| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) & for shafts, wells, cesspits and the like not exceeding 10 Sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, incl. all leads and lifts |
| 3 | Providing and laying in position cement concrete of specified grade inclu. curing excluding the cost of centring & shuttering-All work upto plinth level 1:4:8 (1 cement: 4 fine sand : 8 graded stone aggregate 40mm nominal size) incl. all leads, lifts & carriage of material by MT / H.L. |
| 4 | Providing and laying in position cement concrete of specified grade incl.curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) incl. all leads, lifts & carriage of material by MT/ H.L. |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone agg. 20 mm nominal size) incl. all leads, lifts & carriage of material by MT/ H.L. |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases & spiral stair cases upto five level incl. curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 ( 1 cement : 1½ coarse sand :3 graded stone aggregate 20 mm nominal size) including all leads, lifts and carriage of material by MT/ H.L. |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto all level Thermo-Mechanically Treated bars of grade Fe-500D or more incl. all leads, lifts and carriage of material by M.T. / H.L. |
| 8 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth including all shapes, leads, lifts and carriage of material by MT / H.L. in cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 9 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level incl. all leads, lifts & carriage of material by M.T. H.L. |
| 10 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand) including all leads, lifts and carriage of material by MT / H.L |
| 11 | Centering & shuttering including strutting, propping etc. and removal of form for |
| 12 | Foundations, footings, bases of columns etc. for mass concrete. |
| 13 | Suspended floors, roofs, landings, balconies and access platforms |
| 14 | Edges of slabs and breaks in floors and walls under 20 cm wide |
| 15 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)incl. all leads, lifts and carriage of material by M.T. / H.L. |
| 16 | 12mm Cement plaster of mix:1: 4 ( 1 cement : 4 fine sand)incl. all leads, lifts and carriage of material by M.T. / H.L. |
| 17 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 65 mm dia. nominal bore (Medium ) |
| 18 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 50 mm dia. nominal bore medium |
| 19 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work-Exposed on wall 25 mm dia. nominal bore (Medium) |
| 20 | Providing and fixing gun metal non-return valve of approved quality (screwed end) horizontal. |
| 21 | 50 mm nominal bore |
| 22 | 65 mm nominal bore |
| 23 | Supplying of submersible pump set 5HP including wiring complete job |
| 24 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) |
| 25 | 65 mm nominal bore |
| 26 | 50 mm nominal bore |
| 27 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 25 mm nominal bore |
| 28 | Providing and placing on terrace (at all floor levels ) polythylene Water Storage Tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for intlet, outlet and overflow pipes but without fitting and the base support for tank |
| 29 | Structural steel work in welded built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 30 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 31 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 32 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 33 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 34 | Setting up of drilling site by way of shifting of requisite machinery and allied material after making proper approaches as per requirement at site. |
| 35 | Boring/drilling 200mm din. Bore Well, 120 meter below ground level or till sufficient aquifer Zone/discharge is encountered, by using ODEX Method. |
| 36 | Supplying assembly (including welding), lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel beveled ended 200mm dia. casing pipes, conforming to relevant IS code. |
| 37 | Development to tube well in accordance with IS: 2800 (part 1) and IS: 11189 to establish maximum rate of usable water yield without sand content (beyond permissible limit) with required eapacity air compressor, running the compressor for required time till Well is fully developed measuring yield of well by \\"V\\" notch method or any other approved method. |
| 38 | Providing, fitting, installation, testing and commissioning of submersible pump set along with requisite electro-mechanical components such as providing and lowering of G.I. Pipes in to the bore hole, P/f of automatic stator panel, cables etc. |
| 39 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 40 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 41 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 42 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes 110mm dia |
| 43 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/ accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 110mm dia Plain bend |
| 44 | Providing and fixing15 mm dia nominal bore C.P. brass long nose bib cock of approved conforming to IS standards and weighing not less than 810 gms |
| 45 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing |
| 47 | 20mm nominal outer dia pipes. |
| 48 | 25mm nominal outer dia pipes. |
| 49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 50 | 20mm nominal outer dia pipes. |
| 51 | 25mm nominal outer dia pipes. |
| 52 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid |
| 53 | Providing and fixing P.V.C low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete: 10 liter capacity -White |
| 54 | Providing and fixing white vitreous china water closet squatting pan (Indian type) Orrisa pattern size 580 x 440 mm |
| 55 | Providing and fixing 1 mm thick M.S. steel door with frame of 40 x 40 x 6 mm angle iron and 3mm M.S. gusset plates at the junction and corners , all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece. |
| 56 | Installation of SS Water Cooler of 80Ltr. Capcacity (Cold & Normal Water) incl.wiring complete job Please Enable Macros to View BoQ information |