| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-05-2026 | Date1 | Date | 23-05-2026 |
| Sl. No. | Item Description |
| 1 | Proposed Development Works for Model Farm at Govt. Krishi Prachetra at Mangurahi District-Sonbhadra (U.P.) |
| 2 | Civil |
| 3 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift up to 1.5 m, as directed by Engineer-in-Charge: |
| 4 | All kinds of soil |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 6 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc., complete. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 8 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 9 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : |
| 10 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : |
| 11 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 12 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 15 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 16 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 17 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 18 | Boring with hydraulic piling rigs with power units, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto the bottom of pile cap): 300 mm dia piles |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 20 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 21 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). |
| 22 | Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 23 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 24 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 25 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 26 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 27 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Foundation above plinth level up to floor V level. |
| 28 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 29 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 30 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 31 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 32 | 1:4 (1 cement: 4 coarse sand) |
| 33 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 34 | 1:6 (1 cement: 6 coarse sand) |
| 35 | 12 mm cement plaster of mix : |
| 36 | 1:6 (1 cement: 6 coarse sand) |
| 37 | 6 mm cement plaster of mix : |
| 38 | 1:3 (1 cement: 3 fine sand) |
| 39 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections |
| 40 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 41 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 25mm thick with 20 mm nominal size stone aggregate |
| 42 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick. |
| 43 | Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. 40 mm wide and 4 mm thick. |
| 44 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 45 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing the joints with white cement mixed with pigment of matching shade complete. |
| 46 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 47 | Size of Tile 600x600 mm |
| 48 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08%and conforming to IS: 15622, of approved brand & manufacturer in all colours and shade in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints(Payment for grouting of joints to be made separately). |
| 49 | Size of Tile 600x600 mm |
| 50 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 51 | 25 mm thick. |
| 52 | Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement. |
| 53 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth. |
| 54 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 55 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 56 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 57 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 58 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 59 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings, glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 60 | Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 61 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 62 | Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 63 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 64 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 65 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 66 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 67 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 68 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 69 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 70 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 71 | Twin rubber stopper |
| 72 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 73 | 250x16 mm |
| 74 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 75 | 250x10 mm |
| 76 | 200x10 mm |
| 77 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 78 | 125 mm |
| 79 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
| 80 | (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 81 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 82 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. |
| 83 | (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 84 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 85 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 86 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 87 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 88 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 89 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 90 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : |
| 91 | 4.0 mm thick glass panes. |
| 92 | Making Drain Along Apron |
| 93 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes. |
| 94 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 95 | Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. Corrugated serrated adjustable ridges |
| 96 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) |
