| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and for all lift as per direction of Engineer-in-charge by in charge - all kinds of soil |
| 2 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.- in cement mortar |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:5:10 (1 cement : 5 fine aggregate : 10 graded stone aggregate 40mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:3:6 (1 cement : 3 fine aggregate : 6 graded stone aggregate 20mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:2:4 (1 cement : 2 fine aggregate : 4 graded stone aggregate 20mm nominal size) |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:2:4 (1 cement : 2 fine aggregate : 4 graded stone aggregate 40mm nominal size) |
| 7 | Centering and shuttering including strutting propping etc and removal of form for - Suspended floors, roofs, landings, balconies and access platform |
| 8 | Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars Fe - 500D or more |
| 9 | Cement concrete flooring 1:2:4 (1 cement : 2 fine aggregate : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc .complete - 40mm thick with 20mm nominal size stone aggregate |
| 10 | Centring and shuttering including strutting, propping etc. and removal of form work for - foundations, footings, bases for columns |
| 11 | Centring and shuttering including strutting, propping etc. and removal of form work for - retaining walls, return walls, walls any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 12 | Providing and laying brick block of size 0.34 x 0.34 x 0.23 mts in C.M 1:4 (1 cement : 4 fine aggregate) using well burnt country bricks of class designation 35 for apron and revetment including levelling the bed, laying to the required levels , slop etc., complete. |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 fine aggregate) |
| 14 | 12mm cement plaster of mix -1:4 ( 1 cement : 4 fine aggregate) |
| 15 | Finishing walls with water proofing cement paint of required shade- Old work (one or more coats applied @ 2.20 kg /10 sqm) over priming coat of primer applied @ 0.80 litres/10sqm complete including cost of priming coat |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade- One or more coats on old work |
| 17 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade - one or more coats on old work |
| 18 | Demolishing R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 19 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. - Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) Please Enable Macros to View BoQ information |