| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (a) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | (b) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Galvanised Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. GI tubes |
| 5 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 6 | P/f polycarbonate sheet of 10mm thick with making all necessary arrangements as per the direction of engineer-in-charge. The sheet shall be fixed using self drilling/self screws with aluminium/GI profiles to fix the sheet complete upto any pitch in horizontal/verticle or curved surfaces, including cutting to size and shape wherever required by engineer-in-charge. |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 8 | 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) |
| 9 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 10 | Neat cement punning. |
| 11 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) 15 mm nominal dia Pipes |
| 12 | (b) 20 mm nominal dia Pipes |
| 13 | (c) 25 mm nominal dia Pipes |
| 14 | P/f evaporative cooling system of 100mm cellulose pads of coldek make with GI tray of 18 gauge with CPVC piping system and drainage of 32mm dia with prefilters with galvanised fastners and aluminium rivets complete as per the specification with 500 lit. PVC tank and 1HP monoblock pump of approved brand as per the direction of engineer-in-charge. |
| 15 | P/f humidification system for humidity range 50% to 90% with 6nos. Of 4 way nozzle foggers with 16mm HDPE black piping (10kg/sqcm) average droplet size 50 to 100 cm with 1HP monoblock single phase pump of approved make with 500 lit. PVC tank over a MS frame with water supply CPVC pipe line of 32/25mm dia pressure meter of 10 bar capacity with Hydro Cyclone filters having leakage prevention device and control valve assembly complete. |
| 16 | P/f 18\\" exhaust fan of approved brand i/c making all necessary arragements as per the direction of engineer-in-charge. |
| 17 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 18 | P/f control panel with complete electrical wiring with copper wire, MCB/main switch/light/power points/ connection with motors/fans and cabling work of aluminium of upto 15m and all related works lije connection etc. as per the direction of engineer-in-charge. |
| 19 | P/f Grow light system (PAR) using special Photo Synthetically Active Radiation Lamp. Intensity with LED of approved make by engineer-in-charge. PAR illumination individual for each section. Please Enable Macros to View BoQ information |