| 97 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 98 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 99 | Foundations, footings, bases of columns, etc. for mass concrete |
| 100 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 101 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 102 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 103 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 104 | Using M.S. angels 40x40x6 mm for diagonal braces |
| 105 | ELECTRICAL |
| 106 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 107 | Group C |
| 108 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 109 | 2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 110 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 111 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 112 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 113 | Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: |
| 114 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 115 | TV antenna socket outlet |
| 116 | Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 117 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 118 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 119 | 1 or 2 module(75mm X 75 mm ) |
| 120 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required. |
| 121 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. |
| 122 | Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. |
| 123 | Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. |
| 124 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 125 | Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. |
| 126 | upto 450 mm sweep. |
| 127 | Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. |
| 128 | Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 129 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 130 | Supplying and fixing following way, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). |
| 131 | 6 way (4 + 18), Double door |
| 132 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 133 | Single Pole |
| 134 | Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 135 | Providing and fixing M.V. danger notice plate of 200 mmx150 mm, made of mild steelm at least 2 mm thick, and viterous enameled whithe on bothe sides, and with incription in single red colour on front side as required. |
| 136 | Supply and fixing 20 amp, 240 volts, SPN industrial Type, socket outlet ,With 2 pole and earth ,metal enclosed plug top along wth 25/32 amp. `C` series SPMCB , in sheet steel encosure, on surface or in recess with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 137 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 138 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 139 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 140 | Upto 35 sq. mm |
| 141 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 142 | 3.5 X 35 sqmm. (32mm) |
| 143 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. |
| 144 | 100 mm Dia |
| 145 | Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq |
| 146 | 35 sqmm 3.5 core |
| 147 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB’s (Four Pole 36 KA with thermal magnatic release) Switches complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB’s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. |
| 148 | The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A & B only. |
| 149 | The minimum clearances between bus bars shall be as follows : |
| 150 | Phase to phase - minimum 20mm |
| 151 | Phase to neutral-minimum 15mm |
| 152 | METER PANEL BOARD |
| 153 | Incoming : |
| 154 | one (1) No.100Amp. MCCB-1No. |
| 155 | Metering : |
| 156 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 157 | One (1) No. (0-100A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 158 | One (1) Set of Phase Indication Lamp. |
| 159 | Bus Bar : |
| 160 | One (1) No.125 A, TPN aluminimum bus bar of suitable length. |
| 161 | Outgoing : |
| 162 | Phase indication lamps on each outgoing to be provided. |
| 163 | 63 Amp. 4PMCB- 4 No. |
| 164 | 16 Amp. SPMCB- 1 No. |
| 165 | 63 Amp. 4PMCB- 1 No. Spare |
| 166 | With meter Space Provision |
| 167 | SUPPLY OF LIGHT FIXTURES : |
| 168 | Supply of 1X17 W mirror light complete in all respects. Make-Philips or Eq |
| 169 | Supply of 12 W LED BULB complete in all respect. Make-Philips or Eq |
| 170 | Supply of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface/Pendent complete in all respect.Make-Philips or Eq |
| 171 | Supply of recess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects.Make-Philips or Eq |
| 172 | Supply of AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.Make: Havells-STANDARD -Refresh Air-SPS |
| 173 | 300mm sweep. |
| 174 | Supply and fixing following rateing four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 175 | 63 A,4P MCB-Bracking Capacity-10 kA, C-Curve-Make-Havells |
| 176 | Supply and fixing of following size of steel conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: |
| 177 | Supplying and fixing following way, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). |
| 178 | 6 way (4 + 18), Double door |
| 179 | Suplying and fixing cable end box(Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution borad, 415 Volts, on surface/recess, complete with testing and commissoning ect. As required. |
| 180 | For 6 way, Double Door TPNMCBDB |
| 181 | Supply and installing of following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, jointed with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required |
| 182 | 450mm width x 62.5mm depth x 2.0mm thickness |
