|
| 1 | Demolition of brick work built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engr-in-Charge. |
| 2 | Demolition of cement concrete in ground floors and pavings n. exc. 15 cm thickness (Below or above ground level) complete and removing of unserviceable material out side MD land exceeding 5.00 Km and cleaning site , complete all as specified and directed by Engr-in-Charge. |
| 3 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. and removing of unserviceable material out side MD land exceeding 5.00 Km and cleaning site, complete all as specified and directed by Engr-in-Charge. |
| 4 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 5 | Taking down cement plaster of any description on brick or stone walls etc, including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed by Engr-in-Charge. |
| 6 | S&F 1.25 mm thick steel rolling shutters without ball bearing or gear operated type with bevel gear box and crank handle as specified, including top cover, anchoring rod, hasp & staple and one coat of primer and two coats of synthetic enamel paint; erected in position as indicated including taking down complete all as specified and as directed by Engr-in-Charge. |
| 7 | M&L for Brick work with Fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for Brickwork with subclass ‘B’ bricks, (Except Bricks) straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for providing cement concrete Type B-0 (1:2:4) (12.5mm graded crushed stone aggregate) as in copings, bed plates, bed block & hold fasts etc. including necessary form work complete all as specified and directed by Engr-in-Charge. |
| 10 | M&L for precast (Factory made) cement concrete blocks Type B-1 (1:2:4) (20mm graded crushed stone aggregate) as in bed blocks, kerbs etc, setting in cement mortar 1:4, dismantling old kerb stone and removing out side defence land, complete all as specified and directed. |
| 11 | M&L for rendering cement plaster 15 mm thick in Cement Mortar 1:4 other than fair faces of brick work or concrete surfaces, is to be finished fair & even without using extra cement including necessay scafolding complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for Rough cast plaster including After applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick with WPC @1% and while it is still in plastic state, the roughcast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered including necessay scafolding complete all as specified and directed by Engr-in-Charge. Note :- WPC shall be measured and paid separetely. |
| 13 | Supply only integral WPC as per manufacturer's instructions complete all as specified. |
| 14 | M&L for keyed pointing to brick wall in cement mortar (1:3) complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L for broken glass coping on top of walls in cement mortar (1:3) complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L for preparation of new / old surface of wall and making smooth by using sand paper applying two coat of exterior acrylic emulsion (weather proof treatment) including one coat of exterior primer including necessary scaffolding complete all as specified and as directed. |
| 17 | M&L for preparation of old surface of wall and applying one coat of exterior acrylic emulsion (weather proof treatment) including necessary scaffolding complete all as specified and as directed. |
| 18 | M&L for 75 mm thick Cement concrete type B- 1, 1:2:4 (20mm graded crushed stone aggregate) as in plinth protection /flooring complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L for 28 mm Wide Plastic dividing strips, 1.5mm thick, inserted in position, conform to design complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for PCC (1:4:8) type D-2 (40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 21 | M&L spike rolling to surface or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed by Engr-in-Charge. |
| 22 | M&L 25 mm sand cushioning for interlocking tiles including well rammed and consolidation all as per direction by Engr-in- Charge. |
| 23 | M&L for rubberised machine pressed pre polished precast concrete interlocking paver block any shape, size, desired colour and pattern conforming to IS 15658-2006 of 60 mm thickness M-30 grade with grey cement and pigment, complete all as specified and directed by Engr-in Charge. |
| 24 | All as per item No. 23 here-in-before but refixing old dismantling interlocking tiles, complete all as specified and directed. |
| 25 | M&L Chequred cement pre polished concrete tiles 400X 400X 25 mm thick of desired pattern and colourset, jointed and pionted in neat cement slurry in floors with grey cement and pigment including 20 mm thick screed bed cement mortar 1:6 including dismatling complete all as specified and directed by Engr-in-Charge. |
| 26 | Excavating in trenches not exceed 1.5 mtr wide and not exc 1.5 mtr in depth for foundation etc or for shafts, wells cess pit, man holes pier holes etc not exceed 10 Sqm on plan and not excced 1.5 mtr in depth and getting out in soft / loose soil complete all as specified and directed by Engr-in-Charge. |
