| 1 | DSR item No.1.8Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | DSR Item No. 1.10Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | Group C |
| 5 | DSR Item No. 1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 6 | Group C |
| 7 | DSR Item No. 1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 8 | 3 x 1.5 sq. mm |
| 9 | 3 x 2.5 sq. mm |
| 10 | DSR Item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | DSR item No.1.23Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 12 | 3 Pin 5/6 A. socket outlet |
| 13 | 5/6 amps switch |
| 14 | DSR item No.1.24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 15 | 5/6 amps switch |
| 16 | Bell push |
| 17 | 3 Pin 5/6 A. socket outlet |
| 18 | 15/16 amps switch |
| 19 | 6 Pin 15/16 A. socket outlet |
| 20 | DSR item No.1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 21 | DSR item No.1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 22 | DSR item No.1.32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 23 | DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 24 | DSR item No.1.39 Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. |
| 25 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Single pole |
| 27 | Double pole |
| 28 | Triple pole and neutral |
| 29 | DSR ITEM NO. 8.5LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/ watt Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, (As per Complete Item No. 14 of the DNIT). |
| 30 | 12 -15 watt (Recess Type) |
| 31 | DSR Item No. 8.6.10LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, (As per Complete Item No. 15 of the DNIT).. |
| 32 | 36 Watt |
| 33 | DSR ITEM NO. LED 8.9.5Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,(As per Complete Item No. 16 of the DNIT). |
| 34 | 18-22 watt |
| 35 | DSR Item No. 8.16.3LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, (As per Complete Item No. 17 of the DNIT). |
| 36 | 100 Watt |
| 37 | 250 Watt |
| 38 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making good the damage, Carriage Charges, connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. |
| 39 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 300-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only. |
| 40 | DSR ITEM NO. 9.2Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, (As per Complete Item No. 19 of the DNIT). |
| 41 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 42 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 43 | Supply & Erection of 3 mm thick white glazed bakelite sheet on existing M.S. box. The job includes the cost of sheet and making holes & cutting and fixing with screws as required to complete the job. The make should be Super Hylam / Formica / GreenLam only. |
| 44 | Supply & erection of PVC Gang Box of anchor Panta make or its equivalent make Gold medal/ Havells only, including carriage, erection with suitable size of nuts/ bolts and other petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge |
| 45 | 1 Module |
| 46 | 3 Module |
| 47 | 4 Module |
| 48 | 6 Module |
| 49 | Supply and Erection of electronic step type socket type fan regulator in existing B.L. Sheet including making connection and petty material reqd. to complete the job. The fan regulator should be of Anchor Panta / Havells Reo/ Gold Medal Essenza make only |
| 50 | DSR Item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 51 | 100 A,30KA,FPMCCB |
| 52 | 125 A,36KA,FPMCCB |
| 53 | 200 A,36KA,FPMCCB |
| 54 | 400 A,50KA,FPMCCB |
| 55 | Supply, Erection, Testing and commissioning of the following accessories after dismantling the burnt out/ defective accessories with the help of ladder if required which shall be arranged by the firm at his own cost. The job includes cost of making connections with suitable rating copper wire and petty material required to complete the job to the entire satisfaction of Engineer-in-charge. |
| 56 | S/E of Electronic Driver suitable for existing 2’x2’ LED panel type fitting. The Driver should be of same make as that of existing fitting. |
| 57 | S/E of Electronic Driver suitable for existing 4’x1’ LED panel type fitting. The Driver should be of same make as that of existing fitting. |
| 58 | Supply, Erection, Testing and commissioning of the following items in existing LED fittings installed on pole upto 12 Mtr. Long / wall in place of burnt out / defective material with the help of hydraulic ladder / Crain with bucket which shall be arranged by the firm at his own cost. (As per Complete Item No. 25 of the DNIT). |
| 59 | S/E of Electronic Driver suitable for existing 100 Watt. LED fitting. The Driver should be same make of existing fitting. |
| 60 | S/E of Electronic Driver suitable for existing 150 Watt. LED fitting. The Driver should be same make of existing fitting. |
| 61 | Supply & erection of Cabin Fan 16” sweep oscillating type complete with blades & regulator. The fan should have 2 Nos. of pull cord switches, one for oscillation and one for speed regulation.(As per Complete Item No. 26 of the DNIT). |
| 62 | S/E of PVC Batton of following sizes. The Batton should be fixed on the wall with help of PVC rawl plug etc. to the entire satisfaction of EIC. |
| 63 | Size 1” |
| 64 | Size ¾” Please Enable Macros to View BoQ information |