| 1 | Panel Work |
| 2 | Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays,indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame). The panel shall be fabricated by a CPRI-approved fabricator. Based on the request of the Assistant Engineer (Electrical), the purchase order shall be confirmed by the fabricator. Inspection of the panel during fabrication may be carried out at the discretion of the Assistant Engineer (Electrical), if deemed necessary, to ensure quality compliance. All sheets used in the panel shall be fabricated using CRCA material of uniform thickness. Irrespective of whether the inspection is conducted, the responsibility for the quality and performance of the panel shall rest solely with the contractor to whom the work is awarded by CUSAT. All Factory Acceptance Test (FAT) certificates, in accordance with the latest IS/IEC or other applicable standards, shall be submitted along with the panel. |
| 3 | Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc |
| 4 | Supply and providing heavy duty 'A' section neoprene gasket in the panel board U' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 5 | Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) |
| 6 | Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 7 | Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. As required. |
| 8 | Supply and providing copper earth bus in the panel board |
| 9 | 800 A, 4 pole, electrical draw out type, microprocessor based ACB with overload , instantaneous SC , delayed SC and ground fault protection 50kA |
| 10 | Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 -100% having adjustable OL & SC |
| 11 | Supply, conveyance and fixing the following types & current rated control gears &switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.320A/400A, 50/55 kA (Ics=100%Icu), 4 pole,current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 12 | MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A |
| 13 | MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A |
| 14 | Supply, conveyance and fixing the following types & current rated control gears &switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16A -100A, 35/36 kA (Ics=100%Icu), 4 pole,current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 15 | Supply & Fixing of Earth Fault Protection relay (MC12A) in an existing panel Board (Make: L&T/L&K Schneider, Siemens) including connections as required |
| 16 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 17 | Supply and Fixing of 1 No. 800/5 A, 15 VA, accuracy class 5P/ 10 P 10, ProtectionCT (Tape wound) |
| 18 | Supply and fixing of 800/5 A, 15 VA, accuracy class 1, Tape wound CT |
| 19 | Supply and fixing of 600/5 A, 15 VA, accuracy class 1, Tape wound CT |
| 20 | Supply and installation of Voltmeter selector switch 6 A 3 Pole |
| 21 | Supply and installation of Ammeter selector switch 6A 3 Pole |
| 22 | Supply and installation of Three Phase Voltmeter accuracy class 1 |
| 23 | Supply and installation of Three Phase Ammeter accuracy class 1 |
| 24 | Supply and fixing 1 set ( 3 Nos ) R,Y,B LED indication lamp AC/DC, 22.5 mm cutout dia. On existing panel board. Including connections , terminations etc completed. |
| 25 | Cabling |
| 26 | Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm). |
| 27 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 120 sq mm |
| 28 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 150 sq mm |
| 29 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 240 sq mm |
| 30 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 300 sq mm |
| 31 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 400 sq mm |
| 32 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 33 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 34 | Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) |
| 35 | Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm) |
| 36 | Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) |
| 37 | Supplying and making straight through joint with heat shrinkable kit includingferrules and other jointing materials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 120sq. Mm |
| 38 | Supplying and making straight through joint with heat shrinkable kit includingferrules and other jointing materials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 150sq. Mm |
| 39 | Supplying and making straight through joint with heat shrinkable kit includingferrules and other jointing materials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 240sq. Mm |
| 40 | Supplying and making straight through joint with heat shrinkable kit includingferrules and other jointing materials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 300sq. Mm |
| 41 | Supplying and making straight through joint with heat shrinkable kit includingferrules and other jointing materials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 400sq. Mm |
| 42 | Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 43 | Earthing |
| 44 | Supply and clamping the following size of strips on surface of wall/ parapet/ existingcable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy dutyGI spacer saddles spacing of clamps not exceeding 1 m, making good the damages,colour washing etc. as required ( for horizontal run)25 x 6 mm copper strip |
| 45 | Trench work |
| 46 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 47 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 48 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 49 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 50 | Centering and shuttering including strutting, etc. and removal of form for:Walls (anythickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 51 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 52 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 53 | Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat, preparationof surface, etc. complete.On steel work |
| 54 | Miscellaneous Items |
| 55 | Fee amount for getting the scheme and energization approval from Electricalinspectorate (will be reimbursed after obtaining approval from KSEI on producing ofreceipt from KSEI.) |
| 56 | Preparation of necessary forms, documents, drawing etc of complete installationnecessary for getting approval and Energization certificate from Kerala ElectricalInspectorate. |
| 57 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 58 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 59 | Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 40 amps |
| 60 | Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 61 | Supply and installation of DP MCB enclosure with accessories for fixing theenclosure on the wall, including DIN rail, screws, washers, and other necessarymounting accessories for proper installation of the DP MCB inside the enclosure. |
| 62 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm |
| 63 | Supply and fixing of following sizes of light gauge PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required 20 mm |
| 64 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 65 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet |
| 66 | Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module |
| 67 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessoriesin surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface |
| 68 | Dismantling of the old and obsolete MSB panel from Substation No.1 and shifting itto the auction yard as per the directions of the Assistant Engineer. The scope of workalso includes disconnection of all connected cables and earthing from the MSB panel |
| 69 | Supply and fixing minimum 3mm MS chequered plate |
| 70 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm |
| 71 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X1.5 sq.mm |
| 72 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 73 | Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired. |
| 74 | Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module(75mmX75mm) |
| 75 | Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 76 | Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 77 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6amps switch |
| 78 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required. 3pin 5/6 amp socket outlet |
| 79 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required. |
| 80 | Supplying and fixing brass batten/ angle holder including connection etc. as required |
| 81 | Conveyance, installation , testing and commissioning of exhaust fans of size up to450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., asrequired including giving connections with the supplied wire along with the exhaustfan. |
| 82 | Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mmFRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply |
| 83 | Charges for cutting holes suitable for accommodating exhaust fans up to 305mmsweep including plastering colour washing etc. as required. |
| 84 | Supply & installation of light fittings on TW round blockSupply, conveyance installation testing and commissioning the light fittings offollowing types made of CRCA with 0.5mm thickness complete with all accessoriesand lamps etc. directly on wall or ceiling with PVC round block neatly painted to suitthe fitting and giving connection with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS and giving connections asrequired.1200 mm 1X20W LED Lamp with box type fixture |
| 85 | Supply & installation of light fittings on TW round blockSupply, conveyance installation testing and commissioning the light fittings offollowing types made of CRCA with 0.5mm thickness complete with all accessoriesand lamps etc. directly on wall or ceiling with PVC round block neatly painted to suitthe fitting and giving connection with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 2X20W LED Lamp with box type fixture |
| 86 | Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required 8 way (8+24) - double cover TPN verticalDB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/TP MCB as outgoing (IP 42/43) |
| 87 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 88 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps |
| 89 | Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 63 amps |
| 90 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole and neutral |
| 91 | Supply and installation of FP MCB enclosure with accessories for fixing theenclosure on the wall, including DIN rail, screws, washers, and other necessarymounting accessories for proper installation of the FP MCB/ISOLATOR inside theenclosure. |
| 92 | Dismantling of damaged switch boards, conduits etc in the substation-1 and shifting the same to electrical section store as per the direction of engineer incharge |
| 93 | Dismantling of existing APFC Panel and refixing the same in appropriate location asper statutary clearence between panels |
| 94 | Supply of 305 mm sweep, 1400 rpm, 230 V heavy duty exhaust fan. |
| 95 | Supply and installation of 9W LED Bulb (B22) on existing bulb holder as required |
| 96 | Supply of Metal blade Pedestal Fan 450mm sweep (Crompton or Equivalent make)with minimum 3 speed control Please Enable Macros to View BoQ information |