| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard/Dense soil complete all as specified and directed by the engr in charge. |
| 2 | M&L for Cement concrete in foundations, filling and mass concrete Type D2 1:4:8 (40 mm graded aggregate) complete all as specified and directed by the engr in charge. |
| 3 | M&L for Pre-cast cement concrete block Type C1 1:3:6 (20mm graded aggregate ) masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete Set in cement mortar 1:4 complete all as specified and directed by the engr in charge. |
| 4 | M&L for Rendering in 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces to be finished even and smooth (without using extra lime or cement) complete all as specified and directed by the engr in charge. |
| 5 | M&L for Rendering in 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces to be finished even and smooth (without using extra lime or cement) complete all as specified and directed by the engr in charge. |
| 6 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the engr in charge. |
| 7 | Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by the engr in charge. |
| 8 | M&L for RCC Type B0 1:2:4 (12.5mm graded graded aggregate) as in lintels Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by the engr in charge. |
| 9 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for Rough finished surfaces of concrete complete all as specified and directed by the engr in charge. |
| 10 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by the engr in charge. |
| 11 | M&L for Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes complete all as specified and directed by the engr in charge. |
| 12 | M&L for Butt hinges 50 mm long, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed by the engr in charge. |
| 13 | M&L for Flue pipes 250 mm dia of mild steel sheet, black, in suitable lengths as approved by the E.I.C. fixed to walls complete all as specified and directed by the engr in charge. |
| 14 | M&L for Cowls 250mm (with 3 stays), riveted to and including 15 cm length of flue pipes, of ditto complete all as specified and directed by the engr in charge. |
| 15 | M&L for Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by the engr in charge. |
| 16 | M&L for two coats of synthetic enamel paint over a coat of red oxide Surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed by the engr in charge. |
| 17 | M&L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point as in soils complete all as specified and directed by the engr in charge. |
| 18 | M& L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in hard/dence soil complete all as specified and directed by the engr in charge. |
| 19 | M&L for Three coats White wash on new perpared wall surfaces complete all as specified and directed by the engr in charge. |
| 20 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard and dense soil complete all as specified and directed by the engr in charge. |
| 21 | Rolling and consolidating formation surfaces in cutting with power roller exc 5 tonn but not exc 8 tonn complete all as specified and directed by the engr in charge. |
| 22 | M & L for 75mm Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers , watered and rammed to a true surface complete all as specified and directed by the engr in charge. |
| 23 | M & L for PCC 1:4:8 type D2 using 40mm graded crushed agg 100 mm thick over rammed earth as in sub base of hard standing complete all as specified and directed by the engr in charge. |
| 24 | M & L Sand cushioning 25mm thick under paving blocks incl watering and consolidation complete all as specified and directed by the engr in charge. |
| 25 | M & L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment complete all as specified and directed by the engr in charge. |
| 26 | S & F Providing and laying at or near ground level factor made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of jointsexcept at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete complete all as specified and directed by the engr in charge. |
| 27 | M&L for Preparation of stone surfaces of any description over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel based paint over a coat of priming coat complete all as specified and directed. |
| 28 | Taking down carefully aluminium/Copper point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge. |
| 29 | Taking out old unsv submain wiring of any size/make/ type etc from excavted tranches/ on pole passing through pipes etc from different locations complete all as specified and directed by the engr in charge. |
| 30 | M&L for Wiring for circuit/submain wiring alongwith earth wire with the 2x10.0 sq. mm + 1x10.0 sq. mmearth wire of FRLS is PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC Conduit all as specified and directed by Engineer in Charge. |
| 31 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-(a) One light point/one fan point controlled by one switch |
| 32 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-(b) One 3 pin 5 amps socket outlet independent with cables 2.5 sqmm size |
| 33 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-(c) One 3 pin 5 Amp socket outlet on same board with cables 2.5 sqmm size |
| 34 | All same as per item No 32 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable complete all as specified and directed by the engr in charge. |
| 35 | S&F Socket 2 in 1, 5 pin 5 Amp flush type complete all as specified and directed by Engr In Charge. |
| 36 | S&F Switch piano flush type 5 Amp, single pole, one way complete all as specified and directed by Engr in Charge. |
| 37 | S&f Switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed by Engr in Charge . |
| 38 | S&F Switch Socket Combination 2 in 1, 3 pin, 15/16 amp flush type Universal complete all as specified and directed by Engr in Charge . |
| 39 | M&L for ceiling rose surface Bakelite 65x50mm two to three terminal complete all as specified and as directed by Engr-in-Charge. |
| 40 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified complete all as specified and directed by the engr in charge. |
| 41 | S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 10 watt, 2 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXACP7IN1W010 or equivalent in Philips/Crompton) |
| 42 | S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 20 watt, 4 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXAXPNIN1W020 or equivalent in Philips/Crompton) |
| 43 | S&F in repair sheet metal powder coated versatile Double door SPN distribution board, 16 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz all as directed by Engr in Charge. |
| 44 | M&L in repair for MCB SPN 63 Amp, 240V with 10KA breaking capacity of 'C' series in distribution boards all complete all as specified and directed by the engr in charge. |
| 45 | S&F in repair MCB SP 6-32 Amp with 10KA breaking capacity of 'C' series in distribution boards with all accessories complete all as per specified and as directed by Engr-in-Charge. |
| 46 | Dismantling and Taking down old u/s street / building sequrity Light fittings from poles, flood lights, post top lantern lights and garden lights for replacement with LED fittings all as specified and as directed by Engr in Charge. |
| 47 | Supply and fix LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete Specified and directed by Engr in charge. |
| 48 | M&L for GI bracket 1.5 mtr long made out of GI pipe 40mm dia bend to suitable radius incl clamps nuts bolts washers incl painting with aluminum paint etc complete all as specified and directed by Engr in charge. |
| 49 | Supply and fix in replacement exhaust fan, steel body body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm AC single phase with, blades, and frame and louvers of size 300 mm sweep all as per specified and as directed by Engr-in-Charge. |
| 50 | M & L in repair for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to MS galvanized earh strip of size 25 x 4 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, GI strip laid in dia 40 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit (30X30X30cm) with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified complete all as specified and directed by Engineer-In-Charge. Please Enable Macros to View BoQ information |