| 27 | Returning , filling in , including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-Charge.. |
| 28 | Removing excavated material exc. 1.5 Km but n. exc. 5.00 Km and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 29 | M&L Framed work as in doors/ gates/ chajjas of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to 6 Fe 410-W (Gde E- 250) - A quality. |
| 30 | S&F for Fibre glass reinforced translucent corrugated sheeting of thickness 2mm with two corrugations side lap fixed with coach screw and washer in roof, wall etc. including taking down complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L for preparation of new steel surface of any description over 10 cm in width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed by Engr-in-Charge. |
| 32 | M&L for coloured designer Parking Matt finished Tiles 12-15 mm thick, Size 400 x400mm over and Including 15 mm thick screed bed in Cement Mortar 1:6 set, jointed in floors& pointed in neat cement slurry with gray cement and pigment in floors including dismantling and removing the debris outside the defence land complete all as specified and directed.Make: Johnson and Johnson /Kajaria/Somany/Orient. Note: MTC to be provided by contractor |
| 33 | Taking down steel / iron gates area not exc 10 Sqm each including hold fasts and re fixing the gates in the same opening including shifting and fixing of existing holdfast in plain cement concrete (1:2:4), type B-1 after raising the gate level including greasing and repair of gate, including one coat of synthetic enamel paint and other necessary minor repairs complete all as specified and as directed. |
| 34 | S&F factory made precast RCC manhole cover slab with and incl frame designation LD 2.5, clear opening of frame size (1.20m x 0.60m x 0.075m) thick ISI marked (IS-12592:2002) (As approved by GE) complete all as specified and as directed. Make : VENUS/ HARIOM TILES AND PAVER/ MOHINDRA & SV RCC. |
| 35 | M&L Preparation of old steel or iron surfaces over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specifeid and directed by Engr-in-Charge. |
| 36 | M & L for applying texture paint of 4mm thick of desired finish as approved by GE over a coat of exterior wall primer which includes preparation of old decorated surfaces, cleaning of loose paint, grease, growth of fungus, algae or moss by using wire brushing and watering and applying two coats of exterior emulsion paint including necessary scaffolding complete all as specified and directed. Make for texture paint - Asian paint apex duracast crosstex (horizontal scratch/vertical scratch/criss cross/rainfall), or equivalent in Berger or Nerolac (For bldg from GF to 3rd Floor). |
| 37 | Material and labour for 20mm thick grit plaster (marble) in two layers, consisting of a 12mm thick under-layer of cement mortar 1:4 (1 cement : 4 coarse sand) finished with a furrowed surface to provide a key, followed by an 8mm thick top-layer comprising a mix of 1:2 (1 white cement : 2 marble grit of 6mm to 10mm size and approved colour) mixed with a water-proofing compound at 2% by weight of cement; the top-layer is applied over a white cement slurry (2 kg/sqm), compacted, and subsequently scrubbed with a nylon or wire brush and washed with water after the initial set to uniformly expose the marble grit, all measured in square metres (sqm) and cured for a minimum of 7 days as per MES Standard Schedule of Rates (SSR) specifications including taking down old plaster complete all as specified and directed. |
| 38 | Supply & fix MS angle iron or tee sections, framed brackets of angles or tees,(not exceeding 10 Kg each bracket) conforming to Fe-290.Grade-E-165, purlins for fixing roof / fixing sheets as in chhajjas with coach screws and washers with 20mm wide x 3mm thick tie to frame work and fixed to walls/supports by means of dash screw bolts of suitable size including distance pieces, cleats etc. and welding complete all as specified and directed. |
| 39 | Material & Labour for providing galvalume chajja of anticorresive prepainted /colour coated base sheet of thickness 0.50mm TCT having high tensile strength not less than 550Mpa yield strength CR steel base metal with hot dip alloy coating of A1 Zn-Si as per ASTM-A-792 M-02/AS-1397 ALU-SINC alloy sheet shall be of alloy of 55% Aluminium +43.5 % zink+1.5 % silicon. The total coating of alloy shall not be less than 150 gms per sqm (AZ) 150) as per ASTM 792 of AS 1397 with top coat of 20 micron s (DFT) over 5 micron (DFT) or epoxy primer and back coat with 5 Micron (DET) epoxy primer. The sheet shall be fixed to purlin with self drilling and self topping screw confirming to AS 3566of ITW Bolldex corroshield make with moulded EPDM washer including dismantling old sheets complete all as specified and directed by Engr-in-Charge. |
| 40 | M&L for Removing of debris/loose soil exceeding 5.00 Km from the starting out side MoD land from the complete all as specified and directed by Engr-in-Charge. |
| 41 | Note :- Amount of credit of Rs. 24000.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender. Please Enable Macros to View BoQ information |