| 1 | S &F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P.brass / stainless steel screws, all complete as per architectural drawings and the directions of Engr-in-Charge. |
| 2 | Taking down of chowkat or frames including shutter without taking off shutters from the frame area not exceeding 1.5sqm each removing from site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed. |
| 3 | All as per Serial item No. 2.00 here in above but exc 1.5 sqm not exc 4sqm |
| 4 | Taking down of shutters of any description not exceeding 1 sqm each all as specified and as directed. |
| 5 | Taking down of shutters of any description exceeding 1 sqm each and not exceeding 2 sqm each all as specified and as directed. |
| 6 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild steel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated). Note: The unit rate quoted by contractor includes all other connected accessories. |
| 7 | S & F for Aluminium Mortice lock, vertical type of size 75 mm, 4 lever, complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Supply & fixing 5.5 thick sheet glass, ordinary quality in square exc 0.5m in each pane complete all as specified and directed. |
| 9 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm PVC sheet reinforced with mild steel Square tube with singal side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet & fixed in position as per manufacturer's instruction all as specified, as shown on drawing on page No 160 of SSR Part-II 2010 all as specified and directed. |
| 10 | S&F factory made solid panel PVC door wire gauzed shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of stainless steel wire cloth i.e. panel will be of wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly all as directed. |
| 11 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples all as specified and as directed. |
| 12 | Hacking out old broken glasses any thickness, size, quality or description from wooden frames glazed with putty or fixed with bead all as specified and as directed. |
| 13 | All as per Serial item No. 12.00 here in above but from metal frame including punching out or drilling out old glazing pins/spring clips and providing and fixing new all as specified and as directed. |
| 14 | S&F sheet glass ordinary quality 3mm thick with oil putty not exceeding 0.5 sqm in each pane all as specified and as directed. |
| 15 | S&F 4mm thick tinted coloured glass with oil putty in square in not exc 0.5 sq.m in each pane complete all as specified and as directed |
| 16 | S&F butt hinge, medium weight ,cold rolled mild steel 100mm long all as specified and as directed. |
| 17 | S&F butt hinges, medium weight ,cold rolled mild steel 75mm long all as specified and as directed. |
| 18 | S&F aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy 300 mm long and fixed all as specified and as directed. |
| 19 | S&F floor door stopper of aluminium alloy body double and tongue anodised with rubber shoe and fixed of size 150 mm all as specified and as directed. |
| 20 | S&F aluminium anodised barred tower bolt of extruded section 200 mm long and fixed all as specified and as directed. |
| 21 | All as per Serial item No. 20.00 here in above but 150mm long all as directed. |
| 22 | S&F extruded aluminium alloy handle fabricated type anodised 150 mm long. |
| 23 | All as per Serial item No. 22.00 here in above but 100mm long |
| 24 | S&F hasp and staple, safety type aluminium anodised with hinge pin including bolt to hing plate and fixed with screw 125 mm long all as specified and as directed. |
| 25 | Taking out cement plaster, any description , from brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 26 | M&L for rendering 15mm thick in cement mortar (1:6) on surfaces other than fair face of brick work of walls, finished even & smooth without using extra cement, complete all as specified & directed. |
| 27 | M&L for preparation of newly plastered wall surfaces and applying two coats of Oil Bound Distemper over a coat of chalk whiting (preparatory to distemper) applied over 1 to 2mm thick BIRLA/ JK (or equivalent) water-proof wall care putty complete all as specified and directed by Engineer -in-Charge. |
| 28 | M&L for complete removal of existing treatement and preparation of old plastered/concrete surfaces of walls/ roof/ incl necessary scafolding by brooming down, steel wire brushing, scrapping down, smoke soot, moulds,moss& efflorescent salts and applying two coats of Distemper Oil emulsion over and including one coat of alkali resistant primer, complete, all as specified and as directed by engr-in-charge. Note : Primer shall be applied after complete removal to existing treatment from old painted plastered/concrete surface. |
| 29 | M&L for Hardcore of guage exc 63mm but not exc. 100 mm, deposited, spread and levelled in layers not exc. 15cm thick, watered and rolled/rammed to a true surface complete all as specified. |
| 30 | M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in floor 75 mm thick complete all as specified. |
| 31 | M&L for Coloured rubber moulded Chequered cement concrete tiles 300 x 300 x 25mm thick, set, jointed and pointed in grey cement mixed with pigments in floors, over 20mm screed bed in CM 1:6, complete all as specified and directed. |
