Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 Volts with stranded aluminium conductor of size 10 Sqmm, 4 core laid in trenches or under road complete all as specified and as directed. Note: Excavation, sand and brick work shall be measured & paid separately |
| 2 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 Volts with stranded aluminium conductor of size 16 Sqmm, 4 core laid in trenches or under road complete all as specified and as directed. Note: Excavation, sand and brick work shall be measured & paid separately |
| 3 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 Volts with stranded aluminium conductor of size 35 Sqmm, 4 core laid in trenches or under road complete all as specified and as directed. Note: Excavation, sand and brick work shall be measured & paid separately |
| 4 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 Volts with stranded aluminium conductor of size 70 Sqmm, 4 core laid in trenches or under road complete all as specified and as directed. Note: Excavation, sand and brick work shall be measured & paid separately |
| 5 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 Volts with stranded aluminium conductor of size 120 Sqmm, 4 core laid in trenches or under road complete all as specified and as directed.Note: Excavation, sand and brick work shall be measured & paid separately |
| 6 | M&L for cutting of existing bitumen road/ hard standing / PCC for laying of cable/protection pipe complete all as specified and directed |
| 7 | Excavation in trenches not exc 1.5 mtr wide and not exec 1.5 mtr in depth for foundation etc or for laying pipe lines and cables and getting out as in lhard/dense soill complete all as specified and directed |
| 8 | Returning filling in including spreading leveling, watering and well ramming in layer not exc. 25 cm thick in soft/ loose soil, complete all as specified and directed. |
| 9 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed |
| 10 | S&F Galvanised iron steel tubes, ISI marked, light grade of size 50mm bore for cable protection along the poles under road under drains complete all as specified and directed |
| 11 | All as per Serial item No: 10 here-in-before but of size 80mm bore -ditto- |
| 12 | Taking down existing old ACSR from PCC/Steel poles complete all as specified and directed by Engr-in-Charge. |
| 13 | Taking down existing old cross arms of MS channel or angle sections etc all as specified and directed by Engineer-in-Charge. |
| 14 | Dismantling of old insulators pin/shakle complete and keeping aside for removal complete all as specified and directed |
| 15 | S&F danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20x15cm size complete all as specified and directed. |
| 16 | S&F Outdoor type LT Feeder piller box of size 600x450x300mm deep, 415 Volts, 3 phase, 4 wire 50 Hz having 04 Nos colour coded aluminium bus bar of capacity 160 Amps mounted on porcelain insulators with suitable number of holes for making connections of cables including 200 Amps porcelain kit kat fixded in box, made out of 3.15mm thick sheet steel CRCA and mounted on frame of suitable size made out of angle iron 45x45x6mm with 4 Nos legs embeded in PCC foundation 300mm below ground level and 300mm above ground level, duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, dust and vermin proof, front door with locking arrangement and two earth points by side of the box, cubical type with cable glands, sockets etc and with provision of cable entry from bottom, including painting steel frame and taking out old unserviceable feeder piller box, complete all as specified.Note: Drawing for LT feeder piller box shall be got approved by GE before fabrication. |
| 17 | S&F Duct pipe double wall ,corruugated HDPE 40 MM DIA outer dia conforming to IS;14930 (part-II) of approved colour with fitting for cable protection complete all as specified and as directed. |
| 18 | S&F Duct pipe double wall ,corruugated HDPE 75 MM DIA outer dia conforming to IS;14930 (part-II) of approved colour with fitting for cable protection complete all as specified and as directed. |
| 19 | S&F LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 300 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following :- |
| 20 | (i) MCCB 200 Amp Adjustable 36 KA, FP, single frame, (INCOMING) - 01 No (ii) MCB SPN 32 AMP single frame, (OUT GOING) - 4 Nos (iii) MCCB 63Amp Adjustable 25 KA, FP, single frame, (OUT GOING) - 04 Nos (iv) MCCB 40 Amp Adjustable 25 KA, FP, single frame, (OUT GOING) - 05 Nos(v) LED indicating Lamps ( R,Y,B) - one set(vi) Onload Change Over switch 200 A, FP-01 No(vii) Volt meter 0-500 V digital with selector switch-01 No(viii) Ampere meter 0-200 Amp with selector switch-01 No |
| 21 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 300Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following :- |
| 22 | (i) MCCB 200 Amp Adjustable 36 KA, FP, single frame, (INCOMING) - 01 No(ii) MCCB 100 Amp Adjustable 25KA, FP, single frame,(OUT GOING)-04 Nos(iii) MCCB TPN 63 Amp Adjustable thermal setting 25 KA, FP, single frame, (OUT GOING) - 04 Nos (iv) MCB SPN 32 Amp - 02 Nos(v) LED indicating Lamps ( R,Y,B) -01 Set(vi) Onload Change Over switch 200 A, FP-01 No(vii) Ampere meter 0-200 Amp with selector switch-01 No(viii) Volt meter 0-500 V digital with selector switch-01 No |
| 23 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 600 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following :- |
| 24 | (i) MCCB 400 Amp Adjustable 36 KA, FP, single frame, (INCOMING) - 01 No (II) MCCB 200 Amp Adjustable 25 KA, FP, single frame, (OUT GOING) - 03 Nos (iii) MCCB 250 AMP Adjustable 25 KA, FP, single frame, (OUT GOING) - 02 Nos (iv) MCCB160 AMP Adjustable 25 KA, FP, single frame, (OUT GOING) - 02 Nos (v) MCB SPN 32 Amp - 03 Nos (OUT GOING)(vi) LED indicating Lamps ( R,Y,B) -01 Set(vii) Onload Change Over switch 400 A, FP-01 No(viii) Volt meter 0-500 V digital with selector switch-01 No(ix) Ampere meter 0-400 Amp with selector switch-01 No |
| 25 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 300Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following:- |
| 26 | (i) MCCB 200Amp Adjustable 36KA, FP, single frame, (INCOMING) - 1 No(ii) MCCB 100 Amp Adjustable 25KA, FP, single frame, (OUTGOING) - 2 Nos (iii) LED indicating Lamps ( R,Y,B) - one set(iv) ON load Change Over switch 200A, 4P-01 No(v) Volt meter 0-500 V digital with selector switch-01 No(vi) Ampere meter 0-200 amp with selector switch-01 No |
| 27 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 150 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following:- |
| 28 | (i) MCCB 100 Amp Adjustable 25KA, FP, single frame, (INCOMING) - 1 No (ii) TPN 63 Amp 25 KA, (OUT GOING) - 02 Nos (iii) MCB SPN 32 Amp - 05 Nos (iv) LED indicating Lamps ( R,Y,B) -one set (v) Onload Change Over switch 100 A, 4P-01 No(vi) Volt meter 0-500 V digital with selector switch-01 No.(vii) Ampere meter 0-100 amp with selector switch-01 No. |
| 29 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 150 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following :- |
| 30 | (i) MCCB 100 Amp Adjustable 25KA, FP, single frame, (INCOMING) - 01 No. (ii) MCCB TPN 40 Amp 25KA, (OUT GOING) - 05 Nos (OUT GOING)(iii) LED indicating Lamps ( R,Y,B) - one set(iv) ON load Change Over switch100A, 4P-01 No(v) Volt meter 0-500 V digital with selector switch-01 No.(vi) Ampere meter 0-100amp with selector switch-01 No. |
| 31 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 150Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following:- |
| 32 | (i) MCCB 100 Amp Adjustable 25KA, FP, single frame, (INCOMING) - 01 No. (ii) MCCB TPN 40 Amp 25KA, (OUT GOING) - 06 Nos (iii) LED indicating Lamps ( R,Y,B) - one set(iv) On load Change Over switch 100A, 4P-01 No(v) Volt meter 0-500 V digital with selector switch-01 No.(vi) Ampere meter 0-100 amp with selector switch-01 No. |
| 33 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 250 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following:- |
| 34 | (i) MCCB 160 Amp Adjustable 25KA, FP, single frame, (INCOMING) - 01 No. (ii) MCCB TPN 32 Amp 25KA, (OUT GOING) - 03 Nos (iii) LED indicating lamps ( R,Y,B) -one set(iv) On load Change Over switch 160A, 4P-01 No.(v) Volt meter 0-500 V digital with selector switch-01 No.(vi) Ampere meter 0-63 Amp with selector switch-01 No. |
| 35 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 250 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following:- |
| 36 | (i) MCCB 40 Amp Adjustable 25KA, FP, single frame, (INCOMING) - 01 No. (ii) MCCB TPN 32 Amp 25KA, (OUT GOING) - 04 Nos(iii) LED indicating Lamps ( R,Y,B) - one set (iv) Off load Change Over switch 40 A, 4P-01 No(v) Volt meter 0-500 V digital with selector switch-01 No.(vi) Ampere meter 0-40 Amp with selector switch-01 No. |
| 37 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 300Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following:- |
| 38 | (i) MCCB 400Amp Adjustable 36KA, FP, single frame, (INCOMING) - 01 No. (ii) MCCB 160 Amp Adjustable 25KA, FP, single frame, (OUTGOING) - 2 Nos (iii) MCCB 100 Amp Adjustable 25 KA, FP, single frame, (OUT GOING) - 01 No. (iv) MCB SPN 32 Amp - 02 Nos (v) LED indicating Lamps ( R,Y,B) - one set(vi) ON load Change Over switch 400, 4P-01 No(vii) Volt meter 0-500 V digital with selector switch-01 No.(viii) Ampere meter 0-400 Amp with selector switch-01 No. |
| 39 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 150Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following:- |
| 40 | (i) MCCB 100 Amp Adjustable 25KA, FP, single frame, (INCOMING) -01 No. (ii) MCCB 63Amp Adjustable 25 KA, FP, single frame, (OUT GOING) - 05 Nos (iii) MCB SPN 32 Amp - 02 Nos(iv) LED indicating Lamps ( R,Y,B) - one set(v) Volt meter 0-500 V digital with selector switch-01 No.(vi) Ampere meter 0-200 Amp with selector switch-01 No. |
| 41 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 240Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following:- |
| 42 | (i) MCCB 160 Amp Adjustable 36KA, FP, single frame, (INCOMING) - 01 No. (ii) MCCB 100 Amp Adjustable 25KA, FP, single frame, (OUTGOING) - 3 Nos (iii) MCB SPN 32 Amp - 2 Nos (iv) LED indicating Lamps ( R,Y,B) - one set(v) ON load Change Over switch 160 A, 4P-01 No.(vi) Volt meter 0-500 V digital with selector switch-01 No.(vii) Ampere meter 0-200 amp with selector switch-01 No. |
| 43 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 300Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following:- |
| 44 | (i) MCCB 250 Amp Adjustable 36KA, FP, single frame, (INCOMING) - 01 No. (ii) MCCB 100 Amp Adjustable 25KA, FP, single frame, (OUTGOING) - 6 Nos (iii) MCCB 63Amp Adjustable 25 KA, FP, single frame, (OUT GOING) - 04 Nos (iv) MCB SPN 32 Amp - 04 Nos (v) LED indicating Lamps ( R,Y,B) - one set(vi) ON load Change Over switch 250A, 4P-01 No.(vii) Volt meter 0-500 V digital with selector switch-01 No.(viii) Ampere meter 0-300 amp with selector switch-01 No. |
| 45 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 188Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following : |
| 46 | (i) MCCB 125 Amp Adjustable 36KA, FP, single frame, (INCOMING) - 01 No. (ii) MCCB 100 Amp Adjustable 25KA, FP, single frame, (OUTGOING) - 06 Nos (iii) MCCB 63Amp Adjustable 25 KA, FP, single frame, (OUT GOING) - 04 Nos (iv) MCB SPN 32 Amp - 04 Nos (v) LED indicating Lamps ( R,Y,B) - one set(vi) ON load Change Over switch 125A, 4P-01 No(vii) Volt meter 0-500 V digital with selector switch-01 No.(viii) Ampere meter 0-200 amp with selector switch-01 No.(ix) Street light three phase timer-3p module, 24 hours program, programmable every 15min, backup of 100 hrs,current capacity16 Amp -1 No. |
| 47 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 150 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/OUT GOING with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following :- |
| 48 | (i) MCCB 100 Amp Adjustable 25KA, FP, single frame, (OUTGOING) - 01 No. (ii) MCCB 63Amp Adjustable 25 KA, FP, single frame, (OUT GOING) - 04 Nos (iii) MCCB 16 AMP Adjustable type 16 ka FP, Singal frame ( OUT GOING )-2 Nos(iv) Street light three phase timer-3p module,24 hours program, programmable every 15min, backup of 100 hrs,current capacity16 Amp -1 No(v) LED indicating Lamps ( R,Y,B) - one set(vi) ON load Change Over switch 100A, 4P-01 No(vii) Volt meter 0-500 V digital with selector switch-01 No.(viii) Ampere meter 0- 150 amp with selector switch-01 No.(ix) Street light three phase timer-3p module,24 hours program, programmable every 15min, backup of 100 hrs, current capacity16 Amp -1 No |
| 49 | M&L for cable route indicator with a welded/riveted disc of inch dia and engraved with cable with cable route markar made out of angle iron 40X40X40mm thick dug in ground with in and incl PCC 1:3:6 type C1 using 20mm graded aggtegate at approx distance 30 mtr including necessary earth work complete all as specied and directed |
| 50 | S&F in replacement loop in loop out box with transparent lid IP 65 weather proof of suitable size fixed to pole / wall with suitable FI clam 20X3MM nuts,bolts and washers incl provision of 01 no miniature circuit breker (MMCBs) SPN 'C' SERIES,240 VoltS 10KA 06 Amps and incl suitable for 01 No. 50/16 sqmm x 3.5/4 core XLPE outgoing cable complete all as specified and directed |
| 51 | M&L for connection the street light point from loop in loop out box by using a two runs of singal core 1.5 sqmm.PVC insulated sheathed FR Copper conductor cable including PVC conduit/ floxole pipe of suitable dia along with one run of 1.5 sqmm FR copper cable for earth continuity conductor as earth lead for street light complete all as specified and directed |
| 52 | M&L for commissioning, installation and testing of maintenance free UL approved chemical earthing with copper earth plate electrode 90cm x 60cm x 5 mm thick buried directly in ground vertically at a depth not less than 4.2 metre below normal ground level with top edge of earth plate at a depth not less than 3 meter below normal ground level, earth plate covered with LHOM Earth enhancing chemical compound (Bentonite powder) all around the plate upto 30 cm and electrode connections by using copper strip of 32 x6 mm as earthing lead (upto the test point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 80mm dia GI pipe filled with earth enhancing chemical compound connected to main switch board or main control board including RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR Part 1 complete all as specified and as directed. Make JMV LPS Ltd/ OBO/ENNOV Infra Solutions Pvt. Ltd/ Erico /Powerbolt. |
| 53 | M&L for earthing to Panel / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |