| 1 | Taking out old serviceable/unserviceable LT UG cables of size 10 to 70 sqmm 3.5/4 core from trenches, poles/walls and floor including taking out old unserviceable/serviceable bricks covers/GI pipe of any size from trenches for removing or re-laying (after necessary repair/jointing) the cable complete all as specified and directed by Engr-in-Charge. |
| 2 | All as per item No 01 here-in-before but size of 95 to 300 sqmm 3.5 core complete all as specified and directed by Engr-in-ChargeNote for Item No 1 & 2 : Earthwork and excavation shall be measured and paid separately. |
| 3 | Supply and laying XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor including necessary lugs, glands as required of following size in trenches or fixed on wall/floor/poles complete all as specified and directed.(a) 16 Sqmm 4 Core |
| 4 | (b) 25 Sqmm 3.5 Core |
| 5 | (c) 35 Sqmm 3.5 core |
| 6 | (d) 50 Sqmm 3.5 Core |
| 7 | (e) 95 Sqmm 3.5 Core |
| 8 | (f) 185 Sqmm 3.5 Core |
| 9 | (g) 300 Sqmm 3.5 Core |
| 10 | Re-laying XLPE UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 to 70 Sqmm 3.5/4 core (item retreived from item No 7 here-in-before) laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 11 | All as per item No 10 here-in-before but size of 95 to 300 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge |
| 12 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of HT/LT underground cable, pole or stay and getting out in Hard soil complete all as specified and directed. |
| 13 | All as per item No 12 here-in-before but exc 1.5 mtr and n.exc 3.0m in depth for erection of pole etc complete all as specified and directed by Engr-in-Charge |
| 14 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as directed by Engr-in-Charge |
| 15 | Removing excavated surplus soil to a distance not exceeding 50 metre and deposting where directed at a level not exceeding 1.5 metre above the the starting point complete all as specified and directed by Engr-in-Charge |
| 16 | Supply and lay in trenches un-reinforced precast concrete cable cover class LV type I of size 250 x 150 x 40mm for cable protection all as specified and directed by the Engr-in-Charge. |
| 17 | Material and labour for riddled earth filling in trenches to required width at bottom and top of cable as cushioning including spreading leveling and consolidation complete all as specified and as directed. Note : Punned thickness shall measured and paid |
| 18 | Material and labour for cutting of grass/bushes surounding the area of substation/out door type feeder pillar box 4 pole stracture and remove the deposited materials to a distance not more than 50 mtr away from the site including cleaning the out side and inside of the sub station building and making the surface clean complete all as specified and directed by Engr-in-Charge. |
| 19 | Surface excavation in soil for taking out pebbles including removing vegetation and bushes not exceeding 30cm depth & averaging 75mm deep in sub station complete all as specified and directed. |
| 20 | Material and Labour for hardcore of gauge 40 mm deposited, spread & levelled in layers n. exc 15 cm thick, watered & rammed to a true surface with broken stone or boulders complete all as specified and directed. |
| 21 | Supply install testing and commissioning of 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete with explusion fuses, GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps,each pole consist of galvanised steel base HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformers. All ferrous parts hot dipped galvanised and non ferrous parts suitablly tinned to withstand weather complete including taking down existing Unserviceable AB switch all as specified and directed.Make:- Jaipuriya Brothers or Pactil |
| 22 | All as per item No 21 above but current rating upto 400 Amps |
| 23 | Supply and Fix Polymer based dropout fuse unit complete set suitable and including for 22 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning complete including taking down existing Unserviceable fuse all as specified and directed |
| 24 | Supply and fix lightining arrester suitable for 18 KV station class including taking down old unserviceable set all as specified and directed by Engineer-in -Charge. |
| 25 | Material and Labour in repair for ACSR conductor (Ferret) jumper connections of following lengths both ends secured with suitable aluminium lugs or one end with AI lugs and other end plain for binding with conductor encased with polythene sleeve, RYB colours of suitable dia complete all as specified and directed for :-a) Not exceeding 0.75 meter length. |
| 26 | b) Exceeding 0.75 meter length but not exceeding 1.5 meter length. |
| 27 | c) Exceeding 1.5 meter length but not exceeding 2.5 meter length. |
| 28 | d) Exceeding 2.5 meter length but not exceeding 3.0 meter length. Please Enable Macros to View BoQ information |
| 29 | d) Exceeding 2.5 meter length but not exceeding 3.0 meter length. Please Enable Macros to View BoQ information |