| 32 | Material and labour for Point wiring with 4.0 sqmm FR PVC insulated and sheathed multi stranded (FRLSH) copper conductor cable drawn in and including rigid PVC casing caping of suitable size with sunk cast iron/pressed steel terminal boxes of adequate size with suitable thickness plastic laminated sheet, cover for one 3 pin socket outlet 15 Amp on independent board including continuous 4.0 sqmm copper conductor cable (FRLSH) (multistranded) PVC insulated and unsheathed Cable as earth wire to common earth dolly, complete all as specified and directed by Engr-in-charge |
| 33 | M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including DLP mini trunking of size 32X12.5mm with all finishing accessories and junction elements etc. in any type wall/ ceiling (fixing on wall through rawl plug & stainless steel screw) plastering and making good disturbed surfaces by cement mortar/ paint to match with the existing complete all as specified & directed.Note : 3 Runs of 4 Sqmm wire & 1 run of DLP trunking shall be measured as one length. |
| 34 | M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including DLP mini trunking of size 32X12.5mm with all finishing accessories and junction elements etc. in any type wall/ ceiling (fixing on wall through rawl plug & stainless steel screw) plastering and making good disturbed surfaces by cement mortar/ paint to match with the existing complete all as specified & directed.Note : 3 Runs of 6 Sqmm wire & 1 run of DLP trunking shall be measured as one length. |
| 35 | S&F sheet metal enclosure for DB’s Vertical-TPN Double Door 4 way, AC, 415 volt, IP 54 on the wall with 250 A Copper Bus Bar with MCCB, 160 A, 4Pole of breaking capacity 25kA as incomer, by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface incl connection of cable, testing checking etc complete all as specified & directed. Note :MCCB and MCB will be measured and paid separately. |
| 36 | S&F MCCB, 4P, 125-160 Amps, 415 Volts 50 HZ, 36 KA, Ics= 100% Icu adjustable overcurrent setting 0.67 - 1x In & adjustable short circuit setting as 6 - 12 x In incl. connection of cable testing, checking etc complete all as specified & directed. Type ‘C’ Characteristic |
| 37 | S&F sheet metal enclosure for DB’s SPN Double Door 8 way, AC, 240 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed. |
| 38 | S&F sheet metal enclosure for DB’s for Plug & Socket, SP, AC, 240 volt with MCB SP 20 A on the wall complete by cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed. |
| 39 | Material and labour for flame proof point wiring on wall and surface wiring on ceiling/ roof with necessary fixing arrangements for one light/fan point controlled by one switch with stranded PVC, FRLS insulated and unsheathed copper stranded conductor of size 1.5 sqmm, 1100 volts grade drawn in and including 14 gauge ERW rigid steel conduit (metallic) not less than 20 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc., including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 sqmm, 1100 volts grade for continuous earthing complete all as directed. |
| 40 | Supply and fix flame proof rotary switch in ML6, 16 amps, single pole, 250 volts and enclosed cast aluminium body with threaded cover with switch operated by a sigle pole knob with double entries suitable for 20 mm dia ERW threaded steel conduit duly approved by CMRI dhanbad and as manufacturers intructions including taking down old flame proof rotary switch with enclosure complete all as directed. |
| 41 | M&L for sub main wiring with 4 run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in PVC Casing caping of suitable size with all finishing accessories and junction elements etc. in any type wall/ ceiling (fixing on wall through rawl plug & stainless steel screw) making good disturbed surfaces by cement mortar/ paint to match with the existing complete all as specified & directed. Note : 5 Runs of 6 Sqmm wire & 1 run of PVC casing caping shall be measured as one length. |
| 42 | M & L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron steel wire 4mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI med grade water pipe, 15 mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate no-3 of SSR part No 1 all as directed. |
| 43 | S&F sheet metal enclosure for DB’s for Plug , Three Phase 5 Pin, AC, 440 volt with MCB SP 63 A on the wall complete by cement plaster in cement mortar (1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed. |
| 44 | Supply & fix of MCBs single pole (SPN) 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards conforming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed. |
| 45 | Supply & fix of MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards conforming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed. |
| 46 | S&F of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 Core all as specified and directed by Engr-in-Charge. |
| 47 | Excavating in trenches manually not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note: During excavation no mechanical excavator is permitted at site, contractor will do the excavation through manually. |
| 48 | Returning, filling in incl spreading, leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed. |
| 49 | Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed. |
| 50 | M&L for Double wall corrugated pipe of size 50/38 mm as per IS: 16205 Part-II-2013 laid in trenches/wall for protection cables complete all as specified and directed. Please Enable Macros to View BoQ information |