| 1 | Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 2 | Upto 35 sqmm |
| 3 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 4 | Single pole |
| 5 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 6 | 100 amps |
| 7 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 8 | 63 amps |
| 9 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 10 | 4 X 16 sq. mm (28mm) |
| 11 | Replacement of driver of rating 50 watt , 1.5 A , 240 V in the existing street/flood light i/c connection and dismantling of faulty driver complete as reqd |
| 12 | Replacement of driver of rating 75 watt , 1.5 A , 240 V in the existing street/flood light i/c connection and dismantling of faulty driver complete as reqd |
| 13 | Replacement of PCB of rating 100 watt ,1500 ma 26-36 V in the existing street light/flood light i/c connection and dismantling of faulty PCB connection as reqd |
| 14 | Replacement of PCB of rating 50 watt ,1500 ma 26-36 V in the existing street light/flood light i/c connection and dismantling of faulty PCB connection as reqd |
| 15 | Replacement of PCB of rating 72 watt ,150 ma, 6 V in the existing street light/flood light i/c connection and dismantling of faulty PCB connection as reqd |
| 16 | Replacement of driver of rating 100 watt , 0.7 A , 240 V in the existing street/flood light i/c connection and dismantling of faulty driver complete as reqd |
| 17 | Supplying of one number XLPE insulated and PVC sheathed / XLPE copper conductor un armoured power cable of 650/1.1 KV grade of size 3C x 2.5 sqmm etc as required. |
| 18 | Supply and fixing of street light pole box of size (250 X 200 X 100) complete with all necessary accessories including suitable clamps, bakelite sheet, brass screws, washers, and 01 no. 10 Amps SP MCB (Single Pole Miniature Circuit Breaker), inclusive of making electrical connections, as required at site. |
| 19 | Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm in existing single box or double box fittings complete as required. Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 20 | Supplying of one number XLPE insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade of size 4C X 16 sqmm etc as required. Please Enable Macros to View BoQ information |