| 1 | Cleaning of choked sewer lines of 100mm dia of any depth manually or through mechanical appliances and making sewer line functional, complete including working under foul condition and depositing the sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM distance complete all as specified and directed. |
| 2 | Cleaning of choked sewer lines of 150mm dia of any depth manually or through mechanical appliances and making sewer line functional, complete including working under foul condition and depositing the sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM distance complete all as specified and directed. |
| 3 | Cleaning of choked sewer lines of 200mm dia of any depth manually or through mechanical appliances and making sewer line functional, complete including working under, foul condition and depositing the sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM distance complete all as specified and directed. |
| 4 | Cleaning of choked sewer lines of 300mm dia of any depth manually or through mechanical appliances and making sewer line functional, complete including working under, foul condition and depositing the sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM distance complete all as specified and directed |
| 5 | Desludging of existing manholes of depth upto 1.50 mtr filled with sludge by means of manually or through mechanical appliances complete including working under foul condition and depositing and removal of sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 KM but not exc 2 KM complete all as specified and directed |
| 6 | Desludging of existing manholes of depth upto 1.50 mtr and not exc. 3.00 mtr filled with sludge by means of manually or through mechanical appliances complete including working under foul condition and depositing and removal of sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 KM but not exc 2 KM complete all as specified and directed |
| 7 | Desludging of existing manholes of depth more than 3.00 mtr filled with sludge by means of manually or through mechanical appliances complete including working under foul condition and depositing and removal of sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 KM but not exc 2 KM complete all as specified and directed |
| 8 | Cleaning and desludging by pumping out sludge water by septic tank/manholes and other locations cleaning truck i.e. Honey Sucker (The capacity of the truck is 6,000 litres) from existing chocked /blocked locations including taking out all sediment sand, dirt ash, grease fibre or vegetation, foreign materials etc from any depth and size of manholes/septic tanks including removing of sludge to distance exc. 3.00 Km but not exc. 5.00 Km away and buried under ground complete all as specified and directed |
| 9 | Cleaning of lines of any dia using mechanical method means where manual celaning is not possible and depositing and removal of sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM complete all as specified and directed |
| 10 | Cleaning of choked WC in ground floor manually or mechanical upto first man holes and making functional including working under foul condition complete all as specified and directed. Note : The rates quoted are deemed to be included opening of access door and closing etc as required at site. |
| 11 | Description same all as per item No 10 here-in-before but of WC in other than ground floors. |
| 12 | Cleaning of floor trap / Nahani trap / gully trap upto first manhole complete all as specified and directed. Note : The rates quoted are deemed to be included of access door and closing all as specified and directed . |
| 13 | Excavation in trenches n.exc 1.50 mtr wide and n. exc 1.50 mtr depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 Sqm on plan & n. exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed |
| 14 | Excavation in trenches not exc. 1.50 mtr wide for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc. 10 Sqm on plan exc. 1.5m and not exc. 3.00m in depth and getting out in soft/loose soil complete all as specified and directed |
| 15 | Removal of excavated material (soil) to a distance n. exc 50 mtr and depositing where directed at a level n. exc 1.50 mtr above the starting point complete all as specified and directed |
| 16 | Returning filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in soft/loose soil complete all as specified and directed |
| 17 | S&F DWC pipe class SN8 (double wall corrugated pipe of structural wall polyethelene piping systems) of 100mm internal dia (with coupler and elastomeric rubber sealing ring) with non smooth external annular corrugated and smooth internal surfaces (double wall) for non pressure underground sewerage and drainage application conforming to IS : 16098-2013 including all materials, labour, T&P required for proper completion of work complete all as specified and directed |
