| 1 | Schedule ‘A’ Section-IDesign & Construction of Modern Warehouse (Modern Ware House building, Staff Cabin with attached toilet, Toilet for Office Staff, etc) with allied services as a Pre-Engineered Building (PEB) as mentioned in Architectural drawings complete all as specified and shown on drawing and scope of work and other documents of the Tender and as mentioned in Annexures of scope of the work |
| 2 | Lump sum price worked out by the contractor for Schedule 'A' Section-II (SITE CLEARANCE) (Ref pre priced Schedule attached seperately) |
| 3 | Lump sum price worked out by the contractor for Schedule 'A' Section-III (INTERNAL WATER SUPPLY) (Ref pre priced Schedule attached seperately) |
| 4 | Lump sum price worked out by the contractor for Schedule 'A' Section-IV (INTERNAL ELECTRIC SUPPLY) (Ref pre priced Schedule attached seperately) |
| 5 | Lump sum price worked out by the contractor for Schedule 'A' Section-V (PLATFORM) (Ref pre priced Schedule attached seperately) |
| 6 | Lump sum price worked out by the contractor for Schedule 'A' Section-VI (ROAD/PATH CULVERT//HARD STANDING) (Ref pre priced Schedule attached seperately) |
| 7 | Lump sum price worked out by the contractor for Schedule 'A' Section-VII (SEWAGE DISPOSAL) (Ref pre priced Schedule attached seperately) |
| 8 | Lump sum price worked out by the contractor for Schedule 'A' Section-VIII (AREA DRAINAGE) (Ref pre priced Schedule attached seperately) |
| 9 | Lump sum price worked out by the contractor for Schedule 'A' Section-IX (RAIN WATER HARVESTING) (Ref pre priced Schedule attached seperately) |
| 10 | Lump sum price worked out by the contractor for Schedule 'A' Section-X (EXTERNAL WATER SUPPLY) (Ref pre priced Schedule attached seperately) |
| 11 | Lump sum price worked out by the contractor for Schedule 'A' Section-XI (EXTERNAL ELECTRIC SUPPLY) (Ref pre priced Schedule attached seperately) |
| 12 | Lump sum price worked out by the contractor for Schedule 'A' Section-XII (DEMOLITION/DISMANTLING) (Ref pre priced Schedule attached seperately) |
| 13 | Schedule ‘A’ Section- XIV (Miscellaneous Items) |
| 14 | (A) INTERNAL ELECTRIC SUPPLY |
| 15 | S&F LED Highway light fitting having following specifications :-(a) System Power : 200W(b) Housing : Pressuredie cast aluminium alloy with polyster powder coating (c) Cover : Tempered protective toughened glass thermal & shock resistant (d) Optics : LED module with SMD LED mounted on MCPCB(e) Rated Voltage : 240V(f) Minimum Safe operating Voltage range : 140V to 270V(g) Rated Frequecy : 50 Hz(h) Power Factor : ≥ 0.95(j) THD : ≤ 10(k) Operating Temp : - 10 deg C to + 50 deg C(l) Lumen Efficacy of LED : ≥ 150 Lm/W(m) System Luminous Efficacy : ≥ 130 Lm/W(n) CRI : ≥ 80 (o) CCT : 5000K to 5700K(p) Driver : Buitl- in Potted electronic, SMPS based constant current supply type having open circuit, short circuit, over voltage & surge voltage protecion upto 10KV with integral SPD.(q) IP rating : 65(r) IK rating : 07(s) Mounting : Suspended by means of heacy duty nickel plated forged eye bolt. |
| 16 | S&F in replacement sheet metal enclosure distribution board Vertical triple pole and neutral (VTPN), AC, 440 volts, 04 ways with minimum 200 Amps rated copper bus bar for each phase, 2 neutral bar, 2 earth bar and cable ties metal door with IP 30 & IK 08 protection confirming to IEC 61439-3, along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed suitable for 4-pole MCCB as incomer & MCB SP as outgoing having rating as per load requirement complete all as specified and directed. |
| 17 | Supply & fixing Turbo Roof Top Air Ventilator with following specifications :-(a) Turbine dia : 675mm(b) Neck/Throat Dia : 600mm(c) Bearing : 2 Nos, sealed type ( ZZ ) with permanent lubrication(d) Rivets : 3.2mm dia x 7mm of Aluminium alloy with lock washer(e) MOC (Vanes/Blades) : SS 304 (f) Blade Thickness : 0.4mm(g) No of Vanes : 42 Nos(h) Top Plate : SS 304(j) Bottom Plate :SS 304(k) Inner Arm : SS 304(l) Outer Arm : SS 304(m) Height : 320mm(n) Central Shaft : 16mm dia GI(o) Fixing Base : Polycarbonate sheet (approx size 5.5ft x 3.5ft) of Translucent or any colour to match with roof sheet profile. |
| 18 | (B) SEWAGE DISPOSAL |
| 19 | M &L for 150 mm nominal size (DWCPE) Double Wall Corrugated Polyethylene Pipe (SN8) including all fixing accessories or fittings like socket/spigot joint with elastomeric sealing ring, rubber ring, SILAID rubber lubricants required for laying of pipes, laid in trenches, complete all as specified and directed. |
| 20 | S & F of SFRC manhole cover with frame HD 100 mm thick complete all as specified and directed. |
| 21 | (C) AREA DRAINAGE |
| 22 | S&F SFRC perforated medium duty drain cover 100 mm thick complete all as specified and directed. |
| 23 | (D) RAIN WATER HARVESTING |
| 24 | S & F for SFRC manhole cover with frame and MS handle HD 100 mm thick complete all as specified and directed. |
| 25 | M&L HDPE pipe (SN8) 200mm nominal dia with pressure rating 10 Kg/Sqcm, laid in trenches and jointed complete all as specified and directed. |
| 26 | M&L for drilling 200 mm dia bore hole by DTH cum Rotary at any depth below the ground level in any kind of rock/soil up to 100m depth including disposal of surplus soil to a distance not exc. 50 mtr away complete all as specified and directed. |
| 27 | S&F self perforated UPVC pipe 200mm dia for pressure rating 10 Kg/Sqcm fixed complete to floors lowering and jointing self perforated in bore hole complete all as specified and directed. |
| 28 | S&F UPVC web cap 200mm dia complete all as specified and directed. |
| 29 | (E) PADESTAL FAN |
| 30 | M&L for point wiring with FRLSH PVC insulated and unsheathed cable 1.5 Sqmm (nominal area) ISI marked multi-stranded copper conductor single core including minimum 20mm dia medium grade PVC conduit Surfaced/Concealed in wall / false ceiling, Surfaced/Concealed metal flush boxes, including white cover plates with frame for fixing of modular switches/sockets etc with all accessories including 1.5 Sq mm PVC insulated and unsheathed stranded copper wire conductor cable to common earth and connecting to earth dolly including colour coding of cable shall be Phase - Red, Neutral- Black and Earth- Green complete all as specified and directed for One light/fan point/Exhaust fan controlled by one, one way switch 6 amps. |
| 31 | S&F modular Socket, 6A-3 pin combined 2 module, complete all as specified and directed. |
| 32 | S&F modular switch flush type, 5 Amps, single pole, one way 1 module complete all as specified and directed. |
| 33 | Supply and Fixing Heavy duty smooth oscillation type Pedestal fan 450 mm sweep 230 V, 50Hz , 1440 RPM with minimum air delivery 150 cubic-meter/min with Aerodynamically designed 3 Nos aliminium blades with minimul noise upto 65 dB, double ball bearing, electronic regulator and accessories complete all as specified and directed. |
| 34 | (F) UPS |
| 35 | Supply and fix High-efficiency True ONLINE UPS 15 KVA, 3ph: 3ph, ±415V , High Frequency dual Input, 5\\" touch Screen LCD Three Phase Input and Three Phase Output Online UPS System. IGBT BASE. High-efficiency True ON-LINE, IGBT based, Microprocessor Controlled Double Conversion Technology 3-phase UPS of capacity 15 KVA with One Hour backup with modular,scalable architecture. Input voltage range 300 to 450V and output 415 V ± 1% with pure sinusoidal less then equal to 4% THD, Multi-function LED status and display console follow IEC 62040 complete all as specified and directed. |
| 36 | (G) AIR CONDITIONING |
| 37 | Supply, installation, testing and commissioning of Higher Efficient models of SPLIT AC, THREE STAR RATING OF BEE (Bureau of Energy Efficiency), Digital Inverter twin rotary of capacity 2TR. confirming to latest Indian Standards and suitable for operation on 230Volts +10 %, single Phase, 50 Hz AC supply with rotary compressor, Refrigerant and capable to perform in built Heating and Cooling, dehumidifying, Air Circulating, Circulating, auto mode, auto swing, anti bacteria filtering, ventilation and with remote control with Cool/Fan/Dry/Auto mode, sleep mode & on/off timer with suitable thermostat. The outdoor unitshould be anti-rust powder coated. Indoor unit should have LED Display. The quoted cost shall include original fill and additional top up of refrigerant gas as per site condition and heavy ready made/fabricated MS Stand to house the out door unit complete all as specified and directed. |
| 38 | Supply and fix Voltage stabilizer for automatic operation, extra power booster single phase, naturally air cooled, indoor type & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of ± 2.5% suitable for 2 Ton AC (5 KVA) complete all as specified and directed. |
