Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Appendix A : Kavarathode Ganga SWSS |
| 2 | 1.OVER HEAD RESERVOIR & PUMP HOUSE RENOVATIONWashing OHSR/GLSR using brooms, brushes and bleaching powder by engaging coolies, scrubbing twice, washing and cleaning using fresh water, including side wall, floor slab and columns, disposing the the slurry / waste materials away from the immediate premises and within the initial lead of 50m from the periphery of the tank, without causing any damage to the existing structure and installations, charges including the operation of valves, conveyance and hire charges of tools and as per the direction of the department officers etc. complete. |
| 3 | Boring RCC slab above 12cm and up to 15cm thick for providing pipes or fittings of size 80mm to 100mm and rectifying slab with cement concrete 1:2:4 using 20mm broken stone and finishing the top and bottom with cement mortar after placing the pipe or fittings. |
| 4 | Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia |
| 5 | Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Providing and applying Dr.Fixit, classic Damp Guard, of Pedilite brand/ Araldite Builder Barrierkot Epoxy / Nitocote EP405 water proof coating for waterproofing treatment to the RCC structures like retaining walls, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels, / subway and bridge deck etc., prepared by mixing the 1 Part Base & 1 Part Hardener and one part water and applying the same on the internal plastered surface, 2 coats, with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048and resistant to 16 bar hydrostatic pressure on negative side. The work shall be carried out all completeas per specification and the direction of the engineer in-Charge. The product performance shall carryguarantee for 10 years against any leakage |
| 7 | Providing and fixing G.I. pipes(Medium) complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall40 mm dia nominal bore |
| 8 | Providing and fixing G.I. pipes(Medium) complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore |
| 9 | Providing and fixing G.I. pipes(Medium) complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall50 mm dia nominal bore |
| 10 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 11 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 12 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 13 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 14 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 15 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 16 | 2.HOUSE CONNECTIONProviding and fixing 15mm water meter from existing PVC/HDPE line using 20mm Indian Standard Class 6 uPVC pipe of average length upto 5m and 20mm 12.5kg/cm2 uPVC Ball Valve, Elbows, MTAs, FTAs, couplers, PVC Service Saddles of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, stand post with 63 mm 4kg/cm2 pvc pipe height of 1.3 mtr (1m above ground level and 0.3m below ground level) with end cap at top, providing 15mm pvc tap in the water meter assembly for 15mm water connection, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. |
| 17 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 19 | Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers |
| 20 | 3.WATER SAMPLE TESTTesting water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters. |
| 21 | 4.PUMP SET FOR OPEN WELL & PUMP HOUSEa) Pump & Motor: Supply, erection, testing and commissioning of KWA prequalified reputed make open well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter and BEE 3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl/ Diffuser with ISI mark. The pump shall be directly coupled to a continious rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283/ 1995 as amended thereafter, siutable for operation in AC 3 phase 380 V + /- 10%, 50 Hz + /- 5%,Duty Conditions :Discharge -1.93 lpsTotal Head -31 mSuction Head - 10 mLength of suction Pipe - 10 mb) Starter:Supply and delivery of Direct On Line starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitorc) Panel board:Supply, erection, testing and commissioning of one number open board - single sheet type control panel board, suitable for providing control system for running motor pump set, suitable capacity Main Switch, DOL starter supplied, provided with a common earth for the entire panel as per IE rules and code of practice. The panel shall be fitted on the Wall or seperate MS Support to prevent any wetness, moisture, allowing sufficient free space for wiring, air circulation in back side of board with proper support on wall or support, including necessary plastering patch works, concrete worksd) Cabling work:Supply, laying, testing and commissioning Flat submersible Copper Cable not below 2.5 sqmm for wiring between Main switch, Starter, Motor pump set considering energy conservation, including additional length allowance as loop for future repaire as per the direction of Engineer.e) Earthing:Supply of all materials and providing suitable earthing by using suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.f) Capacitor:Supply, erection, testing and commissioning of heavy duty