| 1 | Civil Works: -Earthwork in excavation upto 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in all kinds of soil including moorum, hard stony earth, earth mixed with boulders etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. |
| 2 | Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. |
| 3 | Providing & laying P.C.C. of prop.(1:4:8) in F & P, fountain, pathway toe wall, fountain base, base of column using 40mm nominal size down graded, screend, washed hard black cursher broken granite metal of approved quality & from approved quarry including laying in the layers hoisting, lowering, laying, watering and curing etc. complete to the requaired levels including cost, conveyance, royalty of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge. |
| 4 | Brick work with Fly Ash Brick in cement mortar ( 1:6) in Foundation & plinth with best quality bricks of size 25cm x 12cm x 8cm having minimum crushing strength from 75 Kg/cm2 wih dimension tolerance +2% immersing (well shaped, uniform in size) includes molding, chamfering, corbelling complete as per drawing, design and specification, watering and curing for 7 days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer-in-charge. |
| 5 | R.C.C. work of M-20 having minimum compressive strength of 200kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary as per direction of the Engineer-in-charge including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per direction of Engineer-in-charge (but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. |
| 6 | plinth bend |
| 7 | chajja |
| 8 | lintels |
| 9 | roof slab |
| 10 | Providing & fixing TOR Fe-500 D grade reinforcement bars of approved makes as per DTCN for RCC work of required diameter with straightening, cutting, bending, binding welding and joining (if necessary) and tying the grills and placing in position as required for R.C.C. work and providing fan hooks, hoisting, lowering and laying including cost, conveyance and taxes of tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all heights as per the drawing, design and direction of Engineer-in-charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.) |
| 11 | Brick work with Fly Ash Brick in cement mortar ( 1:6) in Super Structure with best quality bricks of size 25cm x 12cm x 8cm having minimum crushing strength from 75 Kg/cm2 wih dimension tolerance +2% immersing (well shaped, uniform in size) includes molding, chamfering, corbelling complete as per drawing, design and specification, watering and curing for 7 days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer-in-charge. |
| 12 | Providing 12mm thick cement plaster in cement mortar of proportion (1:6) over even surface of brick work after racking out the joints finished smooth to proper line and plumb, watering, curing for 7 days with cost, conveyance, royalties, of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. |
| 13 | Providing 6mm thick cement plaster in cement mortar of proportion (1:4) over even surface of RCC surface finished smooth to proper line and plumb, watering, curing for 7 days with cost, conveyance, royalties, taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. |
| 14 | Providing 25mm thick grading plaster in C.C. (1:2:2) laid in proper slope over terrace roof slab by using two part of sand, one part of cement and two parts of 6mm size black hard crusher broken granite chips with addition of water proofing compound of approved quality to be mixed with specified ratio including watering, curing, cost, conveyance, royalties, taxes of all materials, cost of all labour, T&P etc. complete as required for the finished item of work as directed by the Engineer-in-charge. |
| 15 | Supply, fitting and fixing of ceramic tiles in floors treads or steps and landing over 25mm thick bed of C.M. 1:1 (1 cement : 1 sand) jointed with neat cement slurry mixed with pigment to match the shades on the tiles etc. complete including cost of all materials, labour etc. all complete as required for the work and direction of Engineer-in-charge. |
| 16 | Fixing tiles/Marbles in dados skirting and risers of step on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete.(Glazed wal tile) |
