| 1 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 to 3.0 m.) by Manual Means. |
| 2 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, withwith Ordinary Concrete mixer, etc. complete. With fine aggregate (Crushed sand V.S.I. Grade). |
| 3 | Providing and laying in situ/ Ready Mix cement concrete M-20 of trap/ granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with Ordinary Concrete mixer etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). |
| 4 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). |
| 5 | Carting away the debris out of marketyard premises (15K.M.) |
| 6 | Providing and fixing in position TMT FE -500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 7 | Dismantling stone masonry in lime or cement mortar including stacking the materials as directed with all leads, lifts complete. |
| 8 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm. thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 9 | Testing Charges for conducting CONCRETE CompressiveStrength OF Cement Concrete Cube (Set of 3 cubes) test. |
| 10 | Testing Charges for conducting Concrete Mix Design (Withall Tests on basic materials). |
| 11 | Testing Charges for conducting STEEL BAR TESTINGUpto 16 mm (Set of 3 Bars) Please Enable Macros to View BoQ information |