|
| 1 | STEEL WORK |
| 2 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 3 | WATER SUPPLY |
| 4 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall_50 mm dia nominal bore |
| 5 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :_50 to 80 mm nominal bore |
| 6 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :_50 mm nominal bore |
| 7 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :_50 mm nominal bore |
| 8 | RAIN WATER HARVESTING & TUBEWELLS |
| 9 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level._All types of soil_400 mm dia |
| 10 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level._All types of soil_400 mm dia |
| 11 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 12 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. |
| 13 | 150 mm nominal size dia having minimum wall thickness 5.00 mm |
| 14 | 200 mm nominal size dia having minimum wall thickness 5.40 mm |
| 15 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. |
| 16 | 150 mm nominal size dia |
| 17 | 200 mm nominal size dia |
| 18 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 19 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:_200 mm dia |
| 20 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete._200 mm clamp |
| 21 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I)._200 mm dia |
| 22 | MARKET RATE ITEMS |
| 23 | Providing & fixing Galvanized Iron Flange 6 mm to 8 mm thick (Pair) with thread including nuts & bolts with rubber packing as per direction of Engineer Incharge. |
| 24 | Add for revised GST @18% in place of 12% ie 6.33% on SR&DR Total 619107 |
| 25 | ELECTRICAL WORK |
| 26 | Electrical work of borewell, Jamia Enclave, at JMI. |
| 27 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired._2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 28 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 29 | Single pole |
| 30 | Trpal pole |
| 31 | Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 32 | 4 way (4 + 12), Double door |
| 33 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 34 | 100 amps |
| 35 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 36 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 37 | Upto 35 sq. mm |
| 38 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 39 | Upto 35 sq. mm |
| 40 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 41 | Upto 35 sq. mm |
| 42 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 43 | Upto 35 sq. mm |
| 44 | Non Schedule Items |
| 45 | SITC 5 HP 3Phase 25 stage submersible Motor pump vertical type model 7c/25 maximum head 170 meters delivery dia 50 mm KSB/ Crompton Make or Equal Qyality i/c fixing in existing pipe and lowering in borewell etc. as required at site . |
| 46 | Supply, connecting and lowering in borewell/ surface of 3 core 4 sq mm PVC Insulated Copper conductor submersible Flat cable Finolex/ Polycab/ Plaza make or equalant quality as direction by Engineer In- Charge. |
| 47 | Supplying, connecting & lowering in borewell of PVC coated GI wire Rope 6 mm dia good quality as approved by Engineer In-charge. |
| 48 | Supply of 1.1 KV grade XLPE power cable of size 4x35 sq mm Aluminium conductor armoured cable.Polycab/ Gloster/ Havells make as per direction by Engineer In-charge. |
| 49 | Supplying and Fixing LED flood light 100w cool white BVP175 smart bright slim LED light fitting Philips make or same quality Bajaj/ Havells as per approved by Engineer In-charge. |
| 50 | Supply & Fixing 3 phase MU G6 DOL 6-10 Amp. Starter suitable for Motor, L&T make or equalent as approved by Engineer In-charge. |
| 51 | Add on DSR 6.33% Please Enable Macros to View BoQ information |