| 1 | Supply and Installation of 1/2 Module Surface Mounting Plastic Boxes as per the detailed tender specification. |
| 2 | Supply and Installation of 3 Module Surface Mounting Plastic Boxes as per the detailed tender specification. |
| 3 | Supply and Installation of 6 Module Surface Mounting Plastic Boxes as per the detailed tender specification. |
| 4 | Supply and Installation of 12 Module Surface Mounting Plastic Boxes as per the detailed tender specification. |
| 5 | Supply and fixing One/Two Module front cover plate on existing modular metal/plastic boxes etc. as required and as per the detailed tender specification. |
| 6 | Supply and fixing 3 Module front cover plate on existing modular metal/plastic boxes etc. as required and as per the detailed tender specification. |
| 7 | Supply and fixing 6 Module front cover plate on existing modular metal/plastic boxes etc. as required and as per the detailed tender specification. |
| 8 | Supply and fixing 12 Module front cover plate on existing modular metal/plastic boxes etc. as required and as per the detailed tender specification. |
| 9 | Supply and Installation of 1 No 6A Switch on modular plate and termination of wires to the switches as per the detailed tender specification |
| 10 | Supply and Installation of 1 No 16A Switch on modular plate and termination of wires to the switches as per the detailed tender specification |
| 11 | Supply and Installation of 1 No 6A 3 Pin shuttered type Socket on modular plate and termination of wires to the switches as per the detailed tender specification. |
| 12 | Supply and Installation of 1 No 6/16A 3 Pin shuttered type Socket on modular plate and termination of wires to the switches as per the detailed tender specification, |
| 13 | Supply and Installation of 38 X 16 mm size of PVC Mini trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed tender specification. |
| 14 | Supply and Installation of 32 X 12mm size of PVC Mini trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed tender specification. |
| 15 | Supply and open installation of 150(W)X150(H)X80(D)mm, 1.6mm thick sheet MS Box as per the detailed tender specification. |
| 16 | Supply and open installation of 300(W)X300(H)X120(D)mm, 1.8mm thick sheet MS Box as per the detailed tender specification. |
| 17 | Supply and open instaln 1 Phase, 20A MC socket box with 20A DP MCB as per the detailed tender specification. |
| 18 | Supply and open installation of 16A 2P+E-DP Tempra plug and socket DBs with DP 16A MCB as per the detailed tender specification. |
| 19 | Supply Installation testing and commissioning of 6-32 Amps SP MCB (Type-C) on Distribution Boards as per the detailed tender specification. |
| 20 | Supply Installation testing and commissioning of the 6-32 Amps DP MCB (TYPE-C) on Distribution Boards as per the detailed tender specification. |
| 21 | Supply Installation testing and commissioning of 40-63Amps, DP MCB (TYPE-C) on Distribution Boards as per the detailed tender specification. |
| 22 | Supply Installation testing and commissioning of RCCB DP 25A sensitivity 30mA, TYPE AC on Distribution Boards as per the detailed tender specification. |
| 23 | Supply Installation testing and commissioning of RCCB DP 40A 30mA, TYPE AC on Distribution Boards as per the detailed tender specification. |
| 24 | Transportation, installation, testing and commissioning of the Recess mounted luminaires per the detailed tender specification. |
| 25 | Transportation, installation, testing and commissioning of the Surface mounted luminaires using ball & socket per the detailed tender specification. |
| 26 | Identification of fault and Replacement of 5A to 16A switches, telephone jacks, TV coaxial socket, 20A Modular motor starters, Modular plates of different sizes, plug tops in Flush/Concealed type MS switch boxes in labs and low bay areas as per the detailed tender specification. |
| 27 | Identification of fault and Replacement of 6/16/20/32 Amp, 250 volt, 50 Hz single pole /Double pole MCB in labs and low bay areas as per detailed tender Specification. |
| 28 | Identification of fault and Replacement of 415 volt, 50 Hz four/three pole MCB up to 63 Amps in labs and low bay areas as per detailed tender Specification. |
| 29 | Supply, installation, testing and commissioning of SDFU TPN 125A, DIN FUSES with 3Nos 125A HRC fuse links, Open Execution FN Sheet steel factory made enclosure with 3Nos Fuse links on MS frame work as per the detailed tender Specification.. (MS item will be measured separately).FN Cat No:SK90486 |
| 30 | Supply, installation, testing and commissioning of SDFU TPN 250A, DIN FUSES with 3Nos 250A HRC fuse links on MS frame work as per the detailed tender Specification. (MS item will be measured separately). |
| 31 | Supply and installation of 25 mm Dia 1.8mm, wall thickness Heavy Duty Hot Dip Galvanised ERW Conduits with 50mm deep junction boxes for Electrical & Communication System with required Solid Long Bends, Check Nuts, Nipples, Couplings, Reducers, Copper Clips, Copper Conductor, GI Wire etc, in Floor, Walls, Brick, Block Masonry, etc. including chasing & replastering as per the detailed tender specification. |
| 32 | Supply and installation of 32 mm Dia 1.8mm, wall thickness Heavy Duty Hot Dip Galvanised ERW Conduits with 50mm deep junction boxes for Electrical & Communication System with required Solid Long Bends, Check Nuts, Nipples, Couplings, Reducers, Copper Clips, Copper Conductor, GI Wire etc, in Floor, Walls, Brick, Block Masonry, etc. including chasing & replastering as per the detailed tender specification. |
| 33 | Attending to break down maintenance of minor nature occurring in kitchen equipment's such as loose connection/open circuit, changing of connecting cable etc as per the scope (Refer Sec VI (MNC), Clause No.15). Carrying out healthiness check of RCCB, MCB in TPN/SPN, 12/8/6 way DB including checking of earth continuity of the ditribution system as directed by the Engineer-in- charge |
| 34 | Attending to break down maintenance of minor nature occurring in kitchen equipment's such as loose connection/open circuit, changing of connecting cable etc as per the scope of work and detailed tender specification. |
| 35 | Maintenance and Servicing of canteen equipment's such as Rice boiler, vanali, chapatti buffer, water heater etc. including contacts etc., as per the scope of work and detailed tender specification. |
| 36 | Supply, transportation, installation, testing and commissioning of the following Sensors as directed by the Engineer-in-Charge. (Refer Sec VI, Clause No.16). Stand alone Ultrasonic motion detection sensor of range 4 m x 13m coverage flush mountable at height of 3mtrs to control switching lighting load of 10A with dual sensitivity to avoid nuisance switching. Along with presence detection, the sensor shall have built-in adjustable photocell to regulate the lighting levels as per availability of natural daylight in an area. Field adjustable features off-delay timer 10 sec, 5 min, 10 min & 15 min, photocell and power up. (Refer Sec VI, Clause No.16.3). |
| 37 | Supply and installation of 2.5 Sq.mm ZHFR wire as per technical specification |
| 38 | Supply and installation of 4 Sq.mm ZHFR wire as per technica specification |
| 39 | Supply and installation of Elcetronic timers as per technical specification |
| 40 | Supply and installation of SURFACE LIGHTS 6500K CCT,110lm/wt LED light fixtures as per tender specifications (Removal of existing fixture is in the scope of contractor) |
| 41 | Supply and installation of LINEAR RECESS 6500K CCT, 110 lm/wt LED light fixtures as per tender specifications (Removal of existing fixture is in the scope of contractor) |
| 42 | Supply and installation of class-C, 3mm thick, 33kV adhesive type insulation Mat IS-15652 as per tender specifications Please Enable Macros to View BoQ information |