APF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834g) Valves:Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non retum valve of 50 mm or dia of pumping line 1.60 PN pressure rating. Fitting of valves shall include proper RCC support for Non return valves and Sluice Valves of reputed make.h) Pressure Gauge:Supply of suitable size best quality heavy duty ISI marked Pressure Gauge with controll Valvei) Suction and delivery pipe connections:Supply and fitting of dia. not below 50 mm dia. according to pump discharge, best quality C class GI erection pipe for a total length of 10 m suitable for the above pump set with suitable long coupling, bends, Flanges, nut and bolts IR sheet packing etc. complete (erection pipe shuould be of 3 m each with suitable coupling / flanged joints to withstand the heavy load and for facilitating lifting and erection of motor) and connecting the delivery side of the pump with the valves and suitable specials, including cutting, welding, jointing to link the line with existing pumping main near well.j) General Conditions:Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and acessories supplied. |
| 22 | Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes. 2.50 sq.mm. |
| 23 | Supply of uPVC Pipe, 10kg/cm2, 25mm Dia.as per IS 4985 :2000 |
| 24 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 25 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 25 mm nominal outside diameter pipes. |
| 26 | Supplying and laying UPVC pipe specials for 25mm dia UPVC pipe with class 10kg/cm2 or higher at 3% rate of cost of pipe |
| 27 | Supply and errect ready made ferrocement pump house of size 1.5x1.5x2.1m with following specificationRCC post shall be fixed in PCC 1:3:6 of size 45x45x45cm, foundation alround with solid block masonry with CM 1:6bof 30x40cm size ferrocement wall of 1.5mx2.1m of thickness 25mm ferrocement traingular type roof made of ferrocement slab of thickness 25mm, MS door of size 75x210cm with 1mm thick MS sheet and suitable GI frames and painting with two coats of synthetic enamel paint over a coat of iron primer with suitable locking arrangement and a pad lock of 5 lever , MS ventilator of size 60x40cm, flooring with cc 1:3:6 75mm thick and plastered over 12mm thick cement plaster 1:4 and neat cement flushing coat and all wall surfaces and roof shall be painted with two coats of exterior emulsion paint over coat of primer |
| 28 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 29 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 30 | Lettering with black Japan pint of approved brand and manufacture |
| 31 | 4.PUMPING MAIN FOR OPEN WELLExcavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 32 | Supply of uPVC Pipe, 10kg/cm2, 63mm Dia as per IS 4985 :2000 |
| 33 | Providing and fixing G.I. pipes (Medium) complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore |
| 34 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 35 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes. |
| 36 | Supplying and laying UPVC pipe specials for 63mm dia UPVC pipe with class 10kg/cm2 or higher at 3% rate of cost of pipe |
| 37 | Appendix B : Jyothi Nanniyode WSS |
| 38 | 1.RESERVOIRWashing OHSR/GLSR using brooms, brushes and bleaching powder by engaging coolies, scrubbing twice, washing and cleaning using fresh water, including side wall, floor slab and columns, disposing the the slurry / waste materials away from the immediate premises and within the initial lead of 50m from the periphery of the tank, without causing any damage to the existing structure and installations, charges including the operation of valves, conveyance and hire charges of tools and as per the direction of the department officers etc. complete. |
| 39 | Providing and applying Dr.Fixit, classic Damp Guard, of Pedilite brand/ Araldite Builder Barrierkot Epoxy / Nitocote EP405 water proof coating for waterproofing treatment to the RCC structures like retaining walls, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels, / subway and bridge deck etc., prepared by mixing the 1 Part Base & 1 Part Hardener and one part water and applying the same on the internal plastered surface, 2 coats, with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048and resistant to 16 bar hydrostatic pressure on negative side. The work shall be carried out all completeas per specification and the direction of the engineer in-Charge. The product performance shall carryguarantee for 10 years against any leakage |
| 40 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 41 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 42 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 43 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces |
| 44 | Lettering with black Japan pint of approved brand and manufacture |
| 45 | 2.PUMP HOUSE AND DISTRIBUTIONSupply of uPVC Pipe, 10kg/cm2, 40mm Dia. as per IS 4985 :2000 |
| 46 | Supply of uPVC Pipe, 10kg/cm2, 50mm Dia.as per IS 4985 :2000 |
| 47 | Supply of uPVC Pipe, 10kg/cm2, 63mm Dia.as per IS 4985 :2000 |
| 48 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 49 | Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. |