| 39 | (H) EXTERNAL WATER SUPPLY |
| 40 | M&L for making new water connections (tapping) by cutting / boring existing pipe line for 20mm dia size, fixed with clamp support complete all as specified and directed. |
| 41 | (I) EXTERNAL ELECTRIC SUPPLY |
| 42 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using manual technique complete all as specified and directed. |
| 43 | Supply & laying HDPE DWC pipe of OD/ID : 90/75 mm confirming to IS : 16205 (Part 24) : 2017 for cable protection in ground/along pole/wall complete all as specified and directed. |
| 44 | S&F PVC insulated sheathed 3 core 1.5 Sq mm multi stranded copper conductor cable for connecting junction box to street light fitting testing and commissioning all as directed. |
| 45 | Supply and fixing timelite distribution boards (street light DBs) 65 A 3 pole with 230 V Astronomical time switch complete all as directed |
| 46 | S&F loop-in/loop-out box of internal size 254 x 180 x 111 mm made out of hot pressed moulded SMC street light pole junction box with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 32 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box having IP-65 rating , duly fixed to to steel tubular pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed. |
| 47 | M&L for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective. |
| 48 | S & F LED Street light fitting 15 W having nominal voltage 240 V AC and operating voltage 140-270 V outdoor type with high pressure die cast aluminium alloy housing heat sink with high efficiency LED module with SMD LED package mounted on MCPCB with PC lens for uniform distribution of light, PC cover powered by integral electronic LED driver (SMPS based, constant current supply) having short circuit, over voltage, phase to phase voltage protection,IP:65/66, IK rating not less than 07, CCT 5700K, PF≥ 0.90 THD≤ 20, system lumen≥ 105 lm/W with 10 KV inbuilt surge protection device complete all as specified and directed. Note : Make of light fitting & driver shall be same and the manufacturer shall have in house NABL accredited lab. |
| 49 | Supply & fixing of Outdoor LT panel board facbricated from CRCA sheet 3.15 mm thick, powder coated shall be suitable for operation on AC 415 Volt, 3 Phase, 50 Hz, 4 wire system and shall have aluminium bus bar of capacity 100 Amps 4 Pole with colour insulating tape / sleeves mounted on suitable size \\"F\\" class, non hygroscopic, non combustible insulators, provision for fixing MCCBs / MCBs, necessary inter-connections with bus bar / strip with colour code insulation, including LED indicating lamps (R, Y, B), digital voltmeter with CT / PT & ammeter of suitable capacity with selector switches, provision of cable entry / exit provided in bottom, connections of all outgoing / incoming, existing / new copper wires of required size (minimum 2.5 sqmm), supported on angle iron frame with four legs 750mm long each (300 mm grouted in PCC) with MS Cable gland at entry/exit of cable aloghwith following accessories complete all as specified and directed:-Incoming :- (i) MCCB 4 pole 100 Amp, 16KA, Ics = Icu = 100%, thermal magnetic release adjustaple type, including spreader link - 01 No.(ii) 3 phase VAF + PF digital meter consisting of ammeter, voltmeter, frequency meter, PF, Cl 1 alongwith suitable CTs - 01 No Outgoing :- (i) MCCB 4 pole 63 Amp, 16KA, Ics = Icu = 100%, thermal magnetic release , including spreader link - 02 Nos.(for shed + 1 Spare)(ii) MCCB 4 pole 40 Amp, 16KA, Ics = Icu = 100%, thermal magnetic release, including spreader link - 01 Nos (For UPS)(iii) MCB 16 Amp 4 Pole - 01 No ( For timer switch)(iv) MCB 32 Amp 4 Pole -01 No (For Cabin DB) |
| 50 | Supply & fixing of MCCB 100 Amp 4 Pole 16 KA with sheet metal encloser DB on existing Panel complete all as specified and directed |
| 51 | (J) DISMANTLING / DEMOLITION |
| 52 | Taking Down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling rosses, pendants, regulators, sockets, light fittings, etc for taking credite complete all as specified and directed. |
| 53 | Taking Down carefully copper / aluminium submain point wiring of any size complete all as specified and directed. |
| 54 | Taking down carefully DB / TPN Enclosures / Change over switch, etc complete all as specified and directed. Please Enable Macros to View BoQ information |