| 18 | M&L for 150mm bore salt glazed stoneware drain pipe grade ‘A’ conforming to IS 651-1972 laid in trenches and jointed in CM 1:1 complete all as specified and directed |
| 19 | S&F DWC pipe class SN8 (double wall corrugated pipe of structural wall polyethelene piping systems) of 150mm internal dia (with coupler and elastomeric rubber sealing ring) with non smooth external annular corrugated and smooth internal surfaces (double wall) for non pressure underground sewerage and drainage application conforming to IS: 16098-2013 including all materials , labour, T&P required for proper completion of work complete all as specified and directed |
| 20 | M&L for Reinforced concrete pipes, class NP3 200mm bore, laid and jointed with collars complete all as specified and directed |
| 21 | M&L for cement concrete aggregate bed to drain pipe 150 mm dia including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:4:8 type D 2 using 40mm graded stone aggregate complete all as specified and directed |
| 22 | Cutting into existing man holes for connecting new drains making good to pipes and rendering cutting out existing benching for and forming branch channel (1/2 round or ¾ in section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) surface smooth finished and reforming benching as required for internal dia of pipe 100mm complete all as specified and directed |
| 23 | Cutting into existing man holes for connecting new drains making good to pipes and rendering cutting out existing benching for and forming branch channel (1/2 round or ¾ in section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) surface smooth finished and reforming benching as required for internal dia of pipe 150mm complete all as specified and directed |
| 24 | Demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 25 | M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in manhole covers including necessary form work set in CM 1:4 complete all as specified and directed |
| 26 | M&L for mild steel TMT bars 8mm dia and over cut to length , bent to shape required including cranking bending etc and binding with mild steel wire (annealed ) not less than 0.90mm dia as in reinforcement complete all as specified and directed |
| 27 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed |
| 28 | M&L for cement concrete 1:4:8 , type D-2 using 40 mm graded stone aggregate as in fdn , filling and mass concrete complete all as specified and directed |
| 29 | M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) in surface channels and drain complete all as specified and directed |
| 30 | M&L for providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in copings, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed |
| 31 | M&L for 75mm thick cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection complete complete all as specified and directed |
| 32 | M&L for chequered cement concrete tile 300mm x 300mm x 20 to 25mm thick with grey cement and pigment set jointed and pointed in neat cement siurry over screed bed or bedding layer 15 mm thick in CM (1:6) in floor complete all as specified and directed |
| 33 | Extra for farming fair finished drain or channel 30 cm inner girth in cement, concrete, using extra cement, including forms, moulds, mitered/stopped end etc complete all as specified and directed |
| 34 | Extra for farming fair finished drain or channel 15 cm inner girth in cement, concrete, using extra cement, including forms, moulds, mitered/stopped end etc complete all as specified and directed |
| 35 | Taking down PVC pipe of any size or pattern including all fitting head, shoe, band, swan neck etc complete all as specified and directed |
| 36 | S&F PVC (SWR) pipes, Single socketed, in any length with rubber ring joints, fixed to walls 110mm bore complete all as specified and directed |
| 37 | S&F PVC (SWR) pipes, Single socketed, in any length with rubber ring joints, laid in trenchs or floor 110mm bore complete all as specified and directed |
| 38 | S&F PVC (SWR) pipes, Single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore complete all as specified and directed |
| 39 | S&F PVC (SWR) pipes, Single socketed, in any length with rubber ring joints, laid in trenchs or floor 75 mm bore complete all as specified and directed |
| 40 | S&F PVC (SWR) bends any radius, 110mm bore complete all as specified and directed |
| 41 | S&F PVC (SWR) bends any radius, 75 mm bore complete all as specified and directed |
| 42 | S&F PVC (SWR) Junnction single (T) equal or unequal 110mm dia complete all as specified and directed. |
| 43 | S&F in repair PVC (SWR) floor trap plain with grating in cluding jointing with solvent cement 75/100mm dia complete all as specified and directed |
| 44 | S&F in repair PVC (SWR) nahani trap plain with grating in cluding jointing with solvent cement 75/100mm dia complete all as specified and directed |
| 45 | S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed |
| 46 | Demolition of brick work built in cement mortar or cement lime mortar complete all as specified and directed |
| 47 | M&L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc 6 m mean radius built in cm (1:6) complete all as specified and directed |
| 48 | Description same all as per item Serial No 47 here-in-before but except old size sub class 'B' bricks.Note : Old bricks retrieved from demolition shall be re-used. |
| 49 | M&L for brick work with fly ash old size bricks straight or curved on plan exc 6 m mean radius built in cm (1:6) complete all as specified and directed |
| 50 | M&L for brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:6) complete all as specified and directed |
| 51 | M&L for 15mm thick rendering on fair faces of brick work or concrete surface with cm (1:4) finishing fair and even complete all as specified and directed |
| 52 | Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 53 | M&L for two coat cement base paint on wall over one coat cement primer including preparing new or old plastered surfaces complete all as specified and directed |
| 54 | M&L preparing old painted brick or conc surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed |
| 55 | S&F Machine pressed precast conctete interlocking paver block coloured any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment complete including 25 mm thick sand cushion complete all as specified and directed |
| 56 | S&F in repair vitreous china squatting pan, ‘Orissa’ pattern, of size 580 mm x 440 mm white with integral foot rest complete including p or s trap and provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe etc complete all as specified and directed |
| 57 | S&F in repair vitreous china wash down water closed pan (Pedestal pattern) with 'P' or 'S' trap white, including connection to trap and cistern, flush pipe including white plastic water closet seat cover, closed pattern with flat bottom & cover and aluminium anodised hinging device and making good disturbed surface of floor complete all as specified and directed |
| 58 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 59 | M&L for Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including rendering 10mm thick in cement mortar 1:4 finished rough to receive wall tiles etc complete all as specified and directed. |
| 60 | M&L for non skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 61 | M&L for first or premium quality heavy duty pavement tiles 300mm x 300mm x 7-8mm / 400mm x 400mm x 7-8mm thick coloured for floor/pavement etc & jointed in neat cement slurry and pointed with white cement fixed with colour pigment to match colour of tiles including 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 62 | M&L for water proofing treatment to sunken floor with polymeric water proofing membrane after cleaning the surface by wire brushes,brooming,removing dust and applying treatment as under complete all as specified and directed :-(a) M&L Plastering 15mm thick in CM 1:4 using 100% coarse sand on roof including WPC 3% by weight of cement.(b) Applying a coat of bitumen primer conforming to IS-3384 - 1965 @ 0.50 lit/Sqm and allow to dry.(c) Applying one coat of hot blown bitumen grade 85/25 as per IS-702-1988 @ 1.20 Kg/Sqm of each coat applied over primer incl cleaning of surfaces .(d) Supply and laying polymeric water proofing membrane of 3mm thick with consists of a centre core 90 micron thickness molecular high density polyethylene film protected on both sides with a high quality polymeric asphaltic mix will be protected on both sides with20 micron HMHDPE film, weight not less than 3.00 Kg/Sqm over area including overlapping as per manufacturers instruction.(e) M&L for for applying a tack coat of hot blown bitumen as per IS 702-1988 applying evenly on top of polymeric water proffing membrance @ 1.20 Kg/sqm. (f) M& L for blending of course dry sand @ 0.75 KG/Sqm |
| 63 | S&F in repair PVC syphonic action type flushing cistern 10 litre capacity with complete internal kit including bracket fixed in repair (including flushing pipe complete) complete all as specified and directed |
| 64 | S&F in repair standard stainless steel grating doom round 125mm size with waste hole (minimum wt 40 gms) complete all as specified and directed. |
| 65 | S&F Moc stainless steel Gde-304 Oil and grease trap of sie 900 x 900 x 900mm thickness 1.8mm basket size 345 x 325mm & trap 75mm including all necessary connections upto first manhole & accesories for disposing waste water to nearbuy drain/chamber through drain pipe etc including cutting hole in brick wall, excavation and PCC (1:3:6) work if reqd and making good to the surface complete all as specified and directed. |
