| 1 | Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in 91 DELHI SCHEDULE OF RATES (E&M)-2025 meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232. c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided. d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices. e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other 92 DELHI SCHEDULE OF RATES (E&M)-2025 accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc. f) Lightning, surge voltage protection, earthing protection and grid islanding. g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required. h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. |
| 2 | Dismentling of exhisting structures like culverts, bridges, retaining walls and other structure comprising of masonary , cement concrete ,wood work, steel work, includingT&P and scaffolding wherever necessary, sorting the dismentied material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 meters |
| 3 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 4 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 5 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 6 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 10 | Providing 75A brick work in C.M. (1:4) in Superstructure -do- -do- all complete job as per specification and direction of E/I. |
| 11 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 12 | Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surfaceincluding preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as perbuilding specification and direction of E/I. |
| 13 | Supplying MS Angle 50x50x6 for fixing barbed wire and concertina coil |
| 14 | Labour for cutting of M.S. angle iron post to required length, one end splitted as fishtailed in a length of 150mmcomplete as per building specification and direction of E/I. |
| 15 | Drilling 6mm dia hole M.S. angle iron for fixing of staples etc. as per building specification and direction of E/I |
| 16 | Providing one coat of synthetic enamel paint of approved shade and make over steel surface including cleaning thesurface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand paperingincluding cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 17 | Supplying Barbed Wire of 4 point 2 ply 12 SWG, 150 m part |
| 18 | Labour for fitting & fixing barbed wire fencing in six rows horizantal up to a height of 1.85 M and two diagonalsincluding fixing of post in cement concrete at 2.5 M centres including cost of staples (but excluding the cost ofcement concrete angle iron post ,its cutting and making holes,nuts and bolts) all complete as per buildingspecification and direction of E/I. |
| 19 | Providing and fixing Concertina coil fencing with punched tape concertina coil 600 mm dIa 10 metre openable length(total length 90M),having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaDed placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reintorced arbed wire, stud tied with G.l. staples and Gl. clips to retain horizontal, including necessary bolts or GI .barbed wire tied to angle iron, all complete as per direction of Engineer-incharge, with reinforced barbed tape(RBT)/ Sping core (2.5 mm thick) wire of high tensile strength of 165Kg/sq mm with tape (0.52mm thick) and weight 43.478 gm/ metre (cost of M.S. angie, C.C. blocks shall be paid separately). |
| 20 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and |binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/1. TMT fe 500 (onty valid for SAIL & TATA STEEL) |
| 21 | providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusivecarriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal ofrust, placing the rods in position all complete as per building specification and direction of E/I. (a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} |
| 22 | (b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag(RINL)}) |
| 23 | (c) 16mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag(RINL)}) Control Room |
| 24 | Centering and shuttering including strutting,propping,etc. and removal of form for (A)Foundations, footings, bases of columns, etc. for mass concrete |
| 25 | (B)Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 26 | (C)Columns, Pillars, Piers, Abutments, Posts and Struts |
| 27 | Clearing of grass and removal of rubbish inside of mechanical workshop and outside up to a distance of 3m outside the periphery of the area of boundary wall Area= (l)129m x(b) 91m = 11739m2 |
| 28 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 29 | Providing 50mm thick cement concrete flooring (1:2:4) with 20mm to 6mm down stone chips finished with flooring coat of neet cement in panels -do- -do- all complete job as per specification and direction of E/I. |
| 30 | Supplying, fitting and fixing 20 gauge GCI sheet gate fitted on MS angle frame of size 60*60*6mm. including cost of fabrication providing necessary locking arraangment with haskal and dommy duly fixed in PCC (1.2.4)block of required size applying a priming red lead paint over steel work tax all complete as per drawing specification and direction of E/I. |
| 31 | Supplying, Fitting and fixing M.S grill made of 20 x 6mm M.S. flat -do- -do- all complete job as per specification and direction of E/I. |
| 32 | Providing 6mm thick C.P. (1:4) in ceiling with clean coarse sand -do- -do- all complete job as per specification and direction of E/I. |
| 33 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) |
