|
| 1 | Excavation in trenches n.exc 1.5 M wide and n.exc 1.5 M in depth for pipe line, etc., in soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and as directed.Note: - Excavation where existing UG Cables/ water pipe lines are crossing manual excavation only will be allowed. |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm thick soft/ loose soil complete all as specified and as directed. |
| 3 | Removing excavated material (soils) from site to a distance n.exc 50 M away and depositing where directed at a level n.exc 1.5mtr above the starting point complete all as specified and as directed. |
| 4 | Boring holes under road pavement by bocky manually in any type of soil upto 200mm bore complete all as specified and as directed. |
| 5 | Supplying, laying, jointing, testing and commmisioning of DI Pipe as per IS: 8329/ 2000 ISI marked, class K-7 with inside cement mortar lining with spigot and socket ends and in and including suitable gasket joint (tyton joint) rubber joint complete laid in trenches complete all as specified and as directed at site for the following sizes:-Note: - Earth work and joints shall be measured and paid separetely |
| 6 | 100 mm bore |
| 7 | 150 mm bore |
| 8 | 200 mm bore |
| 9 | M & L for CI fittings/ specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the size upto 250mm dia confirming to IS: 1538-1993 complete all as specified and as directed. |
| 10 | M & L for DI fittings/ specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the size 250mm dia confirming to IS: 9523 complete all as specified and as directed. |
| 11 | Material and labour for Run lead joint including jointing material for CI/DI pipe of the 150 mm dia complete all as specified and as directed. |
| 12 | Supply, laying, jointing, welding & testing MS Pipe (Heavy duty class 'C') 6mm thick laid in trenches or on floors for connections to centrifugal pump sets for suction, pump to header and to connect out going water main CI/DI/MS pipe line complete all as specified and as directed.Note:- MS Flanges and Flange joints complete with jointing materials shall be measured and paid separately. |
| 13 | 80 mm bore |
| 14 | 100 mm bore |
| 15 | 150 mm bore |
| 16 | 200 mm bore |
| 17 | 250 mm bore |
| 18 | Supply and fixing, MS flanges of following sizes not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and as directed. |
| 19 | 50 mm bore |
| 20 | 80 mm bore |
| 21 | 100 mm bore |
| 22 | 150 mm bore |
| 23 | 200 mm bore |
| 24 | M & L for Flanged Joints with rubber or fibre board gasket including nuts, bolts and double washers of following sizes complete all as specified and as directed. |
| 25 | 50 mm bore |
| 26 | 80 mm bore |
| 27 | 100 mm bore |
| 28 | 150 mm bore |
| 29 | Supply, fixing, jointing & testing Cast Iron Sluice Valve of sizes as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top complete all as specified and as directed.Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 30 | 50 mm bore |
| 31 | 80 mm bore |
| 32 | 100 mm bore |
| 33 | 150 mm bore |
| 34 | Supply, fixing, jointing and testing of Cast iron Non Return valve without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete all as specified and as directed.Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 35 | 50 mm bore |
| 36 | 80 mm bore |
| 37 | 100 mm bore |
| 38 | 150 mm bore |
| 39 | 200 mm bore |
| 40 | Supply and fixing CI foot valve flanged ends, swing type opration with rubber sheet, as per IS:4038 complete all as specified and as directed.Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 41 | 50 mm bore |
| 42 | 80 mm bore |
| 43 | 100 mm bore |
| 44 | Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/ inclind/ vertical position, complete all as specified and as directed.Note:- Flange joints including jointing materials shall deemed to be included in the unit rate of this item. |
| 45 | 50 mm bore |
| 46 | 80 mm bore |
| 47 | 100 mm bore |
| 48 | 150 mm bore |
| 49 | Supplying & fixing gun metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS: 778 of following sizes complete all as specified and as directed. |
| 50 | 15 mm bore |
| 51 | 20 mm bore |
| 52 | 25 mm bore |
| 53 | 40 mm bore |
| 54 | 50 mm bore |
| 55 | Labour for cutting, welding of CI/ DI/ GI/ MS pipe in position for reducing to required length for insertion of new tees, branches, buterfly valve (wafer type) etc of upto 200mm bore complete all as specified and as directed. |
| 56 | M & L for fixing of water pressure gauge (0-5 Kg/cm square) 100mm dial size including boring, threading, welding in CI/ DI/ GI/ MS of any sizes and connected with suitable size of U type MS/ CP pipe with ON OFF cock complete all as specified and as directed. |
| 57 | M & L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of brick pillar to support the pipe line from site complete all as specified and as directed. |
| 58 | M & L for Brick work with sub class 'B' bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) as in brick pillar of required size and shape to support the pipe line complete all as specified and as directed. |
| 59 | M & L for rendering 10mm thick with cement mortar (1:6) on fair faces of brick work/ concrete surfaces, finished the surface even and fair complete all as specified and as directed. |
| 60 | M & L for GI tubing 'medium grade' with all accessories including bends, elbow, socket complete all as specified and directed |
| 61 | 40 mm bore |
| 62 | 50 mm bore |
| 63 | 80 mm bore |
| 64 | Supply, installation and testing flanged ends strainer/dirt box of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/ vertical position, complete all as specified and as directed.Note: - Flange joints including jointing materials shall deemed to be included in the unit rate of this item. |
| 65 | 50 mm bore |
| 66 | 80 mm bore |
| 67 | 100 mm bore |
| 68 | 150 mm bore |
| 69 | 200 mm bore |
| 70 | Supply and fixing Cast Iron Air Valves with two air outlets, conforming to IS 14845 of size 100mm dia bore and fixing up in Cast Iron/ Ductile Iron water supply mains of size 100mm dia in and including necessary fittings and taking down old any one complete all as specified and as directed. |
| 71 | Supply and fixing Cast Iron Air Valves with two air outlets, conforming to IS 14845 of size 150mm dia bore and fixing up in Cast Iron/Ductile Iron water supply mains of size 150mm dia in and including necessary fittings and taking down old any one complete all as specified and as directed. |
| 72 | Making bore hole under the road in any type of soil through trenchless technology by HDD (horizontal direction drilling method) including perparing and settin up the plant and eqpt, perparing new pipe/cable laying work like excavation shoring/ strutting etc drilling, stringing reaming pulling back the new work on the path alignment proper disposal of drilling fluid and the ground penetrating radar survey to protec existing utilities at the pipe/cable installation location restoration of site agter completion all inclusive as per and STT IS No 2.3 2.2 2.2 second edition 2008 code of practice of trenchless technology suitting indian condition for making horizontal bore size of 350mm dia suitable for HDPE pipe insertion under the road crossing hard standing including HDPE pipe of size 300mm nominal dia 28.30mm minimum wall thickness of grade PE 80 for protection of MS pipe/ cable to any depth complete all as specified and as directed. Please Enable Macros to View BoQ information |