| 17 | Providing & applying Two coat weather coat of exterior grade of approved make and shade an even finished surface over a coat of primer at all height with all scaffolding and staging charges including cost, conveyance of all materials and cost of all labour, sundries and T&P etc. required for the work complete as directed by the Engineer in charge. |
| 18 | Providing & applying Two coat weather coat of interior grade of approved make and shade an even finished surface over a coat of primer at all height with all scaffolding and staging charges including cost, conveyance of all materials and cost of all labour, sundries and T&P etc. required for the work complete as directed by the Engineer in charge. |
| 19 | Supplying, fitting and fixing of SS doors with shutters as per specification all etc. complet as per direction of Engineer in charge and specification as mentioned in the analysis of estimate. |
| 20 | Supplying, fitting and fixing properly as per approved drawing and design and specification of M.S. grill in windows, the cost of hardware such as screws and welding if necessary to the windows as required for the work including cost, conveyance of all materials, required screws, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge . |
| 21 | Painting Two coats of synthetic enamel paint over iron surface over a coat of primer of approved quality, sand papering, polishing the surface including cost, conveyance of all materials cost of all labour, T&P etc. as required for the work complete as per direction of Engineer in charge. (Paints and primer will be supplied by the contractor). |
| 22 | Supply and installation of ,Jali,Dome & as well as Solid GFRC (Glass Fiber Reinforced Concrete) mouldings for columns, cornices, and other architectural elements including all cost, taxes of all materials, labour, T&P etc. required for the complete in all respect. |
| 23 | P.H. Installations : -Supply and fixing of 1000 ltr. capacity Rotational moulded Polyethylene cylindrical vertical water storage tanks conforming to IS:12701-1996 in 1st floor over a staging of 60 cm with required Fly ash brick work, RCC beam and slab as per drawing and specification including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixding Ball Valve etc. including hoisting up to a height of 5 meters above ground level and placing the tank to the required position etc. all complte as per specification and direction of Engineer-in-charge. (Double Layer) |
| 24 | Supplying all materials, labours, T&P and fitting and fixing of the following size of UPVC pipe SC-80 confirming to IS 13592 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance of all materials all complete as per PH specification and direction of Engineer-in-charge. |
| 25 | 50mm dia |
| 26 | 25mm dia |
| 27 | Supplying all materials,labours,T&P for cutting holes through existing brickwork including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. |
| 28 | 25 mm dia |
| 29 | 20 mm dia |
| 30 | 40 mm dia |
| 31 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge |
| 32 | 25 mm dia |
| 33 | 20 mm dia |
| 34 | Supplying all materials, labor T&P and fitting and fixing brass screw down stop cocks / ball valves of the following size as per specification all complet. |
| 35 | 25 mm dia pvc Ball valve |
| 36 | Supplying all materials, labor T&P and cutting holes and grooves through existing brick workk,in RCC floor,roof upto 19 cms thickwall for taking GI / PVC pipes and fittings and making good to the damages to leak proof all complet. |
| 37 | 250 mm thick wall |
| 38 | RCC slab upto 19 cms thick |
| 39 | grrove cutting |
| 40 | Supplying all materials,labour and T&P for constructing Inspection chamber of size 0.75 x 0.75 x 0.45m with R.C.C. top slab in M25 mix with foundation concrete (1:2:4 ) inside plaster 12mm. thick with cement mortar (1:3) finished with neat cement punning, 12mm. thick out side plaster (1:3),brick work with flyash bricks with crushing strength not less than 75kg/sqcm. in cement mortar (1:3) finished smooth complete as per specification and direction of Engineer-n-charge. |
