| 1 | 1.Cleaning and Grubbing roadClearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be use dor auctioned, upto a lead of 1000 m Including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. A) In area of non thorny jungleRate as per SOR Rural roads 2020-21 |
| 2 | 2.E/W in EmbankmentConstruction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto p g q p1000 m as per Technical Specification Clause 301.5 By Mechanical Means, Private Land Quantity as per SOR 2020-21 |
| 3 | 3.E/W in Sub-Grade & ShoulderConstruction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site,spreading,grading to required slope and compacted to meet requirement of Table 300.2 with lead upto1000 m as per Technical Specification Clause 303.1.i) Private LandQuantity as per statement Rate as per SOR 2020-21 |
| 4 | 4.G.S.B., Gr-IIConstruction of granular sub-base by providing well graded material,spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.For Grading II MaterialQuantity as per statementRate as per Annexure - I |
| 5 | 5.Sign Board & Traffic Sign Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2nos.75 mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450 mm x 450 mm x 600mm, 600 mm below groundlevel. The top most diamond plate will be welded to middle plate by 47 mm x 47 mm of 12 SWG steel plate tube. AllMS. will bestove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 6 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600mm, 600 mm below groundlevel as per drawings and Technical Specification Clause 801(ii) 60 cm equilateral triangle |
| 7 | (iii) 60 cm circular |
| 8 | 6.PlantationPlanting of Trees and their Maintenance for three Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trenches, watering , fixing the tree guard and maintaining the plants for three year. |
| 9 | 7. RCC Box Culvert Size : 4.00m x 4.00m, 3 CellEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out,construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I Ordinary Soil, upto 3 m depth |
| 10 | Sand Filling in foundation trenches as per drawing and Technical Specification 305.3.9 |
| 11 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause802, 803, 1202 & 1203A With crushed Stone:I) P.C.C grade M 10Nominal mix 1:3:6 |
| 12 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause802, 803, 1202 & 1203A With crushed Stone:II) P.C.C. Grade M20i) Nominal Mix 1:2:4 |
| 13 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204A.With Crushed Stoneiv) RCC Grade M 25(i) Height upto 5m |
| 14 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5A With crushed stoneII R.C.C grade M 25 a) Height upto 5M |
| 15 | Construction of R.C.C. railing of M25 grade incast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 16 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 17 | Supplying, fitting and placing TMT (Fe-500D) reinforcement bar . (From Primary Producer: TATA/SAIL/EsserSteel/Jindalsteel/Shyamsteel/RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 18 | Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3A. With Crushed stone : |
| 19 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 20 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8A. Granular Materials |
| 21 | Providing and laying curtain walls complete as per drawing and Technical Specifications clause 1304iii) Cement concrete grade M10 |
| 22 | Drainage spouts complete as per drawing and technical specifications Clause 1209 |
| 23 | Construction of flexible apron 1m thick comprising of loose stone boulders weighing not less then 25 kg beyond curtain wall |
| 24 | Providing pressure relief pipes 100 mm dia in bottom slab of box cell on a filter media base of 500 mm x 500 mm as per drawing and technical specification Clause 1205.5.7 |
| 25 | P.C.C. M15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211A) With Crushed stone i) Nominal Mix (1 : 2.5 : 5) |
| 26 | Reinforced Cement Concrete M25 grade approach slab including reinforcement and form work complete as per drawing and technical specifications Clauses 800 and 1211A) With Crushed stone |
| 27 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 28 | Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301 |
| 29 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 |
| 30 | Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 |
| 31 | RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed.b) 15 cm dia. RCC guard post with reinforcement of 4nos. 12mm dia TMTmain steel bars and 6mm TMT/ MS stirrups at 15cm c/c. |
| 32 | Construction of temporary Bamboo bridge of 3.70 m clear roadway with Bholukaor Barua Bamboo post 5 nos. in each rows driven at least 180 cm. belowground level and rows not more than 150 cm apart from center to center Bholuka or Barua Bamboo dham longitudinal groth both closely placed and tied with half bamboo 90 cm to 120 cm apart in both layers and two layers of jati bamboo chattais (top layer should be digonally woven), 70 mm to 100 mm thick brushwood in between chattias should be tied with half jati bambooo n both ends, bamboo railing with bholuka or barua bamboo post placed at 150 cm apart jati or betua bamboo hand rails of two lines both side of every alternate rows. All tying must be done with cane or coir string and only mature bamboo should be used in work. Please Enable Macros to View BoQ information |