Water Resources and Irrigation Government Departments Closing in 6 days TDR #55488707

Tender For Sustainability Support To Community Management Water Supply Schemes: 2025-26 - Onthammal Wss, Keeryagadi Palorakunnu Wss, Madolathilkkunnu Wss, Theyythamkattil Water Supply Scheme And Aroramala Water Supply Scheme In Ayanchery Gramapanchay

Issued by Government Departments · Kozhikode, Kerala
Tender Value
13.62 Lakhs
Estimated cost
Bid Submission
08 Jul 2026
6 days left
EMD
34100
Bank guarantee accepted
Document Fee
3267
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kozhikode → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Sustainability Support To Community Management Water Supply Schemes: 2025-26 - Onthammal Wss, Keeryagadi Palorakunnu Wss, Madolathilkkunnu Wss, Theyythamkattil Water Supply Scheme And Aroramala Water Supply Scheme In Ayanchery Gramapanchayath - Kozhikode District

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 29-May-2026 Corrigendum for time extension 2 Date 08-Jun-2026
2 22-May-2026 Corrigendum for time extension 1 Date 29-May-2026
3 08-Jun-2026 Corrigendum for time extension 3 Date 15-Jun-2026
4 29-May-2026 Corrigendum for time extension 2 Date 08-Jun-2026
5 22-May-2026 Corrigendum for time extension 1 Date 29-May-2026
6 22-May-2026 Corrigendum for time extension 1 Date 29-May-2026
7 29-May-2026 Corrigendum for time extension 2 Date 08-Jun-2026
8 22-May-2026 Corrigendum for time extension 1 Date 29-May-2026
9 08-Jun-2026 Corrigendum for time extension 3 Date 15-Jun-2026
10 16-Jun-2026 CORRIGENDUM FOR TIME EXTENTION Date 26-Jun-2026
11 27-Jun-2026 Time Extension Date 08-Jul-2026
12 16-Jun-2026 CORRIGENDUM FOR TIME EXTENTION Date 26-Jun-2026
13 08-Jun-2026 Corrigendum for time extension 3 Date 15-Jun-2026
14 22-May-2026 Corrigendum for time extension 1 Date 29-May-2026

