| 1 | M&L for servicing/cleaning of complete indoor and outdoor unit of Split Type Air conditioner of AC 2.0 TR capacity/Window AC by means of adding cleaning solution with water, cleaning of the condenser and chiller tubes shall be clean with use of nylon brushes till the scaling is removed and ensuring its serviceability of rectification/ renewal of unserviceable parts and keeping AC in serviceable working condition complete all as specified and directed. Note:- Supply of spares for replacement will be measured and paid separately under relevant items. |
| 2 | All as per ser item No 01 here-in-before but split/ Window type AC 1.5 TR |
| 3 | M&L for taking out unserviceable compressor any type of Split type AC 1.5 Ton capacity from site and replacement of compressor against repair of existing make and re-fixing the compressor sealed unit in position, charging of refrigerant gas R-22/410 of required quantity, bracing of discharge and suction line and leak testing complete all as specified and directed. |
| 4 | All as per ser item No 03 here-in-before but for Split Type AC 2 Ton capacity. |
| 5 | S&F in renewal PCB card for indoor unit of same model and make suitable for 1.5 TR Capacity Split AC/Inverter type Split AC units complete all as specified and directed. |
| 6 | All as per ser item No 05 here-in-before but for Split type AC 2 Ton capacity. |
| 7 | S&F in renewal PCB card for outdoor unit of same model and make suitable for 1.5/2 TR capacity split AC invertor type units complete all as specified and directed. |
| 8 | S&F in renewal fan motor for indoor unit of same model and make suitable for 1.5 TR capacity split type AC units complete all as specified and directed. |
| 9 | All as per ser item No 08 here-in-before but Split Type AC 2 Ton capacity. |
| 10 | S&F in renewal outdoor motor AC/DC of same model and make suitable for 1.5/2 TR capacity complete all as specified and directed. |
| 11 | S&F in renewal Fan Blower of indoor unit of split AC 1.5/2 TR complete all as specified and directed. |
| 12 | Dismantling old and unserviceable air swing fan motor and replacing with new one suitable for 1.5/2 ton capacity split AC complete all as specified and directed. |
| 13 | Dismantling old and unserviceable reverse valve and replacing with new one suitable for 1.5/2 ton capacity split AC complete all as specified and directed. |
| 14 | Dismantling old and unserviceable sensors and replacing with new one suitable for 1.5/2 ton capacity split AC complete all as specified and directed. |
| 15 | S&F in renewal of hard drawn copper pipe size suitable for existing one and connection with indoor to outdoor unit of AC plant along insulating rubber sleeves and including brazing complete all as specified and directed. |
| 16 | M&L for gas charging with R-22/410 for split type AC in position including leak testing to achieve desired suction pressure and temperature (or any other cooling appliances also) complete all as specified and directed. Note:- Gas leakage due to unserviceable of reverse valve and copper tube will be refilled by the contractor at his own cost. |
| 17 | S&F in renewal of Thermostate for Deep freezer/Refrigerator of size suitable for existing one complete all as specified and directed. |
| 18 | S&F in renewal of compressor for Deep Freezer of capacity 500 Ltrs complete all as specified and directed. |
| 19 | All as per ser item No. 18 here-in-before but Deep freezer of capacity 400/300 Ltrs complete all as specified and directed. |
| 20 | S&F in renewal of compressor for Refrigerator with gas filling of any capacity complete all as specified and directed. |
| 21 | S&F in renewal of relay of suitable amp for Refrigerator/ deep freezer complete all as specified and directed. |
| 22 | Supply only remote control system of split/ window type AC of capacity 2/1.5 TR complete all as specified and directed. |
| 23 | S&F running capacitor 45/60 manufacturer for Split type Air conditioner 1.5 Ton capacity complete all as specified and directed. |
| 24 | M&L puff insulation to suction pipe of split AC complete all as specified and directed. |
| 25 | S&F in renewal copper wound Automatic voltage stabilizer, single phase naturally air-cooled indoor type & designed for input variation between 90V to 220V with output voltage stabilized upto 240V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed. |
| 26 | S&F in renewal voltage stabilizer for Automatic operation, single phase naturally air-cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized upto 230V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed. |
| 27 | S&F in renewal plug top 15 Amps complete all as specified and directed. |
| 28 | S&F in renewal plug top 5 Amps complete all as specified and directed. |
| 29 | S&F connecting cord 1.5 mtr length with plug top suitable for 1.5 Ton split/Window AC complete all as specified and directed. |
| 30 | All as per ser item No. 29 here-in-before but split/Window type AC 2 TR. |
| 31 | M&L wiring kit suitable for windows type ACs of any capacity and make complete all as specified and directed. |
