| 1 | MCCB, MCB & DB'S |
| 2 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required. |
| 3 | Double pole |
| 4 | EARTHING |
| 5 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 6 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 7 | MV CABLE LAYING |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 9 | Upto 35 sq. mm |
| 10 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 11 | Supply and laying of following size Double walled Corrugated High Density Polyethylene pipe having corrugation on the outer wall and plain surface inner wall conforming to IS 14930 part- I and part -II complete with necessary HDPE fitting for protection and laying of 1.1 KV grade underground cable directly in ground at a depth 75cm including excavation and refilling the trench etc. as required. |
| 12 | Size : 40mm/32mm (OD / ID) |
| 13 | MV CABLE JOINTING & END TERMINATION |
| 14 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 15 | 4 X 16 sq. mm (28mm) |
| 16 | Fabrication, supply of out-door feeder pillar type made out of not less than 2.2 mm thick MS sheet and angle iron base frame with hinged door on both side and gowden locks welded on the door i/c painting connection inter-connection etc. as per CPWD specifications (Part IV & V) of following size and providing and fixing following switch gears with cable entry boxes for both incoming and outgoing cables termination, glands, interconnection, connections powder coated painting, earthings , including of all erection, Labelling of incoming and outgoing feeders & transport charges etc., as required. |
| 17 | Supply, Installation of outdoor type cubicle fabricated out of2.2 mm thick MS sheet free standing totally enclosed dust and vermin proof and locking arrangement of the board with size of 900mm x 700 mm x 250 mm deep (Nominal) double door type with 1)4P, 125A MCCB as incomer - 1No , 2) 4P 6-32A MCB - 4No 3)Timer and Contactor as a outgoing with necessary indication lamp and Hylam sheets for rail arrangements, connection and wirings including panel erections etc. as required. |
| 18 | Supplying of Cables. |
| 19 | Supply of aluminium Armoured XLPE UG CABLE 1.1KV as per ISI Specification IS:7098/(Part-I) 1988 with latest amendments. |
| 20 | 4x16 sq mm |
| 21 | Supplying and fixing of following size ISI marked PVC insulated and PVC unsheathed copper single core and multi-core shaethed bright annealed bare copper flexible cables for voltage grade 1.1 KV grade as required.(Make:Finolex,Gloster,Havells and Polycab) |
| 22 | 3x1.5 sqmm |
| 23 | Supply of Light Fixtures with Lamps |
| 24 | Supplying and fixing street light luminaire with die cast aluminum housing and toughened glass cover with min IP65 protection , with the LED Type fixtures of following Wattage complete with all accessories and drivers, LN6 heat sink minimum 5kVA surge protection low power LEDs with driving current less than 350mA etc. on existing brackets on street light poles including connection & loop earthing with 3 core 1.5 sqmm flexible PVC insulated PVC round sheathed copper conductor cable from street light box to fitting, testing and commissioning etc. as required. (with 5 years manufacturer's warranty) (Make: Havells,Bajaj,Crompton Greaves, & philips etc) |
| 25 | Supply and installation of Street light pole with a height of 3000 mm and 3 mm thick ,Top 70,Bottom-130mm, including base plate with the size of 200x200 mm and 12mm thick. 4 elongated hole (20x34) to suit for M16 bolt at CC of 140mm & cable entry hole 65mm and 4Nos of 16x450mm length “J” type bolt with 4 Nos of plain washer & 4Nos of M16x450LG Bolts each,1 no's of M10 Bolt for Earthing, 63 dia Pvc pipe for cable entry,Foundation RCC M50 Concrete(450x450x1100)mm and 36W,120 lm/W LED post top Street luminaries Epoxy powder coated pressure die-cast aluminium housing,Weatherproof gaskets provided for LEDs and control gear compartments and with size of dia 265mm x 185mm with IP66 protections,Surge protection 4kV with necessary elmax connector block and internal wiring etc. as required.The rate should be inclusive of 1. pole 2. Foundation bolt 3. Light fixture 4. 500mm Cross Arm(Preferred Make: Bajaj-BAJAJ ENXT P 36W WH PO PC SD_114113 or Equivalent). |
| 26 | Panel and Pole Foundation |
| 27 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 28 | All kinds of soil. |
| 29 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 30 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 31 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 32 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 33 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 34 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 35 | Taking out existing CC interlocking paver blocks from footpath/ centralverge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 36 | Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. Please Enable Macros to View BoQ information |