BOQ

Name of Work:- Sustainability Support to Community Management Water Supply Schemes: 2025-26 - Onthammal WSS, Keeryagadi Palorakunnu WSS, Madolathilkkunnu WSS, Theyythamkattil WSS and Aroramala WSS in Ayanchery Gramapanchayath - Kozhikode District
Sl. No. Item Description
1Appendix A :Onthammal WSS
2Pump HouseClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
3Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
4Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
5Lettering with black Japan pint of approved brand and manufacture
6Tank Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
7Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
8Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
9Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
10Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
11Welding by gas or electric plant including transportation of plant at site etc. complete.
12WELLRemoving white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
13Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
14Desilting open wells of dia above 3.5m and up to 6.0m and depth up to 7.5m by earth work excavation in or under water, after closing the inlet valves and plugging any holes in the steining by engaging divers with breathing accessories, bailing out water using pump set of suitable capacity, lifting the excavated silt/mud/clay using ropes, pulleys and buckets and disposing the same within minimum lead of 50 m from the periphery of the well, including engaging coolies for scrapping the inner side of the well, without causing any damages to the existing structures and installations, including hire and conveyance of tools and plant and as per the directions of the department officers etc. complete.
15Water Tank Manhole cover Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
16Pipe Line Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
17Engaging Coolie.
18Engaging Fitter ( grade 1).
19Chlorine dozer Supply installation and commissioning of 1 number of chlorine dosing system with all necessary accessories based on the site conditions and as directed by the Engineer in charge. The chlorine solution shall be directly injected to the system at suitable point by using suitable chemical dosing pump (solenoid dosing metering pump)having adjestable discharge of 5liters/hour at a delivery pressure of 10kg/cm2 so as to maintain required residual chlorine in the treated water as per the norms including best quality tank(capacity not less than 50liter) with top cover and all other accessories and wiring from existing panel board to the pump set by using power cables encased in PVC conduit and trial running etc.
20Water Quality TestingTesting water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters.
21Appendix B :Keeryangadi Palorakunnu WSS
22Clearing Jungle in the site, Head leading of Laterite to the site Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
23Engaging Coolie.
24Construction of new compound wall Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two levelincluding all cost of materials, labour charges etc
2512 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
26Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
27Pipe Line- additional length Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
28Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
29Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
30Supply of PVC Pipe, 10kg/cm2, 40mm Dia
31Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of50m, in all kinds of soil.
32Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 40 mm nominal outsidediameter pipes.
33Engaging Fitter ( grade 1).
34Engaging Coolie.
35Supply and laying UPVC pipe specials for 40mm dia UPVC pipe with class 10kg/cm2 or higher @ 3% of cost of pipe
36Pump Set Pump & MotorSupply, erection, testing and commissioning of KWA pre-qualified reputed make open well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter and BEE3 Star of rated discharge, and Head, with Bronze or Cast SSimpeller, Brass Screws and CI FG 200 grade Pump Bowl / Diffuser with ISI mark. The pump shall be directly coupled to a continious rated two pole suitable wet typevertical squirrel cage induction motor as per IS 9283,/ 1995 as amended thereafter,siutable for operation in AC 3 phase 415 V + /- 10%, 50 Hz + / - 5%,Duty Conditions :Discharge - 2.66 lpsTotal Head - 102 mStarterFully automatic air break star delta starter with single phase preventor with ammeter confirming to IS 13947, iec 60947-1 with auto restart facility for pump houses where panel boards are available, Supply and delivery of Star-Delta starter where panel boards are available confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V(+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 Nos., CT operated Ammeter(65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature Circuit breaker, Thermal Overload relay, AirBreak contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm / 4 sq. mm copper pvc insulated cable, powder coated vermin proof box,including the capacitor. as per IE rules and code of practice, for working 7.5 HP Submersible pump sets at a time , considering all practical losses in Voltage and efficiency.Panel boardSupply, erection, testing and commissioning of one number cubical type floor mounted MS fabricated dust and vermin proof common control panel board , suitable for providing control system for running these two motor pump sets at a time, suitable capacity MCCBs , providing suitable size Aluminium bus bar , provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation, for working 7.5 HP Submersible pump sets at a time.Cabling workSupply, laying, testing and commissioning of 185 sqmm x 3.50 core XLPE cables for the above pump set from panel board to starter and Copper Cable not below 25 sqmm , 6 lines, from starter to motor, for working7.5 HP Submersible pump sets at atime. considering energy conservation, including providing necessary Cable Tray of MS fabrication in side the building and sand filled brick trench, additional length allowance as loop for future repaire as per the direction of Engineer.EarthingSupply of all materials and providing suitable earthing byusing suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.CapacitorSupply, erection, testing and commissioning of heavy dutyAPF capacitor for the motor to get a power factor above 0.95. The capacitor shallconfirm to IS 2834ValvesSupply of suitable size best quality heavy duty ISI marked CIdouble flanged sluice valve and Non retum valve of 150 mm dia. 1.60 PN pressurerating. Fitting of valves shall include proper RCC support , for Non return valves andSluice Valves , of reputed make.Suction and delivery pipe connectionsSupply and fitting of 150mm dia. best quality C class GI erection pipe, for a totallength of 10 m. suitable for the above pump set with suitable flanges, bends, nut andbolts IR sheet packing etc. complete (erection pipe shuould be of 2m each withflanged joints, welded firmly inside and out side for the flange, to hold the heavyload, and for facilitating lifting and erection of motor inside the pump house) andconnecting the delivery side ofthe pump with the valves and suitable specials toconnect with the pumping main.General ConditionsWarranty - 2 years (rate inclusive of 2 year warranty and maintenance during aperiod of 2 years from the date of commissioning), for Motor pump set and acessoriessupplied.Supply and installation of 185 Sq mm XLPE cable of 3.50 core additional cablebeyond the initial supply of 2x10 mSupply and installation of 25 Sq. mm additional cable beyond the initial supply of2x10 mSupply and installation of 150 mm GI pipe of Class C including Fabrication work forconnecting with the existing pumping main beyond the initial supply of 2x10 m
37WATER QUALITY TESTING Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters
38Appendix C :Madolathilkkunnu WSS
39Common work-painting Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
40Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparationof surface, etc. complete.On steel work
41Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
42Lettering with black Japan pint of approved brand and manufacture
43Desilting open wells of dia above 6.0m and up to 9.0m and depth up to 10.5m by earth work excavation in or under water, after closing the inlet valves and plugging any holes in the steining by engaging divers with breathing accessories, bailing out water using pumset of suitable capacity, lifting the excavated silt/mud/clay using ropes, pulleys and buckets and disposing the same within minimum lead of 50 m fromthe periphery of the well, including engaging coolies for scrapping the inner side of the well, without causing any damages to the existing structures and installations,including hire and conveyance of tools and plant and as per the directions of the department officers etc. complete.
44Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead
45Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two levelincluding all cost of materials, labour charges etc.
4612 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
47Reservoir Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
4812 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
49Neat cement punning
50Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
51Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources)
52Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
53Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
54Pipe line Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work40 mm dia nominal bore.(Medium)quality and weight as perIS:1239 part 1
55Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
56Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
57Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of50m, in all kinds of soil
58Supply of PVC Pipe, 10kg/cm2, 32mm Dia
59Supply of PVC Pipe, 10kg/cm2, 110mm Dia.
60Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 32 mm nominal outside diameter pipes
61Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing thepipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outsidediameter pipes.
62Engaging Coolie
63Engaging Fitter ( grade 1)
64Supply and laying UPVC pipe specials for 32mm dia UPVC pipe with class 10kg/cm2 or higher @ 3% of cost of pipe
65Supply and laying UPVC pipe specials for 110 mm dia UPVC pipe with class 10 kg/cm2 or higher @ 3% of cost of pipe
66Water Quality Testing Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters
67Chlorine doser Supply installation and commissioning of 1 number of chlorine dosing system with all necessary accessories based on the site conditions and as directed by the Engineer in charge. The chlorine solution shall be directly injected to the system at suitable point by using suitable chemical dosing pump (solenoid dosing metering pump)having adjestable discharge of 5liters/hour at a delivery pressure of 10kg/cm2 so as to maintain required residual chlorine in the treated water as per the norms including best quality tank(capacity not less than 50liter) with top cover and all other
68House Connection Providing 15mm water meter from existing PVC / HDPE line, using 20mm Indian Standard Class 6 uPVC pipe and Ball Valve, uPVC, 12.5kg/cm2, 20mm ,PVC Air valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
69Appendix D :Theyyathamkattil WSS
70Source Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
71Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc
7212 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
73Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
74Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm
75Desilting open wells of dia above 6.0m and up to 9.0m and depth up to 10.5m by earth work excavation in or under water, after closing the inlet valves and plugging any holes in the steining by engaging divers with breathing accessories, bailing out water using pumset of suitable capacity, lifting the excavated silt/mud/clay using ropes, pulleys and buckets and disposing the same within minimum lead of 50 m fromthe periphery of the well, including engaging coolies for scrapping the inner side of the well, without causing any damages to the existing structures and installations, including hire and conveyance of tools and plant and as per the directions of the partment officers etc. complete.
76Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
77Lettering with black Japan pint of approved brand and manufacture
