| 1 | Tubewell |
| 2 | Drilling of Trial bore of 150 inch dia including cost of consumables ,Labor & other required material at site. Note: Drilling of trail bore is mandatory and if 2 nos water sample from bore found potable then the further drilling of main bore will be started. |
| 3 | Drilling of 550mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. complete in all respect. |
| 4 | Drilling of 550mm dia bore with Reverse Rotatry Rig Upto 150 m depth BGL. |
| 5 | Drilling of 550mm dia bore with Reverse Rotatry Rig Beyond 150 m depth BGL up to 300 Mtr |
| 6 | Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. |
| 7 | 250mmnominal diameter (weight 52.3 kg per metre) 8.0 mm thickness |
| 8 | Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore. |
| 9 | 250mm Steel Strainer (slot size 0.75mm) 7.30 mm thickness |
| 10 | Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect. |
| 11 | 250mm internal diameter |
| 12 | Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect. |
| 13 | 250mm internal diameter (weight 52.3 kg per metre) 8.00 mm thickness |
| 14 | Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect.250mm internal diameter |
| 15 | Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 16 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 17 | Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. |
| 18 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. |
| 19 | 250mm internal diameter |
| 20 | Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 21 | Capacity of Air compressor 300 cfm at 250 PSI |
| 22 | Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 23 | Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) |
| 24 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide, Uranium etc.) |
| 25 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe) |
| 26 | Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect |
| 27 | Provision for Sanitary Clay Seal (As per BIS Code IS 2800-2019) including sterlization of tubewell. |
| 28 | Constructing one No. of 250 KL (250000 ltrs) Capacity with sill level not less than 23.50m height upto FSL 27.50 mtrs from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing D.I K-9 D/F expansion joints conforming to (IS-1536-1989) or latest bell mouth and D/F puddle collars. Duck foot bends, Conforming to ISI - 13382 and DI K-9 D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow DI K-9 double flanged pressure pipes horizontally cast in sand moulds as per IS 7181/1986 and latest duly ISI marked from bottom dome to duck foot bend and further up to 7.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminum leader inside the OHSR complete in all respect as per specifications. The specifications & drawing are based on safe bearing capacity of soil is greater than or equal to 8.75 ton per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per sqm., the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Premium including providing and fixing automatic Electronic Water Level control Device and construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling including overflow haudi complete in all respects. (including carriage of materials) Note 1) Providing and applying integral crystalline slurry of hydrophilic in nature for water proofing management etc.(For vertical and horizontal surface. 2) Providing and applying of swellable type water staop tape etc.Note:- The design of RCC OHSR will be provided by contractor's own cost after got designed by GNE Ludhiana or any other reputed engineering Institute. |
| 29 | Rising Main |
| 30 | Providing, Laying, fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications (Excavation mechanically) 160mm o/d uPVC Pipe (10 kg./cm2) |
| 31 | 160mm o/d uPVC Pipe (10 kg./cm2) |
| 32 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).Class PN-1 as per ISI |
| 33 | 100mm i/d Sluice Valves flanged |
| 34 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. |
| 35 | Size 0.9 m. x 0.9 m. |
| 36 | Distribution System |
| 37 | Providing, Stringing out PVC pipes 6kg/cm2 ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing complete as per specifications for less than 3 mtr street width (with mannual earth work) |
| 38 | PVC pipe 63mm o/d PVC 6 kg/cm2 |
| 39 | PVC pipe 75mm o/d PVC 6 kg/cm2 |
| 40 | PVC pipe 90mm o/d PVC 6 kg/cm2 |
| 41 | PVC pipe 110mm o/d PVC 6 kg/cm2 |
| 42 | Providing, Stringing out PVC pipes 6kg/cm2 ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing complete as per specifications for street (with mechanical earth work) |
| 43 | PVC pipe 63 mm o/d (6kgf/ cm2) Pressure |
| 44 | PVC pipe 75 mm o/d (6kgf/ cm2) Pressure |
| 45 | PVC pipe 90 mm o/d (6kgf/ cm2) Pressure |
| 46 | PVC pipe 110 mm o/d (6kgf/ cm2) Pressure |
| 47 | PVC pipe 160 mm o/d (6kgf/ cm2) Pressure |
| 48 | PVC pipe 200mm o/d (6kgf/ cm2) Pressure |
| 49 | DISMANTLINGDismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position |
| 50 | 63mm i/d PVC Pipe |
| 51 | 75mm i/d PVC Pipe |
| 52 | 90mm i/d PVC Pipe |
| 53 | 110mm i/d PVC Pipe |
| 54 | 160mm i/d PVC Pipe |
| 55 | DISMANTLINGDismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position |
| 56 | 63mm o/d PVC Pipe |
| 57 | 75mm o/d PVC Pipe |
| 58 | 90mm o/d PVC Pipe |
| 59 | 110mm o/d PVC Pipe |
| 60 | 200mm o/d PVC Pipe |
| 61 | Dismantling and restoration of Cement concrete Streets complete in all respects. |
| 62 | Dismantling and Relaying of metalled road the restoration of the metalled road to its original condition. |
| 63 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).Class PN-1 as per ISI |
| 64 | 80mm i/d Sluice Valves flanged |
| 65 | 100mm i/d Sluice Valves flanged |
| 66 | 150mm i/d Sluice Valves flanged |
| 67 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. |
| 68 | Size 0.6 m. x 0.6 m. |
| 69 | Size 0.9 m. x 0.9 m. |
| 70 | Hand boring Horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method.Including excavation , stringing and jointing of pipe upto 160mm complete |
| 71 | Connection with existing PVC pipe including cost of PVC tee and PVC saddle piece and earth work in excavation & back filling complete in all respect |
| 72 | HOUSE SERVICE CONNECTIONS |
| 73 | Providing proposed water connection to house hold upto wall with providing laying jointing testing GI pipes lines 15mm i/d B Class as per above GL Providing and fixing MDPE pipe 15mm i/d with specials (Below GL) including cost of specials such as tees bends sockets elbow etc cutting threading and testing in trenches in the ground and ISI 15mm i/d GM ferrule as per IS 2692 and 3\\" i/d clamp with CI bib cock 15mm i/d as per IS 210 with stainless steel spindle of approved make complete in all respects. |
| 74 | Water Meter |
| 75 | Providing, fixing & jointing multijet water meter of approved make as per IS:779/94 in G.I.Pipe line including cutting and threading pipe including cost of water meter but excluding cost of specials, Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including filter and all carriages, 15mm i/d Brass Ball valves of G.I. Nipple 15mm x 150mm, Supply of G.I. Nipple 15mm x 100mm, Supply of G.I. elbow 15mm i/dia ISI Marked Providing, fixing and jointing Union Couplings in G.I. Pipe Lines Providing & Fixing G.I. Hooks complete in all respect. Note :- The contractor will ensure that the water Meters will be procured only from those manufactures who has obtained manufacturer's license from Legal Metrology Dept., Punjab. Further the contractor has to submit a certificate regarding inspection of water meter makes as per provision of legal metrology act, 2009 prior to their installation and ensure compliance to the provision of legal Metrology Act. |
| 76 | PUMP CHAMBER WITH WC |
| 77 | Construction of Pump Chamber size 3.05m×3.70m, Without gravel pit but including electric wiring as per DWSS standard design & analysis, complete in all respects. Including provision for Sanitary Latrine in pump Chamber for Foundation and plinth of WC rooms including flooring, PVC pipes, Junction Box, 1 Nos. Leach Pits, Super structure WC Room etc. Complete in all respect. |
| 78 | D.I Fitting |
| 79 | Providing and installing 150mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard drawing of DWSS complete in all respects. |
| 80 | Pumping Machinery |
| 81 | Providing & installing, testing & commissioning of 1 no electrically driven Submersible Pump set capable of delivering 1007 LPM against a head of 119 mtr. along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter,Main Switch,VM,AMpere Meter,ELCB,Shunt capacitor.Single phase,preventer,Indicating lamps,Kit-Kat etc. including GI column Pipe of IS 1239-2004 medium class size 100mm and Length 81mtr.(in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 180 Mtr. Length and10.00mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects. |
| 82 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.100mm i/d |
| 83 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS: 694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge. Cable (Size/Cost) 10.00mm2 |
| 84 | Panel Board |
| 85 | Development of Water Works |
| 86 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per Standard Drawing DWSS. |
| 87 | Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4\\" x 4\\", size top 3\\" x 4\\",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. |
| 88 | Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing DWSS. |
| 89 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing DWSS. |
| 90 | Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing DWSS complete in all respects |
| 91 | Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing DWSS. |
| 92 | Providing & fixing MS Sign Board as per standard size of DWSS as per Drawing complete in all respect. |
| 93 | Solar Panel |
| 94 | Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects. |
| 95 | Carriage of Material |
| 96 | Carriage of material such as Sand upto end 0-90 KM |
| 97 | Carriage of material such as Bajri upto end 0-90 KM |
| 98 | Difference of rate of Bricks |
| 99 | Environmental Management |
| 100 | HORTICULTURESite clearance |
| 101 | Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil. |
| 102 | Supplying and planting permanent trees in prepared pits and watering |
| 103 | Planting seasonal flower in beds |
| 104 | Planting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row. |
| 105 | Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row. |
| 106 | Provision for one way stand post with Khura complete in all respects |
| 107 | Chlorination & Disinfection |
| 108 | Prov. Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator ,suitable for delivering 0.5 to 6 Litres of Bleaching Powder Solution/Sodium Hypo solution per hour under maximum delivery pressure up to 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS. standard specifications. |
| 109 | Bulk Meter |
| 110 | Providing & Installing Bulk Meter inside Pump Chamber including Rubber Jain, Nut, Bolts, Cutting and threading, piece for fixing bulk meter including carriage complete in all respect. (Make ISI Nelson) Size 150mm i/d Please Enable Macros to View BoQ information |