| 66 | S&F Moc stainless steel Gde-304 Oil and grease trap of sie 750 x 450 x 450mm thickness 1.6mm basket size 200 x 200mm & trap 50mm including all necessary connections upto first manhole & accesories for disposing waste water to nearbuy drain/chamber through drain pipe etc including cutting hole in brick wall, excavation and PCC (1:3:6) work if reqd and making good to the surface complete all as specified and directed |
| 67 | Cleaning and removing all scale and dirt etc from water storage tank of 250 to 500 ltrs capacity and from mouth of curculating pipes etc and writing date of cleaning of the tank with paint 75 mm height in DD/MM/YY patern and refixing the cover after cleaning complete all as specified and directed |
| 68 | Cleaning and removing all scale and dirt etc from water storage tank of 500 to 1000 ltrs capacity and from mouth of curculating pipes etc and writing date of cleaning of the tank with paint 75 mm height in DD/MM/YY patern and refixing the cover after cleaning complete all as specified and directed |
| 69 | S&F in repair overhead PVC water tank cover of capacity 500/1000 ltrs including fixing the cover with PVC hinges and locking system to the existing tank complete all as specified and directed. |
| 70 | S&F in repair ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (minimum weight 210 gms) complete all as specified and directed. |
| 71 | S&F in repair ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 15 mm bore (minimum weight 142 gms), complete all as specified and directed. |
| 72 | S&F in repair ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 25 mm bore (minimum weight 142 gms), complete all as specified and directed. |
| 73 | Taking up or down 15mm bore pipes steel tubing and connections including cleaning for refixing or removing to store or removing from site complete all as specified and directed. |
| 74 | Taking up or down 20mm bore pipes steel tubing and connections including cleaning for refixing or removing to store or removing from site complete all as specified and directed. |
| 75 | Taking up or down 25mm bore pipes steel tubing and connections including cleaning for refixing or removing to store or removing from site complete all as specified and directed. |
| 76 | S&F 15mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 77 | S&F 20mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 78 | S&F 25mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 79 | Refixing old steel tubing and connection in new or old position in wall/ceiling/floor etc bore of pipe 15mm dia complete all as specified and directed. |
| 80 | Refixing old steel tubing and connection in new or old position in wall/ceiling/floor etc bore of pipe 20mm dia complete all as specified and directed |
| 81 | S&F in repair rotational moulded,multilayer HDPE water storage tank of 500 ltrs capacity white colour three layer (Cylindrical vertical with closed top) ISI marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia PTMT float valve epoxy coated Aluminium rod with high density plastic float ball( of minium weight 210 gms) and refixing of inlet, outlet & overflow pipe etc, complete all as specified and directed |
| 82 | S&F in repair rotational moulded,multilayer HDPE water storage tank of 1000 ltrs capacity white colour three layer (Cylindrical vertical with closed top) ISI marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia PTMT float valve epoxy coated Aluminium rod with high density plastic float ball( of minium weight 210 gms ) and refixing of inlet, outlet & overflow pipe etc, complete all as specified and directed |
| 83 | S&F 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed |
| 84 | S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed |
| 85 | S&F 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed |
| 86 | M&L uprooting of plants/ trees growth on wall/ drains/ roof surfaces etc in a skilled and careful manner using appropriate tools and means and without causing any damage to the adjoining part. The exposed surfaces of wall will be coated with a paste made from ammonium sulphate crystals or with tree killer chmical available in the market. In this condition the root system to be left to absorb and die. The rate for making good the existing wall surfaces damaged during the uprooting of the tree is deemed to be included in the rate quoted by the contractor. |
| 87 | M&L preparation of existing new or old plaster surfaces including removal of existing treatment and applying two coat of Dr. fixit sure ceal damp proof chemical or Smartcare hydroloc water proofing of make Asian on plaster surfaces as specified by the manufacturer complete all as specified and directed |
| 88 | Schedule of Credit (MINUS) Rs. 67,915.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum Please Enable Macros to View BoQ information |