| 50 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 or leaner mix ( including equivalent design mix) |
| 51 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 40 mm nominal outside diameter pipes. |
| 52 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 50 mm nominal outside diameter pipes. |
| 53 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes. |
| 54 | Supplying and laying UPVC pipe specials for 40mm dia UPVC pipe with class 10kg/cm2 or higher at 3% rate of cost of pipe |
| 55 | Supplying and laying UPVC pipe specials for 50mm dia UPVC pipe with class 10kg/cm2 or higher at 3% rate of cost of pipe |
| 56 | Supplying and laying UPVC pipe specials for 63mm dia UPVC pipe with class 10kg/cm2 or higher at 3% rate of cost of pipe |
| 57 | Engaging Coolie. |
| 58 | Engaging Fitter ( grade 1). |
| 59 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 60 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 61 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 62 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 63 | Providing and fixing G.I. pipes(Medium) complete with G.I fittings including trenching and refilling etc. External work40 mm dia nominal bore |
| 64 | Providing and fixing G.I. pipes (Medium) complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore |
| 65 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall50 mm dia nominal bore |
| 66 | Boring RCC slab above 12cm and up to 15cm thick for providing pipes or fittings of size 80mm to 100mm and rectifying slab with cement concrete 1:2:4 using 20mm broken stone and finishing the top and bottom with cement mortar after placing the pipe or fittings. |
| 67 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 68 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 69 | :Providing and fixing 15mm water meter from existing PVC/HDPE line using 20mm Indian Standard Class 6 uPVC pipe of average length upto 5m and 20mm 12.5kg/cm2 uPVC Ball Valve, Elbows, MTAs, FTAs, couplers, PVC Service Saddles of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, stand post with 63 mm 4kg/cm2 pvc pipe height of 1.3 mtr (1m above ground level and 0.3m below ground level) with end cap at top, providing 15mm pvc tap in the water meter assembly for 15mm water connection, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. |
| 70 | Providing 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. |
| 71 | Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads, and excluding cost of materials etc., and as per the directions of the department officers. |
| 72 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 73 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 74 | Lettering with black Japan pint of approved brand and manufacture |
| 75 | 3.OPEN WELLDismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 76 | 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 77 | White washing with lime to give an even shade:New work (three or more coats) |
| 78 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 79 | Constructing boundary wall with precast concrete sheets ( Sneha mathil ) having minimum thickness 2.5cm, casted with suitable reinforcement arrangements. Concrete pillars of size 15X15 cm with suitable groove arrangements to install concrete sheets at 1.5m intervals should be provided with base fixed in concrete. Entire wall system should be steady and aesthetical appearing. All cost of materials, labour, fixing charges, curing charges, tools, plants, conveyance etc. included. |
| 80 | Supply and fixing weld mesh 50 mm x 50mm , 10 gauge |
| 81 | Supply and fixing chicken mesh 24 gauge |
| 82 | a) Pump & Motor: Supply, erection, testing and commissioning of KWA prequalified reputed make open well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter and BEE 3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl/ Diffuser with ISI mark. The pump shall be directly coupled to a continious rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283/ 1995 as amended thereafter, siutable for operation in AC 3 phase 380 V + /- 10%, 50 Hz + /- 5%,Duty Conditions :Discharge -1.96 lpsTotal Head -31 mSuction Head - 10 mLength of suction Pipe - 30 mb) Starter:Supply and delivery of Direct On Line starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitorc) Panel board:Supply, erection, testing and commissioning of one number open board - single sheet type control panel board, suitable for providing control system for running motor pump set, suitable capacity Main Switch, DOL starter supplied, provided with a common earth for the entire panel as per IE rules and code of practice. The panel shall be fitted on the Wall or seperate MS Support to prevent any wetness, moisture, allowing sufficient free space for wiring, air circulation in back side of board with proper support on wall or support, including necessary plastering patch works, concrete worksd) Cabling work:Supply, laying, testing and commissioning Flat submersible Copper Cable not below 2.5 sqmm for wiring between Main switch, Starter, Motor pump set considering energy conservation, including additional length allowance as loop