| 34 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 35 | Supply, installation, testing and commissioning of MicroProcessor based conventional 4 Zone Fire Alarm Control Panel having the rating of 24 volt DC power supply, consisting 230 / 24 volt SMPS unit, 2 Nos. of 12 volt 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. |
| 36 | Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. |
| 37 | Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers |
| 38 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall usingfixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. |
| 39 | Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the Departmental Officers |
| 40 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. |
| 41 | Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and redoing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. |
| 42 | Providing installation, testing and commissioning of centrifugal Monoblock pump set conforming to IS 9079, 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller,priming funnel ,cock , suitable flanges at suction and delivery side.Pump shall have common shaft for pump and motor . Motor shall besuitable for working on 415 V -+ 10% , 3Ph 50 Hz A.C . Supply. Motor shall be TEFC type and pump set shall be suitable for working at various discharge and head requirements as per scope of work Pump shall be erected on C.C. foundation / cross channels/ RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification , scope of work and direction of Engineer in-charge of following power rating. Suitable for prescribed duty conditions mentioned in TD. 2.2 KW (3.0 HP) |
| 43 | Hire charge for hydrollic truck crane (30T) For shifting heavy machinery within mechanical work shop. |
| 44 | Hire charge for Loder For loading unlosding machinery within mechanical work shop. |
| 45 | Cost of drilling 200mm x 165mm x 125m deep bore well in all kindsof soil and rock in rural area dor installationof pump set with hydraulic DTH rig machine, all complete inciuding supplying all material tools drilling rig and air compressor and equipments as well as fuel lubricants and cost of transporation of rig machine and other vechiles upto the site (basic rates) ---- from 0 to 50 metres |
| 46 | from51 to 165 metres |
| 47 | Supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6 mm wall thickness including welding charges, cost of pipe etc. all complete job |
| 48 | Supplying labour cement and calcium chloride or bentonite solution and equipments for Grouting to Casing Pipe all complete job including carriage of material to work site as per specification & direction of E/ |
| 49 | Supplying all tools, equipments and labour and doing washing 1042( sl. flushing, and developing of drilled tube well to give clean and clear water all complete job as per direction of E/. |
| 50 | Supply & Fixing of Star Delta Starter 415V, Three phase, 50Hz. With Senciouser comprising of contactor with bi-metalic relay with necessary push button etc.(12.5 to 15 HP) |
| 51 | 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable. Supplying flat flexible submersible cable with copper conductor,PVC insulated, and PVC sheathed 3 core 4sq.mm |
| 52 | Supplying submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery headand discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V+10%, 3PH, 50 HzA.C. supply with cable guard, thrust carbon/ fiber bearing to withstandentire hydraulic thrust, water proof winding shall be provided. The Pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copperconductor cable in single/double run shall be provided with each pump.(3 HP) |
| 53 | Supply of premium make cpvc pipe of 54mm od pipe |
| 54 | Supplying all tools, equipment and labour and lowering 32 mm dia medium quality G.I Pipe in drilled tube well in 3 mtrs. length . all complete job as per direction of E/I including carriage of materials (Basic rate). |
| 55 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 56 | Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow of all tanks capacity 5000.00 litres Capacity Water storage Tank. |
| 57 | (VII)65mm |
| 58 | (VI)50mm |
| 59 | G.I fitting(conforming to IS-1879) (E)GI plan socket (VII)65mm |
| 60 | (VI)50mm |
| 61 | Poviding and supplying in standard length high density poly ethelene pipe (HDPE pipe ) conforming to IS 4984/14151/12786/13488 (latest rivision with necessary joininting mateials like mechnical conectorer i.e thread/insert joint / quick release coppelar joint /compression fitting joint or flenge joints exculding couplor/ specials and taxes) Note: the rates are F.O.R at work sight in jharkhand including royality ,inspection charge and other taxes but excluding GST and CP HDPE pipe of materials grade PE80-PN06(dia in 63mm) |
| 62 | Poviding and supplying in standard length high density poly ethelene pipe (HDPE pipe ) conforming to IS 4984/14151/12786/13488 (latest rivision with necessary joininting mateials like mechnical conectorer i.e thread/insert joint / quick release coppelar joint /compression fitting joint or flenge joints exculding couplor/ specials and taxes) Note: the rates are F.O.R at work sight in jharkhand including royality ,inspection charge and other taxes but excluding GST and CP HDPE pipe of materials grade PE80-PN06(dia in 50mm) |
| 63 | GM ull way valve (ISI marked ) (i) 50mm dia wt not less than 1.4kg without wheel |
| 64 | Carriage of materials. (i) Sand -14km (p) + 1km(k) |
| 65 | (ii) Cement -35km (p) + 0km(k) |
| 66 | (iii) Stone Chips -12km (p) + 2km(k) |
| 67 | (iv) Bricks -5km (p) + 3km(k) |
| 68 | (V)Steel -35km (p) + 0km(k) |
| 69 | MAINTENANCE FOR 5 YEARS |
| 70 | Add GST @18% |
| 71 | Add Labour Cess @1% Please Enable Macros to View BoQ information |