| 183 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 184 | Supplying and Laying of 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 185 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 186 | Supply & fixing of IP 20, Front Lit, Mid Power SMD type LED Light, 1'x1' square shape recess/Surface mounting 18 Watt to 20 Watt, LED Light having Power coated die cast aluminium housing with heat sink, High purity/transmisivity UV Stabilized yellowish diffuser/Refelctor for uniform light distribution, detachable driver set, suitable for 24 Hr Continuous Operation, complete in all respects. |
| 187 | 2160-2400 system lumens,>120 Lm/W, PF>0.95, THD <10% at full load, CRI>80, >300V over voltage protection, 2.5 KV internal Surge Protection, with 5 years warrantee. CAT-AAA |
| 188 | Supply and fixing of LED Tube Light with heavy Duty Metal Box type batten Light Fitting 2x22 watt suitable for upto 2x22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. |
| 189 | 2x2640 system lumens,>120 lm/W, PF>.95, THD<10%, CRI>80, sheet thickness min 0.8mm, Tube with aluminium heat sink, >300V over voltage protection,2.5 KV internal Surge protection, with 5 years Warrantee.CAT. - AAA |
| 190 | Supply and fixing of factory wired integral LED Flood light luminaires with die cast aluminium housing with toughend glass/UV stabilised PC cover and lences built with mandatory driver set suitable for 100 watt to 120 watt. Confirming to IP 66, and IK07 an above protection complete in all respects. |
| 191 | 12000-14400 system lumens, High Power LED with Lenses,>120 lm/W, PF>.95, THD<10%, at full load, CRI>70, Potted driver set in Metal housing(not circuitory) Phase to phase protection at 440V & >300V auto cut and re-start feature, 4 KV internal Surge protection with 5 years Warrantee.CAT. - AAA |
| 192 | Supply, Installation, Testing and Commissioning of L.T. Panel vermin proof floor mounting, M.S. Channel Base with bottom and Fabricated out of 2.0/1.6 mm thik CRCA sheet steel painted with powder coated paint of shade as per the direction of Engineer In charge after proper sheet treatment peocess of sheet steel. The bus bar of panel shall be electrical grade high conductive alluminium alloy of appropriate cross section as per the rating. The main busbar shall be run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus bar suports which shall be mounted on proper interval to ensure the bear the jerks of suport of short cuircuit of 50kA for panels having ACB as Incomer & 36 kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for each Feeder as per 3b construction Format. The panel shall be completed in all respect as per IS 8623 Part 2 & 3. There shall be Seperated metering Component for Incomer metering and Outgoing metering. |
| 193 | All Incomer Feeders shall be provided with Multifunctional metering along with phase Indicating lights and other associated components such as CT control MCB Terminal Blocks etc. and all outgoing Feeders 100 A & above shall be provided with 3 phase Ammeter along with phase Indicating lights and other associates components such as CT control MCB Terminal Blocks etc. The feeder above shall be provided ac accommodated all measuring instrument shall be digital type & all indicating lights ahall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be electricaly operated Draw out Type with microprosser based O/L, S/C & E/F Release off Breking/withstand capacity(ICU/ICs/Icw) 50 kA or more. All MCCB shall be thermal magnetics/microprossor with O/L & S/C protection along with required Spreders Extended rotary handle with pad locking facility of bracking capacity(ICU/ICS) 36 kA or more All MCB shall be Thermal 10kA 'C'Curve Cubical type switch board shall be Cat-A and B only. |
| 194 | Incoming : |
| 195 | 150 Amp. MCCB - 1No |
| 196 | Cat. B Panel Cubicale Type |
| 197 | Metering : |
| 198 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 199 | One (1) No. (0-150A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 200 | One (1) Set of Phase Indication Lamp. |
| 201 | Bus Bar : |
| 202 | One (1) No.200 A, TPN aluminimum bus bar of suitable length. |
| 203 | Outgoing : |
| 204 | Phase indication lamps on each outgoing to be provided. |
| 205 | 63 Amp. 4P MCB- 05 No. |
| 206 | 40 Amp. 4P MCB- 01 No. |
| 207 | 32 Amp. SP MCB- 01 No. |
| 208 | 63 Amp. 4P MCB- 1 No. Spare |
| 209 | 40 Amp. 4P MCB- 1 No. Spare |
| 210 | Supply and fixing following rateing four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 211 | 40 A,4P MCB-Bracking Capacity-10 kA, C-Curve-Make-Havells |
| 212 | 63 A,4P MCB-Bracking Capacity-10 kA, C-Curve-Make-Havells |
| 213 | SANITARY. |
| 214 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required |
| 215 | W.C. pan with ISI marked white plastic seat and lid |
| 216 | Providing and fixing wash basin with C.I. brackets, 15 mm dia C.P. brass Single Hole Basin Mixture approved quality and make ,including painting of fittings and brackets, cutting and making good the walls wherever require. |
| 217 | a) White Vitreous China wash basin size 550x 400 mm with 15 mm dia C.P. brass Single Hole Basin Mixture. |
| 218 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required |
| 219 | 610x510 mm bowl depth 200mm |
| 220 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
| 221 | Semi rigid pipe |
| 222 | a) 32mm dia |
| 223 | b) 40mm dia |
| 224 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 225 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. |
| 226 | 15mm nominal bore |
| 227 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet |
| 228 | a) 100 mm diameter |
| 229 | Providing and fixing CP Brass 32 mm size Bottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. |
| 230 | Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. |
| 231 | a) 15mm dia nominal dia. |
| 232 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 233 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. |
| 234 | Providing and fixing Toilet paper holder |
| 235 | a) C.P. brass |
| 236 | Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc. |
| 237 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. |