| 41 | Supplyng all materials, labour, T&P for construction of 250mm x 250mmx675 mm size C.I Gully trap chamber by F.A bricks masonry,CM (1:4), CP (1:3) with 150mm x 150mm PVC grating including labour and materials for fitting and fixing 100mm dia square mouth PVC gully trap with supply of all jointing materials and encasing the gully trap with a block of C.. (1:3:6) with 25mm size hard stone metal all complete with providing and fixing of 250mm x 250mm precst RCC cover as per approved design and specification and as per instruction of the EIC including cost, conveyance, taxes of all materials to site complete and as per the direction of Engineer-in-charge. (Square mouth gully trap chamber with RCC cover) |
| 42 | Construction of Septic tank (Detail estimate enclosed and as per analysis) |
| 43 | Supplying all materials, labor T&P and laying in trenches / fixing to walls with nails, bobbins and wooden plugs for UPVC SWR pipes and fittings of approved make including jointing and testing all complet. |
| 44 | 110 mm OD PVC SWR pipe s/s type B |
| 45 | 75 mm OD PVC SWR pipe |
| 46 | 110 mm PVC P trap |
| 47 | 110 mm PVC door tee |
| 48 | 110 mm PVC plain tee |
| 49 | 110 mm PVC plain bend |
| 50 | 111 mm PVC door bend |
| 51 | 110 mm PVC cowl |
| 52 | 110 mm PVC offset bend |
| 53 | 90 mm PVC nahani trap |
| 54 | 75 mm PVC door tee |
| 55 | 75 mm PVC plain tee |
| 56 | Supplying all materials, labour and T&P and providing and laying in trenches cement concret 1:4:8 with 40 mm size granite metal in bedding for PVC puipe of the following dia including curing as per direction of E I C all complete. |
| 57 | Type B-1 standard bedding in haunching |
| 58 | Supplying all materials, labor T&P and fitting and fixing of following sanitary installation as per P H specifications all complet. |
| 59 | EWC with P trap with seat cover |
| 60 | 550 x 400 mm Wash hand basin |
| 61 | 15 mm size C P bib cock short body 2 in 1 |
| 62 | 15 mm size C P anglular stop cock |
| 63 | 15 mm size C P pillar cock |
| 64 | 20 mm x 600 mm size Cromium brass plate towel rail |
| 65 | C P towel ring |
| 66 | C P soap holder |
| 67 | 10 ltr capacity L L flushing cistern |
| 68 | 15mmx 450 mm PVC connection pipe |
| 69 | 32mmx 600mm PVC waste pipe |
| 70 | 32 mm CP waste coupling |
| 71 | 15 mm size C P flange small |
| 72 | 15mm x 50 mm CP extension piece |
| 73 | 125 mm CP grating |
| 74 | Fixing 600mm x 450mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification. |
| 75 | Fixing of Health Fuset with 15mm or 20mm inlet including polishing all complete as per specification. |
| 76 | White vitreous china clay half stall urinal flat back 580x380x350 mm(Magnum type) |
| 77 | Electrical Works: -Recessed/surface wiring to light point/fan point/ Exhaust fan point with 1.5 Square mm FR PVC insulated single core multistranded copper conductor of ISI marked with 20mm dia. non-metallic PVC flexible conduit with 5 Amp, 25 on MS box having front bakelite cover of suitable size, MS box with 1.5 Sq.mm FR PVC insulated single core multistranded copper conductor as earth wire including all accessories and connection as per direction of Engineer-in-charge. |
| 78 | Light point. |
| 79 | Fan Point |
| 80 | Supply and fixing of Exhaust Fan. |
| 81 | Supply and fixing of 6Amp Plug Point. |
| 82 | Supply and fixing of 20Watt LED Tube light. |
| 83 | Supply and fixing of 10W LED bulk head fitting. |
| 84 | Supply and fixing of 4Way SPN DB. |
| 85 | Supply and fixing of 40Amp DP MCB. |
| 86 | Supply and fixing of 10Amp SP MCB. |
| 87 | Recessed submain wiring along with earth wire of PVC insulated single core multistandard copper ISI Marked conforming to IS 694/1990 in 20mm Dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC Conduit as required. |
| 88 | 2 x 2.5Sqmm+ 1 x 1.5Sqmm |
| 89 | Supply and laying of 2x10mm2 Al.Ar. U.G cable. |
| 90 | Supply and Laying of 40mm HDPE pipe for laying of Cable. |
| 91 | Cable trenching in all type of soil excepting rocky soil including excavation of earth, brick laying and filling of sand and loose earth to the original ground level with surface dressing after laying 1no 1.1 KVPVC insulated PVC sheathed armoured cable removal of surplus earth to a lead up to 5km. |
| 92 | Supply and fixing of Standard earthing. Please Enable Macros to View BoQ information |