78Supply of PVC Pipe, 10kg/cm2, 63mm Dia
79Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outsidediameter pipes.
80Engaging Coolie
81Engaging Fitter ( grade 1)
82Reservoir Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
8312 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
84Neat cement punning
85Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
86Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
87Lettering with black Japan pint of approved brand and manufacture
88Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
89Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
90Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
91Pipe LineProviding and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore.(Medium)quality and weight as perIS:1239 part 1
92Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work40 mm dia nominal bore.(Medium)quality and weight as perIS:1239 part 1
93Pump setaPump & Motor\\"Supply, erection, testing and commissioning of KWA pre-qualified reputed make open well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter and BEE 3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl/ Diffuser with ISI mark. The pump shall be directly coupled to a continious rated two pole suitable wet typevertical squirrel cage induction motor as per IS 9283/ 1995 as amended thereafter, siutable for operation in AC 3 phase 380 V + /- 10%, 50 Hz + / - 5%,Duty Conditions :Discharge -2.21 lpsTotal Head - 100 m\\"cStarterSupply and delivery of Direct On Line starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push buttonswitches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitordPanel boardSupply, erection, testing and commissioning of one number open board - single sheet type control panel board, suitable for providing control system for running motor pump set, suitable capacity Main Switch, DOL starter supplied, provided with a common earth for the entire panel as per IE rules and code of practice. The panel shallbe fitted on the Wall or seperate MS Support to prevent any wetness, moisture, allowing sufficient free space for wiring, air circulation in back side of board with proper support on wall or support, including necessary plastering patch works, concrete workseCabling workSupply, laying, testing and commissioning Flat submersible Copper Cable not below 4 sqmm for wiring between Main switch, Starter, Motor pump set considering energy conservation, including additional length allowance as loop for future repaire as per the direction of Engineer.fEarthing\\"Supply of all materials and providing suitable earthing by using suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.\\"gCapacitor\\"Supply, erection, testing and commissioning of heavy duty APF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834\\"hValves\\"Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non retum valve of 50 mm or dia of pumping line 1.60 PN pressure rating.Fitting of valves shall include proper RCC support for Non return valves and Sluice Valves of reputed make. \\"hPressure GaugeSupply of suitable size best quality heavy duty ISI marked Pressure Gauge with controll ValveiSuction and delivery pipe connectionsSupply and fitting of dia. not below 50 mm dia. according to pump discharge, best quality C class GI erection pipe for a total length of 10 m suitable for the above pump set with suitable long coupling, bends, Flanges, nut and bolts IR sheet packing etc. complete (erection pipe shuould be of 3 m each with suitable coupling / flangedjoints to withstand the heavy load and for facilitating lifting and erection of motor) and connecting the delivery side of the pump with the valves and suitable specials, including cutting, welding, jointing to link the line with existing pumping main near well.jGeneral ConditionsWarranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and acessories supplied.2\\"Supply of 4 Sq. mm additional cable beyond the initial supply of 10 m. \\"3\\" 50 mm GI pipe of Class C for connectingwith the existing pumping main beyond 10 m \\"
94Water Quality Testing Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters
95Auto Starter Supply and installation of ROBOTIC CONTROL; SYSTEM mobile starter with all required fittings and features like motor ON/OFF through missed call, motor ON/OFF through SMS , in bulid preventer and auto starter suitable every single / three phase motor starter, inbuilt star delta timer , cyclic timer, dry run prevention, over load prevention,real time clock , 1 year guarantee and customer service at site whwnever required
96Appendix E :Aroramala WSS
97Filter Tank Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
98Washing OHSR/GLSR using brooms, brushes and bleaching powder by engaging coolies, scrubbing twice, washing and cleaning using fresh water, including side wall, floor slab and columns, disposing the the slurry / waste materials away from the immediate premises and within the initial lead of 50m from the periphery of the tank, without causing any damage to the existing structure and installations, charges including the operation of valves, conveyance and hire charges of tools and as per the direction of the department officers etc. complete.
99Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
100Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm
101Desilting open wells of dia above 3.5m and up to 6.0m and depth up to 6.0m by earth work excavation in or under water, after closing the inlet valves and plugging any holes in the staining by engaging divers with breathing accessories, bailing out water using pump set of suitable capacity, lifting the excavated silt/mud/clay using ropes, pulleys and buckets and disposing the same within minimum lead of 50 m from the periphery of the well, including engaging coolies for scrapping the inner side of the well, without causing any damages to the existing structures and installations,including hire and conveyance of tools and plant and as per the directions of the department officers etc. complete.
102Pipe line work Supply of PVC Pipe, 10kg/cm2, 160mm Dia
103Supply of PVC Pipe, 10kg/cm2, 200mm Dia
104Supply of HDPE Pipe PE 100 (IS 4984/1995), 10kg, 90mm Outer Dia
105Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outsidediameter pipes.
106Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 200 mm nominal outside diameter pipes
107Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
108Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
109Engaging Coolie.
110Engaging Fitter ( grade 1).
111Laying HDPE pipes (IS : 4984) on land portion including conveying within initial lead and aligning the pipes, electro-fusion welding using automatic or semi-automatic electrofusion machines, testing the pipeline thus fabricated to suit the hydraulic working pressure and after testing, aligning the pipeline, lowering the pipe in position into the trenches already made, testing the line to suitable pressure with potable water before back filling and levelling the trenches including all labour charge, hire for appliances etc., complete but excluding cost of pipe and fittings: 90mm Nominal Outer Diameter pipes.
112Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :80 mm nominal bore
113Dismantling G.I. pipes ( external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges:15 mm to 40 mm nominal bore
114Supply and laying UPVC pipe specials for 200mm dia UPVC pipe with class 10 kg/cm2 or higher @ 3% of cost of pipe
115Supply and laying UPVC pipe specials for 160mm dia UPVC pipe with class 10 kg/cm2 or higher @ 3% of cost of pipe
116GLSR Tank Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
117Washing OHSR/GLSR using brooms, brushes and bleaching powder by engaging coolies, scrubbing twice, washing and cleaning using fresh water, including side wall, floor slab and columns, disposing the the slurry / waste materials away from the immediate premises and within the initial lead of 50m from the periphery of the tank, without causing any damage to the existing structure and installations, chargesincluding the operation of valves, conveyance and hire charges of tools and as per the direction of the department officers etc. complete.
118Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
119Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
120Lettering with black Japan pint of approved brand and manufacture
121Desilting open wells of dia above 3.5m and up to 6.0m and depth up to 6.0m by earth work excavation in or under water, after closing the inlet valves and plugging any holes in the staining by engaging divers with breathing accessories, bailing out water using pump set of suitable capacity, lifting the excavated silt/mud/clay using ropes, pulleys and buckets and disposing the same within minimum lead of 50 m from the periphery of the well, including engaging coolies for scrapping the inner side of the well, without causing any damages to the existing structures and installations, including hire and conveyance of tools and plant and as per the directions of the department officers etc. complete.
122Filter Media Supplying of 2 to 6 mm and 6 to 12 mm size fine pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc. complete as per CPHEEO specifications.
123Supplying of 12 to 20mm size pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc complete and as per CPHEEO specification.
124Supplying of 20 to 40 mm pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per directions of the department officers etc. complete and as per CPHEEO specification.
125Canal Cleaning Earthwork in open well excavation (in or under water) for wells of diameter above 2.5m and up to 3.50m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking.
126House connection Replacing the chocked / damaged 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing mains, up to a length of 5m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / Brass specials viz. brass ferrule, Elbow, MTA, FTA, couplers etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, safely removing & re-fixing existing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges but excluding cost of water meter and meter box and excluding charges for cutting the concrete / tarred / bituminous roads and as per the directions of the department officers.
127Water Quality Testing Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55488707
AUTHORITY Government Departments
TENDER VALUE 13.62 Lakhs
LAST DATE 08-07-2026
Authority
Authority Name Kerala Rural Water Supply And Sanitation Agency
Work Description Tender for Sustainability Support To Community Management Water Supply Schemes: 2025-26 - Onthammal Wss, Keeryagadi Palorakunnu Wss, Madolathilkkunnu Wss, Theyythamkattil Water Supply Scheme And Aroramala Water Supply Scheme In Ayanchery Gramapanchayath - Kozhikode District
Basic Detail
Tender No KRWSA/MPM/SUS/AYA/25-26/27
Bidding Type Tender
Location
City Kozhikode
State Kerala
Key Dates
Publish Date 27 Jun 2026
Submission Date 08 Jul 2026
Open Date 09 Jul 2026
Finance
Tender Value 13.62 Lakhs
Tender Fee 3267
EMD 34100
Exemption Not Available
Document List
5610d655-0614-4a74-b84b-d53bd871d2ad.html
BOQ_1437800.xls
formatayan.pdf
tenderdocumentaya.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 08, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 29, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 15, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 08, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 29, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 29, 2026
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 08, 2026
18:00 IST

Corrigendum-7 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 29, 2026
18:00 IST

Corrigendum-8 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 15, 2026
18:00 IST

Corrigendum-9 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 26, 2026
18:00 IST

Corrigendum-10 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 08, 2026
18:00 IST

Corrigendum-11 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 6 days
Jun 26, 2026
18:00 IST

Corrigendum-12 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 15, 2026
18:00 IST

Corrigendum-13 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 29, 2026
18:00 IST

Corrigendum-14 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

5610d655-0614-4a74-b84b-d53bd871d2ad.html

xls

BOQ_1437800.xls

pdf

formatayan.pdf

pdf

tenderdocumentaya.pdf

pdf

Tendernotice_1 (10).pdf

TenderDetail
Loading tenders