| 1 | Installation of 11/0.4kv,100KVA DSS(Plinth mounted) - 160X160 mm WPB GI Pole 11 Mtr long |
| 2 | Earthing of Support(Coil Type) |
| 3 | Danger Board |
| 4 | Back clamp for Danger Board(25x3)mm flat 0.59kg/mtr flat of 0.510 mtr length,2 nos=(2x0.59x0.510) |
| 5 | GI Barbed Wire(Anticlimbing device@3kg/support) |
| 6 | Back clamp for Anticlimbing device(25x3)mm flat 0.59kg/mtr flat of 0.510 mtr length,8 nos=(8x0.59x0.510) |
| 7 | Pressure channel 100X50X6mm, 2.8mtr 2 No(9.2Kg/Mtr.) with Galvanisation charges |
| 8 | Transformer mounting channel 100X50X6mm, 2.8mtr long 2 Nos.(9.2Kg/Mtr.) with Galvanisation charges |
| 9 | AB Switch & HG fuse mounting channel 75X40X6 mm,2.8mtr.Long 4 Nos.(6.8Kg/mtr) with Galvanisation charges |
| 10 | Cantilever channel for supporting HG fuse 75X40X6mm MS Angle 1 mtr. Long 2 Nos. (6.8Kg/mtr) with Galvanisation charges |
| 11 | Angle for Cantilever arrangement for supporting HG fuse 50X50X6mm MS Angle 2 mtr. Long 2 Nos. (4.5Kg/mtr)with Galvanisation charges |
| 12 | Transformer belting 50X50X6mm MS Angle 2.8 mtr. Long 2 Nos. (4.5 Kg/mtr) with side angle total 7mtr with Galvanisation charges |
| 13 | Angle for mounting of LT distribution box 35X35X5mm 1mtr long each 2nos, (3.5Kg/Mtr) with Galvanisation charges |
| 14 | AB Switch 11kv,3 pole,400A,50Hz |
| 15 | HG Fuse11kv,3 pole,400A |
| 16 | 11kv Lighting arrester 12kv,10KA |
| 17 | H.T Stay set(Complete) |
| 18 | H.T Stay set Insulator Type-C |
| 19 | H.T Stay Clamp |
| 20 | 7/10 SWG Stay Wire(Grade-2) |
| 21 | GI pipe earthing 40 mm dia medium gauge 3 mtr long. |
| 22 | G.I. Flat (25x4) mm for earthing |
| 23 | G.I. Flat (25x54) mm for Neutral earthing |
| 24 | 100 KVA ,11/0.4 KV(AL) Transformer BIS Energy level -II |
| 25 | LT Distribution Box with MCCB, Alluminium busbar of two bay with Kit Kat fuse for 100 Kva S/s |
| 26 | LT 3.5 core,120 MM2 LT pvc Cable (Unarmoured) |
| 27 | 55 mm sq AAA Conductor for jumpering |
| 28 | PG Clamp for 55mm2 AAA Conductor |
| 29 | GI Nut Bolt & Washer |
| 30 | Sundries for survey ,PVC tape Ampire tape,Danger Boardsmall size nut-bolt preparation of drawing etc |
| 31 | Erection of 11kv,3p,3w oh Line over 2 nos 11 mtr long WPB Pole - 160X160 mm WPB GI Pole 11 Mtr long |
| 32 | Earthing of Support(Coil Type) |
| 33 | Danger Board |
| 34 | Back clamp for Danger Board(25x3)mm flat 0.59kg/mtr flat of 0.510 mtr length,2 nos=(2x0.59x0.510) |
| 35 | GI Barbed Wire(Anticlimbing device@3kg/support) |
| 36 | Back clamp for Anticlimbing device(25x3)mm flat 0.59kg/mtr flat of 0.510 mtr length,8 nos=(8x0.59x0.510) |
| 37 | 100X50X6mm,MS Channel for straight cross arm 1.2 mtr 6 No(9.2Kg/Mtr.) with Galvanisation charges |
| 38 | Fish plate 50X8 mm, 0.28mtr long (0.97Kg/Mtr.) with Galvanisation charges |
| 39 | 75X40X6 mm MS Channel,1.2 mtr Long 2 Nos.(6.8Kg/mtr) with Galvanisation charges |
| 40 | 11kv Lighting arrester 9kv,10KA(for 11kv xlpe cable) |
| 41 | Heat shrinkable Jointing Kit for 3CX35 MM2 11 KV XLPE cable (out door type) |
| 42 | LT 3Cx35 MMSQ 11kv XLPE Cable (armoured) |
| 43 | 7/10 SWG GI Stay Wire for support XLPE Cable |
| 44 | 11kv XLPE Cable clamp to hold support wire |
| 45 | Pole clamp for EYE Hook for XLPE Cable |
| 46 | Eye hook for XLPE Cable |
| 47 | Suspension clamp with eye hook for XLPE Cable |
| 48 | Conductor dead end Clamp |
| 49 | GI pipe earthing 40 mm dia medium gauge 3 mtr long. |
| 50 | G.I. Flat (25x4) mm for earthing |
| 51 | H.T Stay set(Complete) |
| 52 | H.T Stay set Insulator Type-C |
| 53 | H.T Stay Clamp |
| 54 | 7/10 SWG Stay Wire(Grade-2) |
| 55 | GI Nut Bolt & Washer |
| 56 | Sundries for survey ,PVC tape Ampire tape,Danger Boardsmall size nut-bolt preparation of drawing etc |
| 57 | CIVIL PART - Construction of brick wall boundary wall with civil &MS material with metal &sand spreading |
| 58 | plinth for 11/0.4,100 kva Substation |
| 59 | Concreting of support CC 1:1.5:3,0.45 CUM@6400 for 11 mtr long WPB Pole |
| 60 | Concreting of support CC 1:1.5:3,0.375 CUM@6400 for 8 mtr long 300kg PSC Pole |
| 61 | Couping with CC 1:1.5:3,0.1125 CUM @6400 |
| 62 | Cement concreting for stay anchor plate with CC 1:2:4,0.2 [email protected] |
| 63 | Material for earthing including masonary work for earth pit, salt , charcoal and cement plate cover |
| 64 | 3P SERVICE CONNECTION - 3.5Cx50 mmsq LT PVC Cable |
| 65 | No8 SWG 4.06mm dia G.I Wire |
| 66 | 200Amp Kit kat fuse |
| 67 | Sundries |
| 68 | Erection of LT OH Line over 8 MTR long200 KG PSC Pole - 8 mtr long 300kg PSC Pole |
| 69 | GI base plate (500X500X10) 20 kg each |
| 70 | Earthing of Support(Coil Type) |
| 71 | Danger Board |
| 72 | Back clamp for Danger Board(25x3)mm flat 0.59kg/mtr flat of 0.510 mtr length,2 nos=(2x0.59x0.510) |
| 73 | GI Barbed Wire(Anticlimbing device@3kg/support) |
| 74 | Back clamp for Anticlimbing device(25x3)mm flat 0.59kg/mtr flat of 0.510 mtr length,8 nos=(8x0.59x0.510) |
| 75 | L.T Stay set(Complete) |
| 76 | L.T Stay set Insulator |
| 77 | L.T Stay Clamp |
| 78 | 7/10 SWG Stay Wire |
| 79 | 3x50+1x35+1x16 mmsq LT XLPE AB Cable |
| 80 | Pole clamp for eye hook |
| 81 | suspention clamp with I hook for ABC |
| 82 | Conductor Dead end clamp |
| 83 | Insulated piercing connector type-B main16 to 95 sqmm to tap 2.5 to 10 sqmm |
| 84 | Neutral connector type-b main35 to 70 sqmm AAAC AND tap tap 2.5 to 10 sqmm service cable cover by black weather resistant insulation cover |
| 85 | GI Nut Bolt & Washer |
| 86 | Sundries for survey ,PVC tape Ampire tape,Danger Board etc. Please Enable Macros to View BoQ information |