| 1 | M&L for cleaning of overhead water tanks of any description and removing all scale, dirt etc from bottom, side and from mouths of circulating pipes etc complete all as specified and as directed for the following capacity of tanks :- Note:- Date of cleaning should be clearly mentioned outside the tank with Synthetic enamel paint and Register shall be maintained duly signed by all concerned. |
| 2 | (a) Capacity of the tank exc 250 & n exc 500 Ltrs |
| 3 | (b) Capacity of the tank exc 500 & n exc 1000 Ltrs |
| 4 | (c) Capacity of the tank exc 1000 & n exc 2000 Ltrs |
| 5 | (d) Capacity of the tank exc 2000 & n exc 5000 Ltrs |
| 6 | S&F 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed ( Minimum weight 15 mm- 142 gms / 20 mm -210 gms / 25 mm- 455 gms/ 40 mm -690 gms complete all as specified and as directed |
| 7 | S&F 25 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed ( Minimum weight 15 mm- 142 gms / 20 mm -210 gms / 25 mm- 455 gms/ 40 mm -690 gms complete all as specified and as directed |
| 8 | Dismantling Unsv water storage tanks 500 ltr capacity and removing to store complete all as specified and as directed |
| 9 | Dismantling Unsv water storage tanks 1000 ltr capacity and removing to store complete all as specified and as directed |
| 10 | Dismantling Unsv water storage tanks 2000 ltr capacity and removing to store complete all as specified and as directed |
| 11 | Supply and fixing 500 liters rotational moulded polyethylene water storage tank, multi layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I complete all as specified and as directed. |
| 12 | Supply and fixing 1000 liters rotational moulded polyethylene water storage tank, triple layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I complete all as specified and as directed. |
| 13 | Supply and fixing 2000 liters rotational moulded polyethylene water storage tank, triple layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I complete all as specified and as directed. |
| 14 | Taking up or down steel tubing and connections of 15mm bore, fixed in walls, ceiling, floors, trenches etc complete all as specified and as directed. |
| 15 | Taking up or down steel tubing and connections of 20mm bore, fixed in walls, ceiling, floors, trenches etc complete all as specified and as directed. |
| 16 | Taking up or down steel tubing and connections of 25mm bore, fixed in walls, ceiling, floors, trenches etc complete all as specified and as directed. |
| 17 | S&F 15mm bore GI tubing medium grade with all fittings fixed to wall, ceiling or laid in floors complete all as specified. |
| 18 | S&F 20 mm bore GI tubing medium grade with all fittings fixed to wall, ceiling or laid in floors complete all as specified. |
| 19 | S&F 25 mm bore GI tubing medium grade with all fittings fixed to wall, ceiling or laid in floors complete all as specified. |
| 20 | S&F 20mm Gun-metal. globe or gate valves, with iron wheel headt screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 21 | S&F 25mm Gun-metal. globe or gate valves, with iron wheel headt screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 22 | Demolition of brick work/ block masonry or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material complete all as specified and as directed. |
| 23 | M&L for brick work with sub class B bricks, straight or curved on plan exc 6 M mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 24 | M&L for brick work with subclass B brick, straight or curved on plan exc 6 M mean radius, half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 25 | Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 26 | M&L for 15mm thick rendering with cement mortar (1:4) on fair faces of brick work in two layers (10mm & 5mm) seperately mixed with water proofing compound in top layer as per manufacturer's instructions and finishing the surface even and fair without using extra cement complete all as specified and as directed.Note:- WPC shall be measured and paid seperately under appropiate item. |
| 27 | Supply only liquid WPC (best quality) of approved make |
| 28 | M&L for preparation of new plastered surface of wall & applying two coats of cement base paint over a coat of cement primer all as specified and directed. |
| 29 | M&L for complete removal of existing treatement on plastered or unplastered surfaces of walls including brooming down or steel wire brushing, scrapping down smoke scoot, mould, moss and efflorescent salt, trading oil and greasy spots and applying one coat of cement base paint over a coat of cement primer complete all as specified. |
| 30 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the permises complete all as specified. |
| 31 | M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6 complete all as specified. |
| 32 | M&L for virified Ceramic tiles 10 mm thick (square/ rectangular) light shade, polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and cement to match complete all as specified and directed |
| 33 | M&L for providing non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exc. 0.18 but not exc. 0.38 Sqm as in floor set and joint in cement slurry, jointed & pointed in white or coloured cement to match the surface of the tile complete all as specified and directed |
| 34 | M&L for rendering 10mm thick on brick or concrete surface in cement mortar 1:3 complete all as specified and directed |
| 35 | M&L for providing glazed ceramic coloured tiles of size 450x300 mm (5 to 7 mm thick) as in vetical surface set in cement slurry jointed & pointed in white or coloured cement to match the surface of tile complete all as specified and directed. |
| 36 | M&L for removal of wild growth /plants / shrubs on external surface of buildings at any height upto roof level including making good the disturbed surface in CM 1:4 with water proofing compound as per manufacturer instructions and as directed. |
| 37 | S&F PVC cover for 500 Ltr PVC water storage tank complete all as specified and directed. |
| 38 | S&F PVC cover for 1000 Ltr PVC water storage tank complete all as specified and directed. |
| 39 | S&F PVC cover for 2000 Ltr PVC water storage tank complete all as specified and directed. |
| 40 | S&F in repair stop valves 15mm dia cast copper alloy screwed down high pressure with crutch of butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 41 | S&F in repair 15mm bib tap cast copper alloy chromium plated with crutch or butterfly handle screwed down for iron pipe or for bass ferrule complete all as specified and directed. |
| 42 | S&F in repairs pillar taps, 15mm dia cast copper Alloy with capstan heads, chromium plated ,screwed down, high pressure, with or with out lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 43 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and as directed. |
| 44 | M&L for providing 75mm thick PCC 1:3:6 type C2 (40mm graded aggregate) as in flooring and paving finishing the surface even and smooth without using extra cement complete all as specified and as directed. |
| 45 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 46 | S&F Mild steel framed work in tubular trusses and tubular posts using ERW or induction butt welded tubes conforming to I.S 1161-1979 Grade St-240 including necessary welding, bolting, special shaped washer, clamps, cleats etc complete all as specified & as directed. |
| 47 | S&F welded steel wire fabric, weight not exc 4 Kg per sqm, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement complete all as specified & as directed. |
| 48 | S&F in repair wire netting of stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples of mesh size 20 mm complete all as specified & as directed. |
| 49 | M&L for preparation of new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete as specified and directed. |
| 50 | Taking down eaves gutter and rain water pipes ( any size or pattern) including all fittings, heads,shoes, bends, swan necks etc including cleaning or refixing or removal to store complete all as specified & directed. |
| 51 | S&F rain water drainage pipes PVC (SWR) pipes single socketed 110mm bore in any length with rubber rings joints fixed to walls complete all as specified & as directed. |
| 52 | S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors 110mm complete all as specified & as directed. |
| 53 | S&F PVC (SWR) bends any radius 110mm bore complete all as specified & as directed. |
| 54 | S&F 75mm bore PVC ( SWR) Pipes single socketed, in any length with rubber ring joints,fixed to wall complete all as specified and directed. |
| 55 | S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 56 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof sutable for 75 / 110 mm dia including drilling holes & fixed to wall with nails etc complete all as specified & as directed. |
| 57 | M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified & as directed. |
| 58 | M&L for rendering 15 mm thick finished even and smooth with WPC as per manufacturer instructions (in two layers-10mm+5mm) over roof slabs for laying water proofing treatment in Cement plaster (1:3) complete all as specified and directed. |
| 59 | M&L for water proofing treatment to flat roof and edges applying 3 mm thick APP based polymeric membrane of approved manufacturer with weight not less than 3.00 kg / sqm reinforced with non woven polyster fabric weight not less than 150 gm per sqm on primed surface by force application over the APP membrane @ 0.11 kg/ sqm over applying evenly a priming coat with bituminous primer @ 10 kg kg/sqm after necessary cleaning the surface and applying one coat of aluminium paint over APP membrane including removal of existing APP membrane complete all as specified and as directed |
| 60 | M&L for Prime the surface with BTD with water @ 1:1 ratio (200gm BTD: 200 gm Water) and use as primer @ 400 gm / m². Allow the primer coat to touch dry condition. Apply 1 st coat of ShaliUrethane® BTD @ 0.8 kg/ m² by brush / roller / airless spray while the primed surface is tacky. For faster and smoother application, apply with airless gun.Allow 1 st coat to dry for 10 - 12 hr. Apply 2nd coat of ShaliUrethane BTD @ 0.8 kg/ m² by brush /roller / airless spray for final DFT of 1200 micron in two coats,including taking down old APP membrane and preparation of surface,Product by STP or equivelant MES approved make complete all as specified and as directed. |
| 61 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as directed. |
| 62 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and as directed. |
| 63 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and as directed. |
| 64 | M&L for cement concrete 1:2:4 type B0 1:2:4 (12.5 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed plates, kerbs not providedfor in Item 04028, water troughs and the like including weathering, slightly roundedor chamfered angles andthroating, as directed |
| 65 | Taking down chowkats or frame exc 1.5 sqm but n exc 4.00 sqm with shutter (with out taking off shutter from frame) all as specified and remooving from site complete all as specified and as directed. |
| 66 | Taking down shutter exc exc.2 sqm all as specified and removing from site complete all as specified and as directed. |
| 67 | S&F and erecting in position in repair steel rolling shutterswith thickness 1.25 mm push or pull or manual type without ball bearing as specified including top cover anchoring rod hasp and staple and one shop coat of primer complete all as specified and directed |
| 68 | S&F in repair lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed. |
| 69 | Taking down and opening the existing steel rolling shutter pull push type not exc 12 sqm each in area as clear opening including hood cover cleaning the guides suspended shaft anti guide channels straightening / rolling shaft and replacement of bolts and nuts after greasing all the moving parts of rolling shutters and refixing in the same opening to make it for smooth functioning complete all as specified and directed |
| 70 | S&F in repair ball bearing for rolling shutter complete all as specified and as directed. Please Enable Macros to View BoQ information |