| 1 | Supply , Installation, Testing and Commissioning of Floor mounted, Air cooled, Top discharge type Packaged AC unit (both indoor and outdoor unit), having capacity 17.0TR or above with digital thermostat control. copper coil condenser with anti corrosive fins. The refrigerant used shall be eco friendly and approved type. The input power shall be suitable for 3Ph, 380-415V, 50Hz, AC. This also includes all the necessary works required for the successfull installation, and commissioning of the unit which are not included in item Nos 2 to 14 without any additional cost. Warranty:36 months (Make: Daikin, Mitsubishi Electric, Blue Star, Carrier) |
| 2 | Supply and providing MS Angle frame works of suitable size for mounting AC outdoor/indoor unit fabricated ,suitably treated, painted/powder coated in C-channel or Angled Iron) as required |
| 3 | Supply and providing closed cell nitrile rubber having minimum 19mm thick insulated copper pipe( Hard) for outdoor to indoor interconnection as required. PVC Self adhesive mansoon tape should be wrapped,consider liquid and gas line as a pair 5/8 & 7/8. |
| 4 | 25/32 mm Dia UPVC drain pipe with insulation( done for inside pipes ) of – schedule 40 pipe, white in colour, joint properly glued with UPVC adhesive for water outlet from indoor unit. Drain line to be connected to the nearest drain pit as per site condition. |
| 5 | Supply and providing required size electrical control cable for indoor to outdoor interconnection as recommended by the manufacturer, run through suitable size PVC conduit, minimum 3Cx1.5 Sqmm Copper. |
| 6 | Supply and providing required size electrical power cable for indoor unit connection as recommended by the manufacturer , run through suitable size PVC conduit, minimum 4x10sqmm, Copper. |
| 7 | Supply,erection of fabricated minimum 0.63mm GSS ducting as per drawing complete with all fttings. |
| 8 | Supply,erection of fabricated minimum 0.80mm GSS ducting as per drawing complete with all fittings. |
| 9 | Supply & installation of acoustic insulation of minimum13 mm thick closed cell elastomeric nitrile rubber insulation. |
| 10 | Supply and fixing Volume Control Dampers of required size to connect at machine mouth |
| 11 | Supply and fixing of canvas connection |
| 12 | Core packing charges of Existing Holes of Refrigerant pipe route and making it leak proof |
| 13 | Additional refrigerant Charging if Required |
| 14 | Dismantling of , Existing Packaged units 16.5 TR and 3 Condensing Units for each Indoors, Existing Mouth piece connection of ducts,Canvas connection, associated Copper pipies , & drain pipes ,its supports etc from existing position to shifting to the designated position. |
| 15 | Buyback of 16.5 TR capacity packaged AC units with associated copper pipes, Indoor to outdoor electrical cables,Make Voltas Please Enable Macros to View BoQ information |