| 1 | Sch 'A' Part-I (Building Work & 300 MTR Long Baffle Range )Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5. |
| 2 | Total amount of Sch 'A' Part II (Site clearance, Excavation and Earth work) |
| 3 | Total amount of Sch 'A' Part III (Internal Water Supply ) |
| 4 | Total amount of Sch 'A' Part IV (Internal Electrification) |
| 5 | Total amount of Sch 'A' Part V (Road, Path, Culvert And Hard Standing) |
| 6 | Total amount of Sch 'A' Part VI (Area Drainage) |
| 7 | Total amount of Sch 'A' Part VII (Sewage Disposal) |
| 8 | Total amount of Sch 'A' Part VIII (Security Wall, Compound Wall, Chain Link Fencing And Gate) |
| 9 | Total amount of Sch 'A' Part IX (External Water Supply ) |
| 10 | Total amount of Sch 'A' Part X (External Electrification) |
| 11 | Sch 'A' Part - XI (Miscellaneous Items for B/R & E/M Works)Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as \\"Rs 0.00 under col.5 siginifies this fact only. |
| 12 | Internal Water SupplyS&F 16mm outer dia 3-layer PP-R Polypropylene (random copolymer) concealed pipe SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot &cold water supply including all PP-R plain & brassthreaded Polyproplene random fitting fixed complete to walls, ceiling or in floors etc. complete all as specified and directed. |
| 13 | S&F 20mm outer dia 3-layer PP-R Polypropylene (random copolymer) concealed pipe SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot &cold water supply including all PP-R plain & brassthreaded Polyproplene random fitting fixed complete to walls, ceiling or in floors etc. complete all as specified and directed. |
| 14 | S&F 25mm outer dia 3-layer PP-R Polypropylene (random copolymer) concealed pipe SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot &cold water supply including all PP-R plain & brassthreaded Polyproplene random fitting fixed complete to walls, ceiling or in floors etc. complete all as specified and directed. |
| 15 | Making connection of PP-R distribution branch with PP-R main of size 16 mm to 40 mm size by providing and fixing tee including cutting and making fusion joint etc.complete all as specified and directed. |
| 16 | Fixing only 25 mm outer bore metal stopcock gunmetal gate valve, brass ball valve gunmetal non- retrning valve in PP-R pipe line (cost of maie sockets included).complete all as specified and directed. |
| 17 | Supply only 25 mm outter dia PP-R Gate valves (brass insert) as per requirement of the site. complete all as specified and directed. |
| 18 | Supply only 25 mm PP-R Ball valve (brass insert) as per requirement of the site. complete all as specified and directed. |
| 19 | Supply & fix Heaith faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 20 | INTERNAL ELECTRIFICATIONM&L for Point wiring complete for One light/ceiling fan/Exhaust fan point controlled by one way switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core cable including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof /floor suitable for modular switch with suitable size modular metal flush box not less than 1.20mm thick with inner and outer cover plate & frame etc of required colour complete, including PVC insulated multistanded ISI marked unsheathed FRLSH cable 1100 volts grade of size 1.50 sqmm single core FRLSH copper conductor cable as earth wire connected to common earth dolly etc. complete all as specified and directed.Note :-(a) Colour code of cable Phase-Red, Neutral- Black and Earth-Green. (b) All switch of security light should be near stair case front side. |
| 21 | M&L for Point wiring complete for One 5 pin 5 Amp switch socket outlet point on independent board with PVC insualted and unsheathed FRLSH cable 2.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core cable including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof /floor suitable for modular switch with suitable size modular metal flush box not less than 1.20mm thick with inner and outer cover plate & frame etc of required colour complete, including PVC insulated multistanded ISI marked unsheathed FRLSH cable 1100 volts grade of size 1.50 sqmm single core FRLSH copper conductor cable as earth wire connected to common earth dolly etc. complete all as specified and directed.Note :-(a) Colour code of cable Phase-Red, Neutral- Black and Earth-Green. (b) Height of socket should be 1.20 m above from floor. |
| 22 | M&L for Point wiring complete for Power point controlled by one switch with PVC insualted and unsheathed FRLSH cable 2.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core cable including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof /floor suitable for modular switch with suitable size modular metal flush box not less than 1.20mm thick with inner and outer cover plate & frame etc of required colour complete, including PVC insulated multistanded ISI marked unsheathed FRLSH cable 1100 volts grade of size 2.50 sqmm single core FRLSH copper conductor cable as earth wire connected to common earth dolly etc. complete all as specified and directed.Note :-(a) Colour code of cable Phase-Red, Neutral- Black and Earth-Green. |
| 23 | S&F Exhaust fan, 300 mm sweep made of sturdy engineering plastic complete with lovers shutters, 240 volts,min 1200 RPM complete and mounted in suitable opening arrangement in wall and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and fixed with nuts,bolts and washers and grouted in wall in CM(1:3), complete all as specified.Note :- (i) Sereial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |
| 24 | S&F Exhaust fan, 300 mm sweep made of sturdy engineering plastic complete with lovers shutters, 240 volts,min 1200 RPM complete and mounted in suitable opening arrangement in wall and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and fixed with nuts,bolts and washers and grouted in wall in CM(1:3), complete all as specified.Note :- (i) Sereial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |
| 25 | S&F Exhaust fan, 300 mm sweep made of sturdy engineering plastic complete with lovers shutters, 240 volts,min 1200 RPM complete and mounted in suitable opening arrangement in wall and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and fixed with nuts,bolts and washers and grouted in wall in CM(1:3), complete all as specified.Note :- (i) Sereial Number as issued by Engr-In-Charge of Exaust fan and GE Office name shall also be written on fan with red colour permanent marker cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |
| 26 | Blanking plate of plastic (suitable for distribution board). |
| 27 | M&L for submain wiring comprising single core ,2 Runs of 6 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC conduit of size min 25 mm dia, ISI Marked and its fittings concealed in floor/roof/walls complete including provision of 1X6 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS complete all as specified and directed by Engr-In-charge.Note : 1 Meter of Pipe including fitting and 3 Runs of single core cable shall be measured as Unit Runing Meter.Additional wire/cable required for connecting to MCB shall be included in overall cost quoted. |
| 28 | M&L for submain wiring comprising single core ,2 Runs of 1.5 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC conduit of size min 20 mm dia, ISI Marked and its fittings concealed in floor/roof/walls complete including provision of 1X1.5 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS complete all as specified and directed by Engr-In-charge.Note : 1 Meter of Pipe including fitting and 3 Runs of single core cable shall be measured as Unit Runing Meter.Additional wire/cable required for connecting to MCB shall be included in overall cost quoted. |
| 29 | M&L for Earthing complete with galvanised steel earth plate electrode of size 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including GI iron wire of size 4 mm dia by means of GI bolts, nuts, check nuts and washers, protected by 15mm bore GI medium grade ISI marked pipe upto and including test points. Earth plate shall be surrounded by alternate layer 15cm thick of charcoal or coke and common salt all around bottom and top , 20mm bore GI medium grade ISI marked pipe for watering and including funnel,wire mesh,PCC chamber pit made with PCC(1:3:6) type C-1(using 20mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50M, pit cover 40mm thick made with RCC(1:2:4) type B-1 (using 20mm graded stone aggregate) including TMT reinforcement 8mm dia@75mm C/C both way,MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm, embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No.3 of SSR 2009(Part-I) and all as directed.Note:- (i) PCC chamber shall be constructed at least 1.5 meter away from the earth electrode and pipe for watering shall be provide in slanting manner.(ii) Protection pipe and earthing lead upto test point from top of the earth plate and further upto the body of electrical equipment shall be included in the unit rate of this item.(iii) Earth testing arrangement should be done by contractor as per direction of Engr-In-Charge. |
| 30 | Supply & Fixing LED complete fitting including batten and T-8 Retro LED polycarbonate 1 x 18 Watt, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 1.0sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications all as directed by Engr -in-Charge:--(a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 10 C to plus 45 C(d) Power factor : Minimum 0.95(e) THD : Max 10% (f) IP rating IP- 20.(g) Aluminium housing & Integrated Electronic driver(h) LED Driver of the make as of the luminire.(j) LED driver should be complete with all protections viz open/short protection, over voltage protection, all as per standard design of manufacture.(k) Surge protection minimum 2.5 KV.(l) CCT 6500K (m) CRI : Morethan 80.(n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily). |
| 31 | Supply & Fixing of LED complete fitting 1 x 10 Watt, appx 2 feet long in extruded aluminium housing with wide range of wattage, environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 1.0sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications all as directed by Engr -in-Charge:-(a) Lumen system efficacy of` luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 10 C to plus 45 C(d) Power factor : Minimum 0.95(e) THD : Max 10% (f) IP rating IP- 20.(g) CCT : 6500K (h) LED Driver of the make as of the luminire.(j) LED driver should be complete with all protections viz open/short protection, over voltage protection, all as per standard design of manufacture.(k) Surge protection minimum 2.5 KV.(l) CRI : morethan 80(m) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily). |
| 32 | Supply & Fixing energy efficient LED security light fitting of 25 W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver including electric connection using 3 core PVC insulated overall sheathed flexible copper cable of 1.5sqmm, complete fitting with all accessories and following specifications all as directed by Engr -in-Charge:-(a) Lumen system efficacy of` luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 10 C to plus 50 C(d) Power factor : Minimum 0.95(e) THD : Max 10% (f) CRI : morethan 80 and CCT : 5700K.(g) IP rating : IP66.(h) IK rating : Minimum IK 07(j) Built in potted LED Driver of the make as of the luminaire.(k) LED driver should be complete with all protections viz open/short protection, over voltage protection, all as per standard design of manufacture.(l) Surge protection 4 KV (inbuilt + extended)(m) Lens - High Efficiency wide angle lens.(n) BIS Approved fixtures and driver.(o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily). |
