Bids Are Invited For Custom Bid For Services - Hiring Of Services For Fitness For Service And Remaining Life Assesment (As Per Api 579-1:2007) Of Static Equipments And Piping At Hazira Compressor Station - Ffs Level 1 & 2 , Heat Exchangers , Pressure, Hazira-Gujarat
TDR : 55488963
Tender Notice
BOQ
20 Days Left
Hazira
Gujarat
Bids Are invited for Custom Bid For Services - Hiring Of Services For Fitness For Service And Remaining Life Assesment (As Per Api 579-1:2007) Of Static Equipments And Piping At Hazira Compressor Station - Ffs Level 1 & 2 , Heat Exchangers , Pressure
PIPING SYSTEM PIPING SYSTEM (2\\"-30\\")PIPING SYSTEM. PIPE DIA: 2-30\\", ABOVE GROUND, PIPING CLASS: D1A/ A1A/ A1K & B1K, BASIC MATERIAL: API 5L GR. B/ X52/ X60/ X65/ X70, API 5L GR. B.Pipings of various sizes i.e. from 2\\" to 30\\" are installed at Hazira Compressor Station. Most of the pipes are above ground & non-insulated.
PIPING SYSTEM PIPING SYSTEM (2\\"-30\\")PIPING SYSTEM. PIPE DIA: 2-30\\", ABOVE GROUND, PIPING CLASS: D1A/ A1A/ A1K & B1K, BASIC MATERIAL: API 5L GR. B/ X52/ X60/ X65/ X70, API 5L GR. B.Pipings of various sizes i.e. from 2\\" to 30\\" are installed at Hazira Compressor Station. Most of the pipes are above ground & non-insulated.
6
FFS LEVEL 1 & 2
FFS LEVEL 1 & 2
7
LEVEL 3 ASSESSMENT BASED ON THE RESULT OF LEVEL 1 & 2 ASSESSMENT AND SITE CONDITION. -The assessment procedures included in this level are intended to provide the most detailed evaluation which produces results that are more precise than those from a Level 2 assessment. In a Level 3 Assessment the most detailed inspection and component information is typically required, and the recommended analysis is based on numerical techniques such as the Finite Element Analysis method. Level -3 assessment (FEA Analysis) shall be done based upon the outcome of the first two levels of study-if required.
LEVEL 3 ASSESSMENT BASED ON THE RESULT OF LEVEL 1 & 2 ASSESSMENT AND SITE CONDITION. -The assessment procedures included in this level are intended to provide the most detailed evaluation which produces results that are more precise than those from a Level 2 assessment. In a Level 3 Assessment the most detailed inspection and component information is typically required, and the recommended analysis is based on numerical techniques such as the Finite Element Analysis method. Level -3 assessment (FEA Analysis) shall be done based upon the outcome of the first two levels of study-if required.
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.