| 1 | [13.32]Providing and fixing bolts including nuts and washers complete. |
| 2 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. |
| 3 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. |
| 4 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. |
| 5 | [24.4.3]STREET LIGHT 3. Supply and erection of 32mm dia metre 1.5 m long bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections. |
| 6 | NS Item -Supply and erection of 11kV Lightning Arrester as per approved makes and relevant specifications of UHBVN complete fixing with GI clamp, Nut and bolts up to entire satisfaction of Engineer-In-Charge (Excluding GST 18%). |
| 7 | NS Item -Supply and Erection of 11 kV G.O. Switch vertical mounted with heavy duty 9 Nos. post insulators suitable copper male and female contacts fixed on GI angle frame with G.I. Nut and Bolts including G.I. pipe and operating handle complete in all respect (Excluding GST 18%). |
| 8 | NS Item -Supply and Erection of 11 Mtr. Long PCC pole as per IS:1678-1960 specifications,11Mtr. Long 140mm x 200mm at top and 140mm × 400mm at bottom with working load of 400 Kg buried 2.20 M in ground as per UHBVNL specification.(Ex-GST 18%). |
| 9 | NS Item -Supply and Erection of ACSR conductor 50 mm2 conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments as per UHBVN specification including stringing and sagging as well as jointing and binding with insulators at supports complete in all respect upto the entire satisfaction of Engineer-in-Charge (Ex-GST 18%) |
| 10 | NS Item -Supply and Erection of Galvanized steel item (Flat, Angle, Channel) and Nut and Bolts etc. including cutting, bending to the required shape, drilling hole, carriage, loadingunloading complete in all respect up to the entire satisfaction of Engineer-in-charge.(Ex-GST 18%). |
| 11 | Supply and erection of 100 KVA Distribution transformer, outdoor type non sealed 3 phase 50 HZ 11/0.433/100 KVA Aluminum wound oil immersed naturally cooled, complete with fitting and accessories inclusive of Ist filling of oil and confirming to ISS 2026/1977 with latest amendments complete in all respect and similarity of transformer should have been got type tested including making of plate form and installation of transformer up to the entire satisfaction of Engineer-in-Charge. i. Voltage Rated Frequency permitted at 75 ‘ C ii. No Load losses (Max) = 220 watt iii. Free Load losses (Max) = 1760 watt The above losses are maximum allowable and these would not be any positive tolerance. (Ex-GST 18%). |
| 12 | Supply and Erection of 25 Watt pressure die cast aluminum housing LED street light fitting luminaire with multiple LED lenses and heat resistant polycarbonate. Cover glass IP65 of complete in all respect as per specifications having light efficiency of 120 lumens / watt up to the entire satisfaction of Engineer-in-charge of the work Make: Bajaj / Philips / LT/Panasonic/Wipro or equivalent make approved in HSVP (with 3 year free replacement warranty, mtc. including labour charges, free of cost). (Ex-GST 18%) |
| 13 | Supply and Erection of 9Mtr. Long PCC pole as per IS:1678-1960 specifications, 9Mtr. Long 105mm x 115mm at top and 105mm × 315mm at bottom with a working load of 200 Kg. buried 1.80 M in ground or as UHBVNL specification. |
| 14 | Supply and Erection of ACSR conductor 80 mm2 conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments as per UHBVN specification including stringing and sagging as well as jointing and binding with insulators at supports complete in all respect upto the entire satisfaction of Engineer-in-Charge (Ex-GST 18%) |
| 15 | Supply and Erection of HT Cradle Guard made of GI wire of SWG including fixing in 11kV line complete in all respect up to the entire satisfaction of the Engineer-In-Charge. (Ex-GST 18%). |
| 16 | Supply and Erection of LT Cradle Guard / Guard Reel made of GI wire of SWG including fixing in 11kV line complete in all respect up to the entire satisfaction of the Engineer-In-Charge. (Ex-GST 18%). |
| 17 | Supply and Erection of Stay set for HT line complete with GSS 7/8 SWG, Egg, insulator/ Disc Insulator, GI rod 20mm dia threaded up to 250mm length with Nut (wt.6.224kg), cross plate 460 mm of Channel 75×40×6mm (wt.5.330kg), Elbow (wt.2.240kg), clamp with Nut-Bolts etc. as per UHBVN specification complete in all respect up to the entire satisfaction of Engineer-in-charge. (Ex-GST 18%). |
| 18 | Supply and Erection of Stay set for LT line complete with GSS 7/8 SWG, Egg, insulator/ Disc Insulator, GI rod 20mm dia threaded up to 250mm length with Nut (wt.6.224kg), cross plate 460 mm of Channel 75×40×6mm (wt.5.330kg), Elbow (wt.2.240kg), clamp with Nut-Bolts etc. as per UHBVN specification complete in all respect up to the entire satisfaction of Engineer-in-charge. Please Enable Macros to View BoQ information |