| 32 | M&L OLP for any type of AC/deep freezer/refrigerator of any capacity & make complete all as specified and directed. |
| 33 | S&F in repair flat plate collector suitable for Solar Hot Water System based on indirect transfer of heat of capacity 100 LPD all as specified and directed by Engr-in-Charge. |
| 34 | S&F in repair flat plate collector suitable for Solar Hot Water System based on indirect transfer of heat of capacity 200 LPD all as specified and directed by Engr-in-Charge. |
| 35 | S&F in repair flat plate collector suitable for Solar Hot Water System based on indirect transfer of heat of capacity 300 LPD all as specified and directed by Engr-in-Charge. |
| 36 | Taking down carefully copper/aluminium point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc., removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc. complete all as specified and directed. |
| 37 | M&L for point wiring in PVC casing capping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws gutter/plug etc. PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor complete all as specified and directed. |
| 38 | S&F switch piano flush type, single pole16 Amps 240 Volts, complete all as specified and directed. |
| 39 | S&F socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and as directed. |
| 40 | S&F in repair backup stainless steel hot water tank duly insulated suitable for Solar Hot Water System of capacity 100 LPD all as specified and directed by Engr-in-Charge. |
| 41 | S&F in repair backup stainless steel hot water tank duly insulated suitable for Solar Hot Water System of capacity 200 LPD all as specified and directed by Engr-in-Charge. |
| 42 | S&F in repair backup stainless steel hot water tank duly insulated suitable for Solar Hot Water System of capacity 300 LPD all as specified and directed by Engr-in-Charge. |
| 43 | S&F in repair copper pipe/tube suitable for use in Solar Hot Water System of size 1/4\\" all as specified and directed by Engr-in-Charge. |
| 44 | S&F GI tubing 20mm medium grade, ISI Marked complete with all fittings and fixtures laid in trenches or laid under floors, fixed on walls with and providing clamps etc. complete all as specified and directed by Engr-in-Charge. |
| 45 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation, laying of cables, etc. and getting out in hard/dense soil complete all as specified. |
| 46 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm depth in soil complete all as specified and directed. |
| 47 | Removing excavated material (soil) n.exc 50m and depositing where directed at a level n.exc. where directed at a level n.exc. complete all as specified. |
| 48 | S&F in repair bib taps 20 mm dia, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-Charge. |
| 49 | S&F in repair stop valves 20 mm , cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge. |
| 50 | S&F in repair heating element of capacity 1.5KW (Round/Triangle) complete all as specified and directed. |
| 51 | S&F in repair heating element of capacity 2KW (Round/Triangle) complete all as specified and directed. |
| 52 | S&F in repair heating element of capacity 3KW suitable for 100/200/300 ltr Solar Water Heater all as specified and directed. |
| 53 | S&F in repair thermostat suitable for 25/50 Ltr Geyser complete all as specified and directed by Engr-in-Charge. |
| 54 | S&F in repair thermostat suitable for 100/200/200 Ltr Solar Water Heater Plant complete all as specified and directed by Engr-in-Charge. |
| 55 | M&L for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and directed.Note :- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment. |
| 56 | M&L for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and directed.Note :- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment. |
| 57 | Servicing of geysers of any capacity by opening of entire geyser and cleaning all the sludges, blockages, dust, etc. complete all as specified and directed by Engr-in-Charge. |
| 58 | S&F in repairs PVC connecting pipe 18\\" long with brass adopters for Hot/Cold water and connecting up with complete for 25 /35 / 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe. Complete all as specified and directed by Engr-in-Charge. |
| 59 | S&F fusible plug melting at 90 - 100 degrees Centigrade including taking down existing unserviceable fusible plug complete all as specified and directed by Engineer-in-Charge. |
| 60 | S&F high pressure valve with dead weight suitable for 25 / 50 ltrs capacity geysers including taking down existing unserviceable high pressure valve complete all as specified and directed by Engineer-In-Charge. |
| 61 | S&F bottom covers (set of two halves) duly painted made out of Aluminium / MS sheet of 18 SWG suitable for 25 / 35 / 50 ltrs capacity geysers including taking down existing unserviceable bottom covers complete all as specified and directed by Engineer-in-Charge. |
| 62 | S&F base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly complete all as specified and directed by Engineer-in-Charge. |
| 63 | M&L for repairs to water heater inner vessel including brazing, welding, testing for a pressure of 3kg / Sq.cm., re-assembling of any capacity geysers complete all as specified and directed by Engineer-in-Charge. |
| 64 | S&F plug top 15A 24V complete all as specified and directed. |
| 65 | M&L for servicing and repairing Kero-Cum Electric based Hot water plant of any capacity and make all as specified and directed by Engr-in-Charge. |
| 66 | S&F Photo-Cell suitable for 500 Ltr Hamam complete all as specified and directed. |
| 67 | S&F 6 controller suitable for 500 Ltr Hamam complete all as specified and directed. |
| 68 | S&F Fuel Pump suitable for 500 ltr Hamam complete all as specified and directed. |
| 69 | S&F in repair Nozzle suitable for 500 Ltr Hamam complete all as specified and directed. |
| 70 | S&F in repair Ignition Coil suitable for 500 Ltr Hamam complete all as specified and directed. |
| 71 | Topping up of glycol concentrate along with the necessary additives and inhabittor in cognition and supplied in barrels, the mixture freezing temperature should be -30 Degree complete all as specified and directed. |
| 72 | Repair/renewal of hot water plant comprising of 07 number hot water generator of Rapid cool / Western Make capacity 1,00,000-150000 KCal/Hour and central heating system 100000 Kcal/hr for 80 ORS at Gulmarg including renewal of worn out defective parts all as specified & directed.(i) Disconnecting electrically, drain out of water, opening of boiler front cover, blower assembly all accessories & mounting of boiler & taking out helical coil Make : Rapid cool hot water generator 100000 KCal/Hour, cleaning with pressure wash and chemical agent of heating coil, repairing/ replacing refactory and reassembling of the same after replacing fiberglass gasket necessary repairing/replacement of unserviceable parts complete including all minor repairs such as welding, brazing etc. all items like nuts, bolt and washers etc. all as specified and directed. |
| 73 | Overhauling of oil fired glycol based hot water generator burner assembly including renewal/repairing of Fuel pump, motor coupling, ignition electrodes, Sequence controller, fuel nozzle, solenoid valve, Photo cell, fuel lines and fuel filter, hot generator servicing with welding and gypsum suitable for burner with PCC 1:4:8 alongwith iron guard complete all as specified and directed. |
| 74 | Repairing/renewal of wiring of panel with spare parts like 3 phase contactor, relay, contactor switch, indication lamp, wire thimble etc. complete all as specified and directed. |
| 75 | S&F single phase contactor 240V complete all as specified and directed. |
| 76 | S&F three phase contactor 415V complete all as specified and directed. |
| 77 | Opening of the front cover and descaling of helical coil/fire tubes with pressure wash complete all as specified and directed. |
| 78 | S&F fiberglass front cover gasket and waterline gaskets suitable for hot water boiler complete all as specified and directed. |
| 79 | S&F refractory plate repair/renewal with ceramic material and compound front side side as complete all as specified and directed. |
| 80 | S&F digital temperature controller suitable for boiler with sensor complete all as per complete all as specified and directed. |
| 81 | S&F micro processor based temperature controllers of hot glycol generators, all as specified. |
| 82 | Descaling of FOU heating coils cleaning of air filters including dismantling the blower motor and renewal of blower bushes, complete all as specified and directed. |
| 83 | Dismantling and overhauling of gear type transformer pumps including renewal of oil seals as required complete all as specified and directed. |
| 84 | S&F microprocessor based temperature indicator cum controller oil level indicator with 12 Volts transformer level controller complete with fuel tank of capacity 20 litres, oil filter assembly, propeller fan and wiring and stainless steel front grill of size 1200mmx1200mm, complete all as specified and directed. |
| 85 | M&L for repairing of leakage in the hot water circuit of MS pipes and PPR pipes at various places including supplying and fixing of gaskets, PPR tees, elbows, connector, ferrule, the job shall include electric welding, fusion welding as required complete all as specified and directed. |
| 86 | Supply ,laying and testing 20mm dia pipe steel water tubing medium grade, galvanized with screwed socket joints together with all fittings such as Bends, Elbows, Tees, Short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc. and fixing complete including short lengths, cutting, screwing and waste and for making forged and bends on piping as required including taking up or down steel tubing and connections complete all as specified and directed. |
| 87 | All as per ser item No 86 here-in-before but size 25mm dia pipe. |
| 88 | M&L for GI gate valves, heavy duty, with iron wheel head, screwed both ends (ISI marked) of size 15 mm dia complete all as specified and directed. |
| 89 | M&L for GI gate valves, heavy duty, with iron wheel head, screwed both ends (ISI marked) of size 20 mm dia complete all as specified and directed. |
| 90 | M&L for GI gate valves, heavy duty, with iron wheel head, screwed both ends (ISI marked) of size 25 mm dia complete all as specified and directed. |
| 91 | M&L for GI globe or gate valves, heavy duty, with iron wheel head, screwed both ends (ISI marked), class-II of size 40mm dia complete all as specified and directed. |
| 92 | M&L for GI globe or gate valves, heavy duty, with iron wheel head, screwed both ends (ISI marked), class-II of size 50mm dia complete all as specified and directed. |
| 93 | Supplying laying and testing , connecting, and fixing of polypropylene random copolymer aluminium foiled 32 mm bore OD pipe or composite pipes complete with fittings duly insulated with 13mm thick closed cell elastomeric insulation 30 to 40 kg/cum density of hot glycol fluid pipes complete all as specified and directed. |
| 94 | All as per ser item No 93 here-in-before but size 25mm bore OD pipe |
| 95 | S&F sluice valve 80mm bore PN 1.6 complete all as specified and directed. |
| 96 | S&F sluice valve 50mm bore PN 1.6 complete all as specified and directed. |
| 97 | M&L for bib tap 20mm bore complete all as specified and directed. |
| 98 | S&F booster pump 1.5 HP complete all as specified and directed. |
| 99 | M&L for GI Union of size 20mm complete all as specified. |
| 100 | M&L for GI Union of size 15mm complete all as specified. |
| 101 | M&L for GI Elbow of size 20mm complete all as specified. |
| 102 | M&L for GI Elbow of size 15mm complete all as specified. |
| 103 | M&L for GI Socket of size 20mm complete all as specified. |
| 104 | M&L for GI Socket of size 15mm complete all as specified. |
| 105 | M&L for GI Reducing Tee of size 20x15mm complete all as specified. |
| 106 | M&L for GI Nipple of size 15mm and 80mm long complete all as specified. |
| 107 | M&L for GI Nipple of size 15mm and 100mm long complete all as specified. |
| 108 | M&L for GI Nipple of size 20mm and 80mm long complete all as specified. |
| 109 | M&L for GI Nipple of size 20mm and 100mm long complete all as specified. |
| 110 | M&L for welding work for MS water storage tank to prevent leakages etc. complete all as specified and directed. |
| 111 | S&F of thermostatic valve suitable for radiators complete all as specified and directed. |
| 112 | M&L for repairing of Pump of capacity 1/2 HP with material like mechanical seal , bearing, washers etc. and Rewinding of electric motor if required complete all as specified and directed. |
| 113 | M&L for repairing/rewinding of circulator Pump of capacity 3 HP with material like mechanical seal , bearing, washers etc. and rewinding of electric motor if required complete all as specified and directed. |
| 114 | Repairing/Rewinding of Pump of capacity 5 HP with material like mechanical seal , bearing, washers etc. and rewinding of electric motor if required complete all as specified and directed. |
| 115 | S&F circulation pump of capacity 2.5 HP alongwith necessary flange and gland packing and accessories complete all as specified and directed. |
| 116 | S&F in repair 80mm pipe of glass wool /nitrile rubber insulation over hot water piping complete all as specified and directed. |
| 117 | All as per ser item No 116 here-in-before but size 63 mm complete all as specified. |
| 118 | All as per ser item No 116 here-in-before but size 40 mm complete all as specified. |
| 119 | All as per ser item No 116 here-in-before but size 20 mm complete all as specified. |
| 120 | M&L for servicing, leak testing and fixing of radiator unit complete all as specified and directed by Engr in charge. |
| 121 | S&F in renewal of Balance valve 3\\" dia complete all as specified and directed. |
| 122 | S&F in renewal flange rubber gasket of size 3\\" as per sample complete all as specified and directed. |
| 123 | S&F in renewal fuel pipe of CHS as per sample complete all as specified and directed. |
| 124 | S&F in renewal oil filter of CHS as per sample complete all as specified and directed. |
| 125 | S&F in renewal Air release valve 1/2\\" dia of CHS as per sample and complete all as specified and directed. |
| 126 | S&F in renewal Burner air motor suitable for 1,00,000 K Cal/Hr CHS complete all as specified and directed. |
| 127 | S&F Hot Blower suitable for 1,50,000 K Cal/Hr CHS complete all as specified and directed. |
| 128 | S&F in renewal Glycol Circulator pump suitable for 1,00,000 K Cal/Hr CHS or as per sample complete all as specified and directed. |
| 129 | S&F in renewal Hot Water Circulator pump suitable for 1,00,000 K Cal/Hr CHS as per sample complete all as specified and directed. |
| 130 | S&F in renewal of Swing motor of Fan Coil unit suitable for 1,00,000 K Cal/Hr CHS complete all as specified and directed. |
| 131 | S&F in renewal 25 mm dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. Please Enable Macros to View BoQ information |