| 238 | 110mm diameter |
| 239 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler |
| 240 | 110 mm |
| 241 | Single Tee with Door |
| 242 | Bend 87.5 degree |
| 243 | 110 mm Bend |
| 244 | Shoe (Plain) |
| 245 | 110 mm Shoe |
| 246 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 247 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 248 | 110mm |
| 249 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 250 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. |
| 251 | (internal work) |
| 252 | Exposed on wall |
| 253 | 32mm dia nominal bore |
| 254 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. |
| 255 | 32mm dia nominal bore. |
| 256 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 257 | 20mm dia nominal outer dia pipes |
| 258 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 259 | Concealed work including cutting chases and making good the walls etc. |
| 260 | 15mm dia nominal outer dia pipes |
| 261 | 20mm dia nominal outer dia pipes |
| 262 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 |
| 263 | 15mm nominal bore |
| 264 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 265 | 15mm nominal bore |
| 266 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 |
| 267 | 15mm nominal bore |
| 268 | Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 269 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 270 | 20 mm dia nominal bore |
| 271 | 32mm dia nominal bore |
| 272 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 273 | 25 mm nominal bore |
| 274 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 275 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, |
| 276 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 277 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 278 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 279 | 100mm diameter |
| 280 | 150mm diameter |
| 281 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
| 282 | 100mm diameter S.W. Pipe |
| 283 | 150mm diameter S.W. Pipe |
| 284 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: |
| 285 | 150 x 100 mm. size P type |
| 286 | With Sewer bricks conforming to IS : 4885 |
| 287 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design |
| 288 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 289 | With FPS bricks of class designation 75 |
| 290 | (i) For Sewer Line |
| 291 | Extra for depth of man hole size 90x80 cm |
| 292 | Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. |
| 293 | Extra for depth of man hole size 90x120 cm |
| 294 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design |
| 295 | With 20x20 mm square bar |
| 296 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before with supply and cost of other fIttlings such as elbow,bend,tee and y-tee,Cowel including supply of all marerial labour and T&P. Required for proper completion of work. |
| 297 | 75 mm O.D. |
| 298 | 110 mm O.D. |
| 299 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 300 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. |
| 301 | Size 75/90 mm |
| 302 | Size 110 mm |
| 303 | RENOVATION |
| 304 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: |
| 305 | Of area 3 sq. metres and below |
| 306 | 12 mm cement plaster of mix : |
| 307 | 1:6 (1 cement: 6 coarse sand) |
| 308 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 309 | 1:6 (1 cement: 6 coarse sand) |
| 310 | 6 mm cement plaster of mix : |
| 311 | 1:3 (1 cement: 3 fine sand) |
| 312 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 313 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 314 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 315 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 316 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 317 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 318 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 319 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 320 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 321 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 322 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 323 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 324 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 325 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : |
| 326 | 4.0 mm thick glass panes. |
| 327 | Making khurras 45x45 cm with average minimum thickness of5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 328 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 329 | 110 mm diameter |
| 330 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 331 | Shoe (Plain) |
| 332 | 110 mm Shoe |
| 333 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 334 | 110 mm |
| 335 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 336 | Suuply and fixing Installation of solar security fancing system with chail link (hight : 4+2), GI chain fancing hight-4ft, 1- GI Chainlink Fence Height: 4 Ft. Mesh Gap: 75X75 mm, Thickness: 3.15 mm 2- Main Post Size: 40 mm, Height: 8 Ft. 3- Support Post Size: 32 mm, Height: 6 Ft. 4- Grout: 10X10X24 inches 5- Pole to Pole Distance: 10 Ft. 6- Flat Bar : 30X5 mm, Height:4 Ft. 7- Supporting Wire: 3 Layer (For Chain Link) 8- Tension Bar: 300X10 mm 9-Tension Band GI: 40 mm OD 10- Brace Band GI: 40 mm OD 11- Fencing Wire: 4 Layer 12- Warning Plate: Mid-Size PVC 13- Insulator: Virgin Plastic 14- Wire : HT Wire (Uncut GI) 15- Energizer: Auto 5J GSM Premium Quality (With Alarm) 16- Corner Insulator (Required Area) 17- Wire Tightener: High Grip (Required Area) 18- Tension Spring: Heavy Duty (Required Area) 19- Warning Light:Blinking Mode Red 20- Testing Tool Kit 21- Lighting Diverter 22- Binding Wire: GI 12 Gauge 23- Other Accessories: Solar Panel, Battery Nut, Bolt & Other. |
| 337 | GST Extra as applicable Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail