| 1 | Taking out split type air conditioners indoor and out door units complete for repair/ servicing and overhauling of capacity 1.5/2.0 TR of any make/type after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay, capacitors, thermostat, strainer etc and also including carrying out servicing, overhauling and connecting of refrigerant pipe,drain pipe and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed. Note :- (i) Spares as mentioned will be measured and paid separately as supply only items (ii) Refrigerant gas will be measured and paid separately only. |
| 2 | Supply and Fix sealed compressor of split type air conditioner of 1.5 TR capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make : Voltas/Hitachi/Tecumseh/LG/Blue Star |
| 3 | Supply and Fix only sealed compressor of split type air conditioner of 2.0 TR capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make:Voltas/Hitachi/Tecumseh/Kirloskar/LG/Blue Star |
| 4 | Supply and Fix MS wall bracket suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed Make:- As per sample |
| 5 | Leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering,flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in split type air conditioner upto 1.5 TR /2 TR capacity and testing complete all as specified and directed Note:- Refrigerant will be measured and paid separately. |
| 6 | Supply and charging refrigerant gas (R-134a/R-410a/R-407 or superior ) suitable for Refrigerators/water coolers/Deep freezers and cold room Air conditioners etc complete all as specified and directed. Make: Mafron or equivalent makes as approved by the GE. |
| 7 | Supply charging refrigerant gas (R-22 ) suitable for split/window ) complete all as specified and directed. Make: Mafron or equivalent makes as approved by the GE. |
| 8 | Supply charging refrigerant gas (R-32 ) suitable for split/window ) complete all as specified and directed. Make: Mafron or equivalent makes as approved by the GE. |
| 9 | Supply only relay assembly suitable for split type air conditioner 1.5/2.0 TR capacity complete all as specified and directed. Make:- As per sample |
| 10 | Supply and Fix fan motor with blade suitable out door unit split type air conditioner up to 2 TR capacity complete all as specified and directed. Make:- As per sample |
| 11 | Supply only relay contactor No 1622 suitable for split type air condtioners upto 1.5/2 ton capacity complete all as specified and directed. LG/Samsung/Carrier/Blue star/Hitachi |
| 12 | Supply and Fix blower fan motor with blade for out door unit including capacitor,single phase, 230V,50Hz for split type air conditioner upto 2 TR capacity complete all as specified and directed. Make : Usha/ AUE/Siemens/Keltron or equivalent any make with ISI marked Make:- As per sample |
| 13 | Supply starting capacitor 80 to 100 mfd for split type air conditioners complete all as specified and directed. Including taking down old one and fixing.Make : Concap/Keltron/Asian/Tesla/sarda/Siemens/tibcon |
| 14 | Supply running capacitor 36 -60 mfd for split type air conditioners complete all as specified and directed.including taking down old one and fixing. Make : Make : Concap/Keltron/Asian/Tesla/sarda/Siemens/tibcon |
| 15 | Supply only universal strainer air filters cum dryier suitable for 1 to 2 ton Split Air conditioners of any type complete all as specified and directed Make:- As per sample |
| 16 | Taking down remote control unit PCB board from indoor unit of split type AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed. |
| 17 | Taking down remote control unit PCB board from indoor/outdoor unit of split type dual inverter AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed.Make LG |
| 18 | Taking down remote control unit PCB board from indoor/outdoor unit of split type dual inverter AC of 1.5/2.0 TR capacity replace and refix it with new one and testing complete all as specified and directed.Make LG/Daikin/haire etc |
| 19 | Removing the old unserviceable swing motor of any type and supply and fix new swing motor of 1.5/2.0 TR capacity split type ACs complete all as specified and directed.Make:- As per sample |
| 20 | Removing the old acoustic padding and supply and fix new acoustic ('U' form) padding with all packing material for refrigerant tubing from outdoor unit to indoor unit after dismantling copper tube and re fix again all as specified and directed. |
| 21 | Taking out the old unserviceable PVC drain pipe from wall to ground at any height and including its fittings and supply and fix new PVC pipe 15 mm dia, ISI marked including bends, tees, elbows, sockets, saddles, etc for condensed water complete all as directed. |
| 22 | Taking out the old unserviceable capillary tube 0.064 inch and supply and fix new capillary tube with strainer for the split type ACs 1.5/2 TR capacity complete all as specified and directed. |
| 23 | Disconnecting and taking out the old unserviceable copper tubing and supply and fix copper tube of size 3/8\\" dia including necessary soldering, flaring work and jointing testing for any type of cooling appliances complete all as directed. |
| 24 | All as per item No 25 above but size of copper tube 1/2\\" dia complete all as specified and directed |
| 25 | All as per item No 25 above but size of copper tube 1/4\\" dia complete all as specified and directed |
| 26 | All as per item No 25 above but size of copper tube 5/8\\" dia complete all as specified and directed |
| 27 | Removing the old unserviceable copper cable after disconnecting electrical connections and supply and fix PVC insulated,sheathed,multistandard round flexible ,1100 volts grade copper conductor cable of size 4 sqmm;3 core complete all as specified and directed.Make:- Finolex/Havells/Plaza/Polycab |
| 28 | Removing the old unserviceable copper wire after disconnecting electrical connections and supply and fix PVC insulated,sheathed,multistandard round flexible ,1100 volts grade copper conductor FRLSH wire of size 2.5 sqmm;1 core complete all as specified and directed.Make:- Finolex/Havells/Plaza/Polycab |
| 29 | Removing the old unserviceable defective hand remote control for split AC of Cap 1.5/2 TR and supply only new hand remote control with 2 Nos batteries, 1.5 Volt of size 'AAA\\" (Make -Suitable for existing make)and testing complete all as specified and directed |
| 30 | Dismantling of the Window /split type air conditioner of capacity complete set 1.5/2.0 TR from the existing position and shifting the same to the new altered location, complete indoor and outdoor units, refrigerant tubing, MS stand, stablizer and cable etc and testing complete all as specified and directed |
| 31 | Removing the unserviceable 3 pin industrial plug top and supply and fix new 3 pin industrial plug top, ISI marked suitable for industrial metal clad socket, single phase, 240 volts,20 Amps including connecting complete all as specified and directed |
| 32 | Removing old unserviceable condenser coil assembly from split type air conditioner upto 2 TR capacity supply and fix copper condenser coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed. |
| 33 | Removing old unserviceable cooling coil assembly from split type air conditioner upto 2 TR capacity supply and fix copper cooling coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed. |
| 34 | Removing old unserviceable 2-3 way refrigerant control valve from split air conditioner outdoor unit after evacuating of refrigrant gas and supply and fix 2-3 way valve suitable for split type ACs of capacity upto 2 TR and testing complete all as specified and directed. |
| 35 | Removing old unserviceable split type air conditioner indoor unit and deposited in store yard for safe custody and Supply and fix indoor unit of the split type air conditioner 1.5 TR capacity and complete with all accessories such as installation plate with screws, blower motor, swing motor, filters etc duly prewired and including connecting of existing refrigerant piping, electrical connections, drain pipe and testing etc complete all as specified and directed.Make: Carrier/LG/Hitachi/Blue star/Voltas. |
| 36 | Removing old unserviceable split type air conditioner outdoor unit and deposited in store yard for safe custody and Supply and fix outdoor unit of the split type air conditioner 1.5 TR capacity, complete with all accessories such as hermetically sealed compressor and condenser unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refrigerant gas piping, electrical connections and testing etc complete all as specified and directed. Make: Carrier/LG/Hitachi/Blue star/Voltas. |
| 37 | Supply only capacitor 30 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos/Universal/Tipcon |
| 38 | Supply only capacitor 45 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos/Universal/Tipcon |
| 39 | Supply only capacitor 36 mfd complete all as specified and directed.Make: Asian/ KEL/Epcos/Universal/Tipcon |
| 40 | Taking out window type air conditioner for servicing and overhauling of capacity 1.5/2.0 TR of any make/type after disconnecting of electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, strainer including carrying out servicing,overhauling and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed. Note :- (i) Spares will be measured and paid separately as supply only items (ii) Refrigerant gas will be measured and paid separately |
| 41 | Replacing the corroded outer casing with base tray sheet of the window type air conditiner of capacity upto 2 TR of any type/ make and supply and fix outer casing with base sheet made out of GI sheet suitable to window type air conditioner of capacity upto 2 TR complete all as specified and directed.Make:- As per sample |
| 42 | Leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in window type air conditioner upto 2 TR capacity and testing complete all as specified and directed. |
| 43 | Supply and Fix over load protector suitable for window type air conditioners Make : Usha/Shriram/Sarda |
| 44 | Supply and fix sealed compressor of window type air conditioner of 1.5 TR capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make: LG/Voltas/Hitachi/Tecumseh/Kirloskar/LG/Blue Star. |
| 45 | Supply and fix sealed compressor of window type air conditioner of 2.0 TR capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make: LG/Voltas/Hitachi/Tecumseh/Kirloskar/LG/Blue Star. |
| 46 | Supply only starting capacitor 80 to 100,100 to 120 mfd for window type air conditioner complete all as specified and directed. Make : Concap/Keltron/Asian/Tesla/sarda/Siemens/tibcon |
| 47 | Supply only running capacitor 40,50,60 mfd for window type air conditioner complete all as specified and directed. Make : Concap/Keltron/Asian/Tesla/sarda/Siemens/tipcon |
| 48 | Supply and Fix blower fan motor with blade including capacitor,single phase, 230V,50Hz for window type air conditioner upto 2 TR capacity complete all as specified and directed. Make : Usha/ AUE/Siemens/Keltron or equivalent any make with ISI marked Make:- As per sample |
| 49 | Supply and Fix fan motor with blade suitable fo window type air conditioner up to 2 TR capacity complete all as specified and directed. Make:- As per sample |
| 50 | Supply only relay contactor suitable for existing window type air condtioners upto 1.5/2 ton capacity complete all as specified and directed. LG/Samsung/Carrier/Blue star/Hitachi |
| 51 | Supply only relay assembly No 1622 suitable for window type air conditioner 1.5/2.0 TR capacity complete all as specified and directed. Make:- As per sample |
| 52 | Taking down remote control with 2 Nos batteries (1.5 Volt of size 'AAA\\") PCB board from window type AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed.Make:- As per sample |
| 53 | Supply and Fix thermostat switch for window type / Split type AC any type make upto 2 TR capacity complete all as specified and directed. Make: INDOFOSS/ RANUTRAL/Annapurna |
| 54 | Supply and Fix selector switch rotary type suitable for window type AC upto 2.0 TR capacity complete all as specified and directed.Make : Fedderlloyd/Arco/Usha/Voltas/Rotar Switch. |
| 55 | Supply only contactor, AC, 230 volts ,50Hz, suitable for Window ACs upto 2.00 TR capacity complete all as specified and directed.Make:- As per sample |
| 56 | Taking out old unserviceable front side grill cover and supply and fix plastic or acrylic front side grill cover for window type AC upto 2.0 ton capacity of various makes etc complete all as specified and directed. |
| 57 | Removing old unserviceable condenser coil assembly from window type air conditioner upto 2 TR capacity & supply and fix copper condenser coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed. |
| 58 | Removing old unserviceable cooling coil assembly from window type air conditioner upto 2 TR capacity & supply and fix copper cooling coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed. |
| 59 | Material and labour for spray painting to window type air conditioner of any type /make with two coats of synthetic enamel paint over a coat of red oxide primer after removal of existing treatment and preparation of surfaces and including removing dents complete all as specified and directed. |
| 60 | Taking out water cooler for servicing and overhauling 40/80 ltrs, 40/120 ltrs, 40/160 ltrs capacity of any make/type after disconnecting of electric connection, removing dust by using blower and cleaning all the components by using water and caustic soda, checking and replacing the spares like relay, capacitors,gasket, thermostat, PVC pipes, push cock/liftcock, float valves etc and also including carrying out servicing,overhauling and charging of refrigerant gas and testing and fixing back in its original location complete all as specified and directed. |
| 61 | Replacing the corroded portion of the water cooler & servicing of capacity 440/80 ltrs, 40/120 ltrs, 40/160 ltrs capacity of any type/ make and providing the same gauge sheet in corroded portion by bending/welding, soldering and painting the replaced portion to match with existing colour and also providing base support legs complete all as specified and directed. |
| 62 | Material and labour for spray painting to water coolers 40/80 ltrs, 40/120 ltrs, 40/160 ltrs of any type /make with two coats of synthetic enamel paint over one coat of red oxide primer after removal of existing treatment and preparation of surfaces and including removing dents complete all as specified and directed. |
| 63 | Supply and fix hermetically sealed compressor for water cooler 40/80 Litres capacity including initial filling of refrigerant gas to the required pressure and testing, also including removing the old unserviceable compressor complete all as specified and directed Make: Voltas/Blue Star /Tecumseh/Kirloskar/Usha. |
| 64 | Supply and fix hermetically sealed compressor for water cooler 60/120 litres capacity including initial filling of refrigerant gas to the required pressure and testing, also including removing the old unserviceable compressor complete all as specified and directed. Make: Voltas/Blue Star/Tecumseh/Kirloskar/Usha |
| 65 | Leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in watercooler upto 40/80 ltrs, 40/120 ltrs, 80/160 ltrs cooling capacity and testing complete all as specified and directed. |
| 66 | Supply and fix blower fan motor for water cooler upto 160 Ltrs capacity & testing including removing old unserviceable item complete all as specified and directed.Make:- As per sample |
| 67 | Supply only capacitor 10-20 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos |
| 68 | Supply and fix PVC out let drain connecting pipe of 15 mm bore with brass nuts and washers of length n.exc. 60 cms for connecting of water coolers complete all as specified and directed.Make:- As per sample |
| 69 | Supply and fix in repairs push cock / lifting cock of brass chromium plated15mm bore self closing type with back plate for water cooler of any capacity complete all as specified and directed. |
| 70 | Supply and fix in repair float valve assembly 15 mm dia with PVC body, polythene float suitable for water cooler complete all as specified and directed. |
| 71 | Removing old unserviceable condenser coil assembly from water cooler any type 20/40 to 100/150ltr capacity and supply and fix copper condenser coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed. |
| 72 | Supply and fix fan motor with blade including capacitor,single phase, 230V,50Hz for water coolers complete all as specified and directed. Make : Usha/ AUE/Siemens/Keltron or equivalent any make with ISI marked |
| 73 | Supply and fix relay assembly suitable for water coolers capacity complete all as specified and directed. |
| 74 | Supply only thermostat switch for water coolers any type/ make complete all as specified and directed. Make: INDOFOSS/ RANUTRAL |
| 75 | Supply and fix pillar taps, cast copper allay with capstan head, chromium plated, screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly-nuts screwed for 15mm dia iron pipe complete |
| 76 | Disconnecting and taking out the old unserviceable copper tubing and supply and fix copper tube of size 1/3\\" dia complete all as specified and directed .suitable for water cooler of capacity 80 Ltrs. |
| 77 | Taking out Refrigerator for servicing and overhauling from 165 litre to 352 ltr capacity (single door/Double door type) of any make/type after disconnecting of electric connection and cleaning all the components, checking and replacing the spares like relay, capacitors, thermostat,fused bulb and also including carrying out servicing, oiling, greasing and charging of refrigerant gas and testing complete all as specified and directed. Note :- (i) Spares will be measured and paid separately as supply only. (ii) Refrigerant gas will be measured and paid separately as supply only. |
| 78 | Leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in Refrigerator upto 352 ltr capacity and testing complete all as specified and directed. |
| 79 | Supply and fix sealed compressor of Refrigerator upto 185 litres capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make: Voltas/Kelvinator/Tecumseh/Kirloskar/Usha/Godrej |
| 80 | Supply and fix sealed compressor of Refrigerator 210 to 352 litres capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make: LG/Voltas/Kelvinator/Tecumseh/Kirloskar/Usha/Godrej / Videocon/ samsung |
| 81 | Supply only relay assembly suitable for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed. |
| 82 | Supply & fix bi-metal switch for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed. Make:- LG/samsung/Videocon/Godrej/Whirlpool |
| 83 | Supply & fix condensor coil suitable for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed. |
| 84 | Supply & fix cooling coil suitable for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed. |
| 85 | Supply & fix fan motor with blade suitable for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed. |
| 86 | Supply & fix metal refrigerator stand suitable for refrigerator of any type/capacity complete all as specified and directed |
| 87 | Supply & fix capacitor 6 to 10 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos/Tipcon |
| 88 | Supply & fix thermostat switch for refrigerators of any capacity/ any type/ make complete all as specified and directed. Make: INDOFOSS/ RANUTRAL/Annapurna |
| 89 | Supply & fix heating element 20 to 40 watt for refrigerators of any capacity/ any type/ make complete all as specified and directed. Make: INDOFOSS/ RANUTRAL/Annapurna |
| 90 | Removing old unserviceable capilary copper tube of size 0.031\\" (Inch) and supply and fix new capilary copper tube suitable for existing type/make/size complete all as specified and directed. |
| 91 | Removing old unserviceable acrylic plastic chillar tray's such as suitable for Vegitable side fixing tray's,ice cube tray's etc complete all as specified and directed. Make:- As per sample |
| 92 | Removing old unserviceable bulb from refrigerator of watt/capacity and supply and fix new bulb suitable for existing type/make/capacity/size complete all as specified and directedMake:- As per sample |
| 93 | Fan Motor with blade, single phase,230V AC 50 Hz for Deep Freeze of any make of capacity 200/400 Ltr Make As per samle |
| 94 | Supply and Fix anti bacterial gasket set including magnet if required for refrigerator doors of any capacity / type/any make (As per sample) complete |
| 95 | Taking out deep freezers for repairs/servising to Deep Freezer of capacity 150 to 400 Ltr of any make and any type by replacing unserviceable compressor and other parts from the machine as directed including charging of Refrigerant gas after vacuuming and making system leak proof. Brazing the suction / discharge tubes where required and cleaning of Condensing unit to achive proper cooling effect. Checking of electronic circuit of machine and repair where necessary by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing complete. |
| 96 | Supply only Capacitor of any capacity for deep freezer of capacity 150 to 400 Ltr. |
| 97 | Supply onlyThermostatic switch suitable for Deep freezer of capacity 150 to 400Ltr (Make : Indfos/ Denfoss/ Ranutal/Annapurna |
| 98 | Supply only relay suitable for Deep Freeze Make As per samle |
| 99 | Supply and fix an Motor with blade, single phase,230V AC 50 Hz for Deep Freeze of any make of capacity 200/400 Ltr Make As per samle |
| 100 | Supply and fix sealed compressor for deep freezer 150 to 400 litre capacity including initial filling of refrigerant gas to the required pressure and testing, also including removing the old unserviceable compressor complete all as specified and directed. Make: Voltas/Blue Star/Tecumseh/Kirloskar/Usha |
| 101 | Leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in Deep freezer upto 300/400 ltr capacity and testing complete all as specified and directed. |
| 102 | Supply & Fix sheet metal enclosure single door 240 volts AC,SPN distribution board 2 way painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN incomer and MCB SP/DP as out goings and complete with 200 Amps rated busbar ,neutral bar,earth bar connecting cable links with top and bottom removable gland plate complete with IP 42 protection all as specified and as directed. |
| 103 | Supply and fix flat sleek smooth 25 A motor starter for AC including cutting fixing of concealed MS 2M box with cover and finishing as directed. |
| 104 | Supply and concealed fixing socket 3 pin 25 A for AC including cutting fixing MS 2m box with cover plate including all other necessary items. |
| 105 | Supply & fix for MCB SP 6 to 32 Amps 10 KA,\\"C\\" series complete all as specified and directed. |
| 106 | Supply & fix MCB DP 40 Amps 10 KA,\\"C\\" series complete all as specified and directed. |
| 107 | Attending water leak complain of Air conditioning /other cooling appliances unit and solve the problem after dismantling and checking sloping if required re locate indoor unit fo rgetting slope to drain pipe ,cleaning the cabinet ,PVC drain pipe etc applying tape in joint and laying /sloping the drain pipe properly and fix the problem.(if drain pipe required it will be measured and paid separetely) |
| 108 | Attending cooling appliances complain and solve the problem.it will be consider where there is no requirment of any material.rete is only for taking job card from department and fix the prob at ground and deposit the job card duly signed by user to department. |
| 109 | Supply and fix new stainer in place of choked old one for any type of cooling appliances |
| 110 | M & L for water,dust and direct heat proof cover of split AC outdoor unit of any description as per direction of Engineering In Charge |
| 111 | Taking down voltage stabilizer any make of capacity upto 5 KVA Single Phase by replacing unservicabe parts and refixing the same in working condition on existing location . |
| 112 | Material and labour for taking down old vintage rusted broken deep Deep freezer of capacity 320 ltr,supply same with glass top. |
| 113 | Supply and fixing of voltage stabilizer 0.5 KVA for refrigerator/watercooler etc having operating voltage range 130 VAC to 290 VAC. Please Enable Macros to View BoQ information |