| 1 | Supplying and erecting RSJ pole 125*70mn 8m |
| 2 | Supplying and erecting M.S. angle 50*50*6mm |
| 3 | Supplying and erecting M.S. Flat 50*6 |
| 4 | Supplying and erecting AAC(Ant) 50 Sqmm aluminium conductor |
| 5 | Supplying and erecting AAC(Gnt) 25 Sqmm aluminium conductor |
| 6 | Supplying and erecting LT stay Set |
| 7 | Supplying and erecting LT stay wire(7/3.15mm, 10SWG) |
| 8 | Supplying and erecting LT shackle Hardware |
| 9 | Supplying and erecting LT shackle Insulator |
| 10 | Supplying and erecting LT stay insulator |
| 11 | Supplying and erecting G.I. wire 8 SWG/6SWG |
| 12 | Supplying and erecting LT Earthing set |
| 13 | Supplying and laying LT PVC 2 Core 16 Sqmm armoured Cable |
| 14 | Removing of RSJ Pole 8 Mtr |
| 15 | Removing of PSC Pole 8 Mtr |
| 16 | Dismentling of LT line |
| 17 | Bunch Conductor |
| 18 | AB Switch |
| 19 | Supplying and erecting RSJ pole 125*70mn 9m |
| 20 | PVC Bobin |
| 21 | Joint Kit HT |
| 22 | Joint Kit LT |
| 23 | Dismantling the existing pole above 6 m height (Octagonal and other decorative) with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level |
| 24 | Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). |
| 25 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing orany other purpose). |
| 26 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical GI pole). |
| 27 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). |
| 28 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole). |
| 29 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal /conical GI pole) |
| 30 | Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixingprovided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). |
| 31 | Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast). |
| 32 | Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 20 m raising lowering high mast) . |
| 33 | Making M- 20 cement concrete foundation suitable by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 25 m high mast). |
| 34 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 35 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 36 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 37 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 38 | Supplying & erecting single phase, 240V, street light control panel up to the max load of 6kW, SPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/ CC foundation. |
| 39 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 40 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 41 | Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 42 | Providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 43 | Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 44 | Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 45 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 46 | Supplying & erecting four pole ON LOAD change over switch, 415V, 63A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. |
| 47 | AB Cable Dead end clamp |
| 48 | AB Cable suspension clamp |
| 49 | AB Cable peircing connector |
| 50 | I Hook AB Cable |
| 51 | J Bolt (8m octagonal pole) |
| 52 | J Bolt (9m octagonal pole) |
| 53 | J Bolt (12.5m octagonal pole) |
| 54 | J Bolt (16m octagonal pole) |
| 55 | J Bolt (20m octagonal pole) |
| 56 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 57 | Making trench in Soft soil having 0.75m depth and minimum 0.3m width for laying provided cables up to voltage level of 1.1kV complete as per specification no. CW-EXN-CTR |
| 58 | Making trench in Hard murum/Tar road having 0.75m depth and minimum 0.3m width for laying provided cables up to voltage level 1.1kV cable complete as per specification no. CW-EXN-CTR |
| 59 | Making trench in Soft soil having 0.9m depth and minimum 0.3m width for laying provided cables of voltage range 3.3kV to 11kV complete as per specification no. CW-EXN-CTR |
| 60 | Making trench in Hard murum/Tar road having 0.9m depth and minimum 0.3m width for laying provided cables of voltage range 3.3kV to 11kV complete asper specification no. CW-EXN-CTR Please Enable Macros to View BoQ information |