| 1 | Excavation in trenches not exceeding 1.5m depth and not exc 1.5m wide and getting out in hard / dense soil for laying of pipe lines complete all as specified and directed. |
| 2 | Returning and filling in soil including spreading levelling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 3 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 4 | M&L for cutting /breaking of cement concrete path or bituminous road of any thickness with or without reinforcement for taking up/down of DI/GI/CI pipes and connection and making good to match existing surface by PCC (1:2:4), type B1 (using 20mm graded crushed stone aggregates) complete all as specified as directed. |
| 5 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed. |
| 6 | Dismantling of stone slabs, tiles and paver blocks of any description or thickness, laid dry and pointed in floors, aprons complete all as specified and directed |
| 7 | M&L for providing and laying for cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) as in coping, hold fast or of similar typr of work including necessary form work complete all as specified and as directed. |
| 8 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M - 35 grade with approved colour, design & pattern as in foot path, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator , filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 9 | Taking up Cast iron water main of size 150mm dia including all fittings for spigot and socket ends and lead joints including burning out lead joint and recovering lead complete all as specified as directed. |
| 10 | Taking up or down steel tubing along with fittings such as tee, bends etc fixed to walls and ceilings or laid in flours/trenches and connections incl removal from site of 80 mm dia pipe complete all as specified as directed. |
| 11 | Taking up or down steel tubing along with fittings such as tee, bends etc fixed to walls and ceilings or laid in flours/trenches and connections incl removal from site of 50 mm dia pipe complete all as specified as directed. |
| 12 | Taking up or down steel tubing along with fittings such as tee, bends etc fixed to walls and ceilings or laid in flours/trenches and connections incl removal from site of 40 mm dia pipe complete all as specified as directed. |
| 13 | Taking up or down steel tubing along with fittings such as tee, bends etc fixed to walls and ceilings or laid in flours/trenches and connections incl removal from site of 25 mm dia pipecomplete all as specified as directed. |
| 14 | Supplying, laying and testing 150 mm nominal dia ductile iron pipe , spigot and socket including Rubber joints class K-7 complete all as specified and as directed. Note :- Specials and fittings shall be measured and paid separately. |
| 15 | Supplying, laying and testing 100 mm nominal dia ductile iron pipe , spigot and socket including Rubber joints , class K-7 complete all as specified and as directed. Note :- Specials and fittings shall be measured and paid separately. |
| 16 | S & F GI tubing medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc laid in trenches for 80 mm bore pipes complete all as specified and as directed |
| 17 | S & F GI tubing medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc laid in trenches for 50 mm bore pipes complete all as specified and as directed |
| 18 | S & F GI tubing medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc laid in trenches for 40 mm bore pipes complete all as specified and as directed |
| 19 | S & F GI tubing medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc laid in trenches for 25 mm bore pipes complete all as specified and as directed |
| 20 | S & F GI tubing medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc fixed complete to walls and ceiling or laid in floors for 40 mm bore pipes complete all as specified and as directed |
| 21 | S & F GI tubing medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc fixed complete to walls and ceiling or laid in floors for 25 mm bore pipes complete all as specified and as directed |
| 22 | S&F Ductile iron fittings such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction, double branch, cross (all socket or socket and spigot or flanged and socket etc) color, caps and plugs suitable for DI pipe upto 150 mm dia complete all as specified and as directed. |
| 23 | M&L for construction of brick massonry valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement including demolision of old valve pit complete all as specified and as directed. |
| 24 | S&F in repairs cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc including dismantling of existing unserviceable one for the 150mm dia pipe complete all as specified and directed |
| 25 | S&F in repairs cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc including dismantling of existing unserviceable one for the 100mm dia pipe complete all as specified and directed |
| 26 | S&F in repairs cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc including dismantling of existing unserviceable one for the 80mm dia pipe complete all as specified and directed |
| 27 | S&F gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe fixed of 50mm dia incl taking down old unserviceable one complete all as specified and directed |
| 28 | S&F gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe fixed of 40mm dia incl taking down old unserviceable one complete all as specified and directed |
| 29 | S&F gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe fixed of 25mm dia incl taking down old unserviceable one complete all as specified and directed |
| 30 | M&L for cutting the existing pipe line insertion of Tee or fixing of slucie valves except DI specials complete all as specified and directed. Please Enable Macros to View BoQ information |
| 31 | M&L for cutting the existing pipe line insertion of Tee or fixing of slucie valves except DI specials complete all as specified and directed. Please Enable Macros to View BoQ information |