for future repaire as per the direction of Engineer.e) Earthing:Supply of all materials and providing suitable earthing by using suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.f) Capacitor:Supply, erection, testing and commissioning of heavy duty APF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834g) Valves:Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non retum valve of 50 mm or dia of pumping line 1.60 PN pressure rating. Fitting of valves shall include proper RCC support for Non return valves and Sluice Valves of reputed make.h) Pressure Gauge:Supply of suitable size best quality heavy duty ISI marked Pressure Gauge with controll Valvei) Suction and delivery pipe connections:Supply and fitting of dia. not below 50 mm dia. according to pump discharge, best quality C class GI erection pipe for a total length of 10 m suitable for the above pump set with suitable long coupling, bends, Flanges, nut and bolts IR sheet packing etc. complete (erection pipe shuould be of 3 m each with suitable coupling / flanged joints to withstand the heavy load and for facilitating lifting and erection of motor) and connecting the delivery side of the pump with the valves and suitable specials, including cutting, welding, jointing to link the line with existing pumping main near well.j) General Conditions:Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and acessories supplied. |
| 83 | 4.WATER QUALITY TEST FOR OPEN & BORE WELLSTesting water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters. |
| 84 | 5.PUMPSET FOR BORE WELLCharges for removing all electrical & pipe connection from the starter to the motor and liftting the motor pumpset from the well with the help of tripode and chain block and dismantaling the 3inch gi pipe one by one and safely landed the motor pumpset and conveying the motor pump set from the pump house to near road side and loaded to the vechile and safely convenced to the work shop . including cost of all material , labour and hire charges for tools etc complete. |
| 85 | a) Pump & Motor:Supply, erection, testing and commissioning of KWA pre-qualified reputed make Bore well submersible motor pump set suitable to 150mm dia bore, coforming to IS 8034/2002 and amended thereafter and BEE 3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl / Diffuser with ISI mark. The pump shall be directly coupled to a continious rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283,/ 1995 as amended thereafter, siutable for operation in AC 3 phase 380 V + /- 10%, 50 Hz + / - 5%,Duty Conditions :Discharge -1.24 lpsTotal Head -139 mSuction Head - Nil mLength of suction Pipe - 810 mb) Starter:Supply and delivery of Direct On Line starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitorc) Panel board:Supply, erection, testing and commissioning of one number open board - single sheet type control panel board, suitable for providing control system for running motor pump set, suitable capacity Main Switch, DOL starter supplied provided with a common earth for the entire panel as per IE rules and code of practice. The panel shall be fitted on the Wall or seperate MS Support to prevent any wetness, moisture, allowing sufficient free space for wiring, air circulation in back side of board with proper support on wall or support, including necessary plastering patch works, concrete worksd) Cabling work:Supply, laying, testing and commissioning Flat submersible Copper Cable not below 4 sqmm for wiring between Main switch, Starter, Motor pump set considering energy conservation including additional length allowance as loop for future repaire as per the direction of Engineer.e) Earthing:Supply of all materials and providing suitable earthing by using suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.f) Capacitor:Supply, erection, testing and commissioning of heavy duty APF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834g) Valves:Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non retum valve of 50 mm dia. 1.60 PN pressure rating. Fitting of valves shall include proper RCC support for Non return valves and Sluice Valves of reputed make.h) Pressure Gauge :Supply of suitable size best quality heavy duty ISI marked Pressure Gauge with controll Valvesi) Suction and delivery pipe connections:Supply and fitting of dia. not below 50 mm dia. according to pump discharge, best quality C class GI erection pipe, for a total length of 10 m suitable for the above pump set with suitable long coupling, bends, Flanges, nut and bolts IR sheet packing etc. complete (erection pipe shuould be of 3 m each with suitable coupling / flanged joints, to withstand the heavy load, and for facilitating lifting and erection of motor) and connecting the delivery side of the pump with the valves and suitable specials including cutting, welding, jointing to link the line with existing pumping main near well to connect with the pumping main.j) General Conditions:Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and acessories supplied. |
| 86 | Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes. 4 sq.mm. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy