| 1 | Dismantling brick work, tile, masonry or tile lining In cement |
| 2 | Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 3 | Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 4 | Disposal of dismantled Malba / Rubbish collected from UCB Kitckens and washrooms including all labour, loading, transportation, unloading into disposal area approx 2 Km lead within plant area , all required T&P up to clearance of site complete in all respects & as per directions of Engineer-in-charge. |
| 5 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below. |
| 6 | Removing of Doors to fix floor tiles, cutting/resizing of doors as per site requirement and fixing of these doors including accessories with chowkhats including cost of planning, screws, nails etc. complete in all respects. (Labour Charges Only) |
| 7 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. |
| 8 | 12.5 mm thick cement plaster 1:4 |
| 9 | 16mm thick cement plaster 1:4 in two coat work |
| 10 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement : 4 fine sand) including grouting the joints of tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 11 | Providing and laying matt finish/anti skid vitrified floor tiles in different sizes in light colour shades made using Soluble Salt Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on flooring skirting and dado laid with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 including grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 12 | Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. a) 20mm o/d |
| 13 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 14 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect a) C.P brass towel ring |
| 15 | P&F in position CP brass soap dish of approved make complete in all respect |
| 16 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B (a) 110mm o/d SWR UPVC pipe lines laid complete |
| 17 | 75mm o/d SWR UPVC pipe lines laid complete |
| 18 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. (a) For 110mm o/d pipes (i) Single Tee With Door |
| 19 | Elbow 90 Degree (All side socketed) |
| 20 | Coupler |
| 21 | P Trap/Floor Trap 110mm x 75mm |
| 22 | For 90mm o/d pipes (i) Single Tee With Door |
| 23 | Elbow 90 degree (all side socket) |
| 24 | Coupler |
| 25 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 26 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 27 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 28 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 29 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : (a) For fixed portion and chawkhats |
| 30 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 31 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side. |
| 32 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 33 | Preparation for plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish. |
| 34 | Providing & Fixing of restroom cubicles upto height 2000 mm with HDF board of Action Tesa or eqv. make including all accessories of Pure SS erection, cutting, fitting, jointing etc. complete in all respect to the entire satisfaction of Engg-in-charge. |
| 35 | Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 36 | Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) |
| 37 | Waterproofing of wet areas ( Concrete/ Masonary Surface ) and any water retaining structures such as swimming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionous coating ( DR. FIXIT FASTFLEX / Equivalent ) to provide tough film build-up and highly elastic film formation, which accommodates thermal movements so as to provide seamless coating without any joints to prevents water leakage. The scope of work also includes surface prepration and cleaning, washing and removing dust,dirt and loose particles from concrete / masonary surface complete in all respects. Please Enable Macros to View BoQ information |