
| 2 | B-5/5.2.2 Brick work with F.P.S brick of class designation 75 in Super Structure above Plinth Level up to floor V level In all shapes and size in CM 1:6 ( 1 cement : 6 coarse sand) |
| 3 | B-5/5.3.1 Add extra for Square of rectangular pillars in superstructure brick work up to five story upto 45 cm length and all sides are free |
| 4 | B-4/4.1 Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 5 | B-4/4.2 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement, 3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and strut etc. M20 grade Nominal Mix / Design Mix |
| 6 | (B-3/3.2.2) Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 7 | B-4/4.9 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footings, strap beam, raft, bases of columns etc. |
| 8 | B-4/4.10.3 Centring & Shuttering with plywood or steel sheets including strutting propping bracing both ways with steel props and removal of formwork for up to floor five level for: Columns, pillars, posts and struts etc. |
| 9 | B-3/3.8 P&F precast CC coping 1:2:4 mix 50mm thick complete as per specification |
| 10 | B-9/9.1 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 11 | B-9/9.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work , including cutting, hoisting (height up to 10 m), fixing In position and applying a priming coat of approved steel primer all complete: |
| 12 | B-9/9.8+9.8.1 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 13 | B-9/9.33+9.35 P&F galvanized barbed wire. |
| 14 | B-12/12.3.2 Plaster on new surface on walls in Cement Sand Mortar 1:6 incl. Racking of joint etc. complete fine finished 20mm thick |
| 15 | B-12/12.3.3 Plaster on new surface on walls in Cement Sand Mortar 1:6 incl. Racking of joint etc. complete fine finished 12mm thick |
| 16 | B-12/12.35.1 Colour washing of all shades to give an even shade including all scaffolding New work (two or more coats) with a base coat of white washing with lime. |
| 17 | B-12/12.41.1 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 18 | S-3/3.16.3 P&F rigid PVC pipe (IS 4985 mark) class IInd /4 Kg P.SqCM ) approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant 110mm dia |
| 19 | B-12/12.46.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work |
| 20 | (B-4/4.13.2) Providing & fabricating reinforcement for RCC work incl. straightening,cutting,bending,placing in position and binding (Incl cost of binding wire)all complete floor V level:hot rolled deformed bars |
| 21 | E-18/18.10.1 Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LED Post top Luminarie made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminous efficacy ≥ 100 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current <750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Minimum lumen output 2500 lm Post top Luminarie |
| 22 | E-11/11.2.2.1 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 6.0 Sq. mm 2 core |
| 23 | E-06/6.10.1.1 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR:Metal door (single phase) IK-09 and IP-43 with Metal end box 4 Way (4+2) |
| 24 | E-06/6.1.1.2 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR:6A to 32A rating |
| 25 | E-06/6.2.2.3 Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR:Triple pole isolator 80 A/ 100 A rating |
| 26 | R-7/7.16.2.6 Providing and erecting direction and place identification retro reflectorised sign as per IRC:67 made of high intensity grade sheeting exclusive of lettering, border & signs fixed over aluminium sheeting, 2mm thick fixed on a mild steel angle iron frame 50mmX50mmX6mm supported on mild steel angle iron post 75X75X6mm upto the top of sign board, length of post from bottom of sign board is 2.85m upto foundation level post duly painted in black and white synthetic enamel alternate ship 30cm wide fixed to the ground by means properly designed foundation with M-15 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing & as per MORTH specifications clause 801 Double angle post 150cmX120cm |
| 27 | R-7/7.4.2 Providing & fixing letters/boarders from reflective tape of approved quality in standard width of MORTH specifications clause 800. providing and fixing letters (100mm wide) Please Enable Macros to View BoQ information |