| Sl. No. | Item Description |
| 1 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 2 | 100 mm |
| 3 | 150 mm |
| 4 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. |
| 5 | HDPE PE-80 PN-10 |
| 6 | 90 mm dia |
| 7 | 110 mm dia |
| 8 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method , including transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. |
| 9 | HDPE PE-80 PN-6 |
| 10 | 63 mm dia |
| 11 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil |
| 12 | Demolishing cement concrete manually/ by mechanical means including disposal of MATERIAL within 50 metres lead as per direction of Engineer-in-charge. |
| 13 | 1: 3: 6 or richer mix. |
| 14 | Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
| 15 | Bituminous courses |
| 16 | Granular courses |
| 17 | Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work. |
| 18 | M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 19 | Removing & Re-fixing of Precast concrete interlocking blocks by manual, stacking of serviciable & non serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block against damaged, including all lead and lift as per Technical specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) |
| 20 | 80 mm thick |
| 21 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. |
| 22 | MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet) |
| 23 | MS pipe specials above 600mm dia (with minimum 6.3mm thickness sheet) |
| 24 | Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 25 | Class PN 1.0 |
| 26 | 80 mm dia |
| 27 | 100 mm dia |
| 28 | 150 mm dia |
| 29 | SITC of Bulk Flow Meter with removable mechanism class \\"B\\" confirming to ISO:4064:2005/IS 2373 of approved make of following dia sized pipelines and specifications complete: media: water(clear) , temp.50 degree, pr. rating PN16, protection type IP-68, body material : IS-210 Gr. FG-200, Accuracy class : Class B ( +2% @ Nominal flow rate), Magnetic drive, Dry Dial, Epoxy Powder coated , Pulse out option, Anti-magnetic protection including all materials and making connection with existing pipeline required for bulk Flow meter including cutting the existing pipline etc. complete in all respect as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 30 | BFM 80 mm |
| 31 | BFM 100 mm |
| 32 | BFM 150 mm |
| 33 | BFM 200 mm |
| 34 | BFM 300 mm |
| 35 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 36 | Manually Operated CI Sluice valve of Class PN-1.0 |
| 37 | 80 mm HW |
| 38 | 100 mm HW |
| 39 | 150 mm HW |
| 40 | 200 mm HW |
| 41 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 42 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 |
| 43 | 80 mm dia |
| 44 | 100 mm dia |
| 45 | 125 mm dia |
| 46 | 150 mm dia |
| 47 | 200 mm dia |
| 48 | 250 mm dia |
| 49 | 300 mm dia |
| 50 | 350 mm dia |
| 51 | 400 mm dia |
| 52 | 450 mm dia |
| 53 | P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.\\"B\\" Class |
| 54 | 15mm dia nominal bore |
| 55 | 20 mm dia nominal bore |
| 56 | 25mm dia nominal bore |
| 57 | 32mm dia nominal bore |
| 58 | 40mm dia nominal bore |
| 59 | 50mm dia nominal bore |
| 60 | 65mm dia nominal bore |
| 61 | Making connection of G.I. distribution branch with G.I. main including all fitting. |
| 62 | Upto 25mm dia |
| 63 | Beyond 25mm & upto 100mm dia |
| 64 | Labour Charges for making connection with proposed pipe line to existing pipe line of AC/ DI/ CI including dewatering etc. complete but excluding the cost of pipes, specials, joints etc as directed bysite engineer for following dia. (Earthwork to be measured and paid separately) |
| 65 | 80-200 mm dia |
| 66 | 250-500 mm dia |
| 67 | Labour Charges for making connection with proposed pipe line to existing pipe line of PVC/ HDPE/ GRP including dewatering etc.complete but excluding the cost of pipes, specials, joints etc as directed by site engineer for following dia. (Earthwork to bemeasured and paid separately) |
| 68 | 75-200 mm dia |
| 69 | Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and 2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 70 | 5.5 KW (7.5 HP) |
| 71 | 7.5 KW (10 HP) |
| 72 | 9.3 KW (12.5 HP) |
| 73 | 11.0 KW (15 HP) |
| 74 | 15.0 KW (20 HP) |
| 75 | SITC Star delta starter type LT panle of following rating: all switchgears are of PHED approved makes, CRCA sheet of panel enclosures is of TATA/Essar 1.6mm/2.0mm thck duly Elecrostatic powder coated with angke frame including other ancillaries (insulators, acrylic sheet, backlight sheet, Hardware, Wire Name Plates, Lugs, PVC Channel, MCB Channel, Lock, himg, Bidding, connectors, neutral links spiral, saddle & packing material) etc and 100A/125A, TPN, Aluminium Bus Bar with colour coated heat shrinkage sleeves complete as per technical specifications and as per direction of Engineer-in-charge |
| 76 | Star Delta Starter 7.5 KW (10.0 HP) : For 2 motors (1w+1s) I/C - MCB 63A, FP, 10 KA, C curve (1), Analog Voltmeter 96* 96mm (0-500V) (1) Volt Selector Switch (1) , Analog Ammeter 96*96mm (0-60A) (1) , Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow-1) (2), Indicating lights (Blue - 1) (1) , Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 32A , TP, 10 KA, C Curve (2) , Power Cont 18A TP AC3 Duty (2), 2 NO+2 NC Aux. Block(2), Thermal Overload Realy (7-10A) (2) , Control MCB 6A SP 10 KA C Curve (2) , Single Phase Preventer (2), Indicating Lights ( Red - 1, Green -1, Amber - 1) (6) Push Button 22.5 ( Red -1 , Green-1) (4) , Selector Switch 1 Pole, 2 Way (2) Capactior 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer (2) |
| 77 | Star Delta Starter 9.3 KW ( 12.5 HP) : For 2 Motors ( 1 w+1s) I/C- MCB 63A, FP, 10 KA C Curve (1), Analog Voltmeter 96*96mm (0-500V) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm (0-60A) (1) Amp. Selector Switch (1) , C.T 60/5A CL 1.0 5VA (3) , Indicating Lights (Red-1, Yellow-1) (2) , Indicating Lights (Blue -1 ) (1) , ControL MCB 6A SP 10KA C Curve (3) and O/G- MCB 40A ,TP , 10KA C Curve (2) , Power Cont 18A TP AC3 Duty (2) , 2 NO+2 NC Aux. Block (2) , Thermal Overload Relay (7-10A) (2) , Control MCB 6A SP 10 KA C Curve (2) , Single Phase Preventer (2), Indicating Lights ( Red - 1, Green -1, Amber - 1) (6) Push Button 22.5 ( Red -1 , Green-1) (4) , Selector Switch 1 Pole, 2 Way (2) Capactior 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer (2) |
| 78 | Star Delta Starter 11 KW ( 15 HP) : For 2 Motors ( 1 w+1s) I/C- MCB 63A, FP, 10 KA C Curve (1), Analog Voltmeter 96*96mm (0-500V) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm (0-60A) (1) Amp. Selector Switch (1) , C.T 60/5A CL 1.0 5VA (3) , Indicating Lights (Red-1, Yellow-1) (2) , Indicating Lights (Blue -1 ) (1) , ControL MCB 6A SP 10KA C Curve (3) and O/G- MCB 40A ,TP , 10KA C Curve (2) , Power Cont 25A TP AC3 Duty (2) , 2 NO+2 NC Aux. Block (2) , Thermal Overload Relay (9-13A) (2) , Control MCB 6A SP 10 KA C Curve (2) , Single Phase Preventer (2), Indicating Lights ( Red - 1, Green -1, Amber - 1) (6) Push Button 22.5 ( Red -1 , Green-1) (4) , Selector Switch 1 Pole, 2 Way (2) Capactior 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer (2) |
| 79 | Star Delta Starter 15 KW ( 20 HP) : For 2 Motors ( 1 w+1s) I/C- MCB 100A, TPN, 25 KA C Curve (1), Analog Voltmeter 96*96mm (0-500V) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm (0-60A) (1) Amp. Selector Switch (1) , C.T 100/5A CL 1.0 5VA (3) , Indicating Lights (Red-1, Yellow-1) (2) , Indicating Lights (Blue -1 ) (1) , ControL MCB 6A SP 10KA C Curve (3) and O/G- MCB 63A ,TPN , 25KA C Curve (2) , Power Cont 32A TP AC3 Duty (2) , 2 NO+2 NC Aux. Block (2) , Thermal Overload Relay (12-18A) (2) , Control MCB 6A SP 10 KA C Curve (2) , Single Phase Preventer (2), Indicating Lights ( Red - 1, Green -1, Amber - 1) (6) Push Button 22.5 ( Red -1 , Green-1) (4) , Selector Switch 1 Pole, 2 Way (2) Capactior 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer (2) |
| 80 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: |
| 81 | P.V.C.heavy duty, 15mm nominal bore. |
| 82 | P&F PVC storage tank ISI marked (IS: 12701) indicating the BIS license No), of approved make with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout pipe with plug & socket, including connections etc., complete of approved design: |
| 83 | 500 litres capacity |
| 84 | 1000 litres capacity |
| 85 | Fabrication & Fixing M.S. Stand of specified class of angle iron L-shaped of 50 mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the ground and all legs tied up with each other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank complete in all respect. |