| 33 | S&F and testing LED decorative light fitting surface/recessed mounted 1x 36 watt 2x2 LED flat panel with driver complete suitable for fixing on roof/ceiling with body robust, corrosion resistant, superior finish and without any cracks of through holes including electric connection with using 2 core flexible conductor cable of size 1.0 sqmm complete with all accessories and following specifications:(a) Lumen system efficacy of` luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 10 C to plus 45 C(d) Power factor : Minimum 0.95(e) THD : Max 10% (f) IP rating IP- 20.(g) CCT : 6500K (h) LED Driver of the make as of the luminire.(j) LED driver should be complete with all protections viz open/short protection, over voltage protection, all as per standard design of manufacture.(k) Surge protection minimum 2.5 KV.(l) CRI : morethan 80(m) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily). |
| 34 | Supply & Fix LED Flood light fitting 50 watt 6500 K natural white , IP>65/66 ,grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories all as specified and directed . |
| 35 | Supply & Fixing energy efficient LED security light fitting of 45 W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver including electric connection using 3 core PVC insulated overall sheathed flexible copper cable of 1.5sqmm, complete fitting with all accessories and following specifications all as directed by Engr -in-Charge:-(a) Lumen system efficacy of` luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 10 C to plus 50 C(d) Power factor : Minimum 0.95(e) THD : Max 10% (f) CRI : morethan 80 and CCT : 5700K.(g) IP rating : IP66.(h) IK rating : Minimum IK 07(j) Built in potted LED Driver of the make as of the luminaire.(k) LED driver should be complete with all protections viz open/short protection, over voltage protection, all as per standard design of manufacture.(l) Surge protection 4 KV (inbuilt + extended)(m) Lens - High Efficiency wide angle lens.(n) BIS Approved fixtures and driver.(o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily). |
| 36 | Note for item No - 12.11 to 12.16 (a) Tenderer shall submit test report of LED light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 03 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following case ;- (i) Manfacturing defects. (ii) Failure due to mechanical and electrical impact. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. |
| 37 | M&L for fixing street light housing bracket, made out of 1.5 mtr long 40 mm dia GI light grade pipe bended to 120 degree angle at half meter from bottom,including two sets of clamps made out of mild steel flat iron of size 40x5mm, MS bolt , nut and washers for fixing of bracket on wall including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of zinc chromate primer complete all as specified. |
| 38 | (Area Drainage)M&L for hume pipe 450 mm dia/bore (NP-2) as in drains laid on cad of PCC haunching completed with CI/RCC manhole cover and earth work etc n.exc 1.50 m depth |
| 39 | (Sewage Disposal)M&L 150mm dia Reinforced concrete pipes, Class NP-2 laid in trenches and jointed with collars complete all as specified & as directed. |
| 40 | M&L Concrete bed to 150mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested with cement concrete ( 1:3:6) type D-2 complete all as specified & as directed. |
| 41 | Supply only WPC. (Integral Water Proofing Compound) |
| 42 | Cutting into existing manhole of brick or RCC for 150 mm dia of pipe and making good after fixing complete. |
| 43 | (External Water Supply ) M&L drilling and tapping cast iron water mains (in position) for branch connection of 50mm bore CI/GI pipe including and provn of suitable size MS clamp with nuts, bolts and washers and welded with one GI socket complete all as specified and directed. |
| 44 | Construction of valve pit of double brick masonary of size 600mmx600mmx600mm (internal dimension) with internal plastering from the top of surface including cover of MS sheet 3.15mm thick and angle iron 40mmx40mmx6mm with hinges and locking arrangement including painting with two coat of synthetic enamelled paint over a coat of red oxide and grouting to PCC 1:2:4 plastering in cement morter 1:3, foundation concrete 1:3:6 including necessary earth work complete all as specified and directed. |
| 45 | (External Electrification)Supply and fixing MCCB 100 Amps 415 Volts 04 Pole 25 KA in sheet metal enclosure of 400X300X300 mm size made out of MS sheet 2.0 mm thick with hinged door and locking arrangements with spray painting inside and outside with two coat of synthetic enemable paint over red oxide primer including fixing the enclosure on angle iron frame of 40X40X5 MM grouted in ground in PCC 1:2:4 using 20 mm graded f(For exsting tapping) Please Enable Macros to View BoQ information |
| 46 | (External Electrification)Supply and fixing MCCB 100 Amps 415 Volts 04 Pole 25 KA in sheet metal enclosure of 400X300X300 mm size made out of MS sheet 2.0 mm thick with hinged door and locking arrangements with spray painting inside and outside with two coat of synthetic enemable paint over red oxide primer including fixing the enclosure on angle iron frame of 40X40X5 MM grouted in ground in PCC 1:2:4 using 20 mm graded f(For exsting tapping) Please Enable Macros to View BoQ information |