| 86 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make |
| 87 | Gun-metal 15mm nominal bore. |
| 88 | Gun-metal 20mm nominal bore. |
| 89 | Gun-metal 25mm nominal bore. |
| 90 | Gun-metal 32mm nominal bore. |
| 91 | Gun-metal 40mm nominal bore. |
| 92 | Gun-metal 50mm nominal bore. |
| 93 | P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality: Horizontal |
| 94 | (a) 32mm nominal bore. |
| 95 | (b) 50mm nominal bore. |
| 96 | Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. |
| 97 | Nominal bore 150 mm dia. |
| 98 | Nominal bore 200 mm dia. |
| 99 | Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. |
| 100 | Nominal bore 150 mm dia. |
| 101 | Nominal bore 200 mm dia. |
| 102 | Add 30% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr . |
| 103 | Nominal bore 150 mm dia. |
| 104 | Nominal bore 200 mm dia. |
| 105 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes |
| 106 | 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) |
| 107 | 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) |
| 108 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. |
| 109 | 125 mm dia |
| 110 | 150 mm dia |
| 111 | 200 mm dia |
| 112 | Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended upto date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended upto date, along with clamping of submersible cable etc. complete in all respect. |
| 113 | 40 mm dia |
| 114 | 50 mm dia |
| 115 | Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. |
| 116 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. |
| 117 | Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 118 | Up to 2.0 KW |
| 119 | Above 2.0 KW |
| 120 | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 121 | Up to 5.5 KW (7.5 HP) & head up to 120 mtr. |
| 122 | Up to 5.5 KW (7.5 HP) & head above 120 mtr. |
| 123 | 7.5 KW (10 HP) & head up to 120 mtr. |
| 124 | 7.5 KW (10 HP) & head above 120 mtr. |
| 125 | 9.3 KW (12.5 HP) & head up to 120 mtr. |
| 126 | 9.3 KW (12.5 HP) & head above 120 mtr. |
| 127 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. |
| 128 | 32 mm dia |
| 129 | 50 mm dia |
| 130 | 65 mm dia |
| 131 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. |
| 132 | 3 core 4.0 Sq.mm |
| 133 | 3 core 6.0 Sq.mm |
| 134 | 3 core 10.0 Sq.mm |
| 135 | 3 core 16.0 Sq.mm |
| 136 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 137 | 10.0 Sq.mm, 4 core |
| 138 | 16.0 Sq.mm, 4 core |
| 139 | 25.0 Sq.mm, 3.5 core |
| 140 | 35.0 Sq.mm, 3.5 core |
| 141 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. |
| 142 | Above 5 HP and up to 10 HP |
| 143 | Above 10 HP and up to 15 HP |
| 144 | Above 15 HP and up to 20 HP |
| 145 | Above 20 HP and up to 30 HP |
| 146 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase upto 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply. |
| 147 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 148 | (a) 6.00 sqmm 2 core |
| 149 | (b) 10.00 sqmm 2 core |
| 150 | (a) 70.00 sqmm 3.5 core |
| 151 | (b) 120.00 sqmm 3.5 core |
| 152 | (c) 150.00 sqmm 3.5 core |
| 153 | Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 154 | One day & week reserve (Analog type ) |
| 155 | Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.Centrifugal Monoblock Pump set (Single Stage) |
| 156 | 7.5 KW (10 HP) |
| 157 | 11.0 KW (15 HP) |
| 158 | 15.0 KW (20.0 HP) |
| 159 | Providing, installation, testing and commissioning of Submerged Centrifugal Pump sets with motor 4 pole synchronised speed of 1500 rpm ( water immersed, dry air filled, class \\"F\\" insulated TEWC motor integrally mounted on volute casing pump sets for drinking water ) 3 phase, +/- 3%, 415 volt +/- 10%, along with suitable foundation/ installation device and with 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 160 | 22 KW |
| 161 | 30 KW |
| 162 | 37 KW |
| 163 | 45 KW |
| 164 | Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 165 | Discharge 51 to 60 LPS And Head 31 to 40 Mtr |
| 166 | Discharge 51 to 60 LPS And Head 41 to 50 Mtr |
| 167 | Discharge 91 to 100 LPS And Head 31 to 40 Mtr |
| 168 | Discharge 121 to 140 LPS And Head 31 to 40 Mtr |
| 169 | Rewinding of single phase/3phase submersible motor including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 170 | 2.0 H.P.to 3.0 HP |
| 171 | Above 3.0 HP to 5.0 HP |
| 172 | From7. 5 HP to 10.0 HP |
| 173 | Repairing of submersible pump of with replacement of broken impellers ,diffuser,bush/bearing set , oil seal complete with testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 174 | 2.0 H.P.to 3.0 HP |
| 175 | Above 3.0 HP to 5.0 HP |
| 176 | From7. 5 HP to 10.0 HP |
| 177 | Labour charges for installation of submersible motor pump set including lowering/ delowering of pipes, cables, accessories etc. in tube-well/ open well complete including T&P, transportation of tripod, chain pulley block & any other material required for this purpose complete in all respect. |
| 178 | Lowering only |
| 179 | Delowering only |
| 180 | Delowering and Lowering |
| 181 | Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover. |
| 182 | Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including MS/PP saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or ball valve (min. weight 165 gm) and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipe with fittings in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid separately. |
| 183 | For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. |
| 184 | Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. |
| 185 | Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. |
| 186 | Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm ISI marked PN16 SDR 7.4 (IS:15801:2008) PPR-C (Three layered) pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. |
| 187 | Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. |
| 188 | Nominal bore 125 mm dia. |
| 189 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr. |
| 190 | Supply of ERW M.S. black casing pipe ISI marked {IS:1239(Part-1:2004)} medium of following sizes at site of work. |
| 191 | 125 mm dia NB( Thickness of pipe 4.8 mm & mass of tube 16.40 Kg/m) |
| 192 | Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. |
| 193 | 125 mm dia nominal bore |
| 194 | Supply & installation of GI pipe 32 mm medium class “B” with pipe sockets (heavy duty). |
| 195 | Supply and installation of ISI marked India Mark II Hand pump set complete with cylinder & 15 connecting rods. |
| 196 | Supply and installation of ISI Marked India Mark II Hand pump set Extra-Deep (EDW) complete with cylinder and connecting rods. |
| 197 | EDWHP + 20 Connecting rod. |
| 198 | Supply and installation of ISI mark connecting rod as per departmental specifications. of 3 meter length. |
| 199 | Installation of India Mark II/III E.D. I & II hand pump set complete on existing platform. |
| 200 | Construction of 185 cm. dia platform as per approved design & drawing of UNICEF. |
| 201 | SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus. |
| 202 | 22 KW |
| 203 | 30 KW |
| 204 | 37 KW |
| 205 | 45 KW |
| 206 | 55 KW |
| 207 | 75 KW |
| 208 | 90 KW |
| 209 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \\"O \\"ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 210 | Class PN 1.6 |
| 211 | 150 mm dia |
| 212 | 250 mm dia |
| 213 | 300 mm dia |
| 214 | 350 mm dia |
| 215 | Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. |
| 216 | 100mm dia |
| 217 | 150mm dia |
| 218 | 200mm dia |
| 219 | 250mm dia |
| 220 | 300mm dia |
| 221 | 350mm dia |
| 222 | 400mm dia |
| 223 | 450mm dia |
| 224 | 500mm dia |
| 225 | 600mm dia |
| 226 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 227 | 200 Amp , 25kA, adjustable O/L & adjustable S/C setting |
| 228 | 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting |
| 229 | 400 Amp ,35 kA, adjustable O/L & adjustable S/C setting |
| 230 | Providing & Fixing of ISO certified company made TP&N 415 V AC-23A front handle operated switch disconnector fuse unit, cubical type, with metallic enclosure, as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 with HBC fuses including making connections with lugs, testing etc as required. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/work refer Annexure \\"A\\" attached with this BSR . |
| 231 | 250 A rating |
| 232 | 400 A rating |
| 233 | Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths DI K-12 standard specials with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately |
| 234 | Specials flanged DI K-12 |
| 235 | Upto 300mm dia |
| 236 | Above 300mm dia and upto 600mm dia Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail