| 1 | BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: REPAIR/MAINT OF CHILLER, COOLING TOWER AND CONNECTED ACCESSORIES OF CHNC UNDER GE (UTILITIES) UDHAMPUR Contract No: CWE/U(U)-20/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | M&L for comprehensive maint, Preventive and routine maintenance of 03 Nos of chilling machines Make : M/s Carrier of screw type compressor, 750 TR each, single stage, 3000 RPM, 415 Volts, 3 Ph, 50 Hz, shell & tube type condenser with carbon steel plate, copper tube, including carbon plate shell & tube flooded type chiller unit working with microprocessor base controls in sheet metal control panel,VFD control panel including busbar and connected accessories complete all as directed with following requirement / condition and for following items / equipment - |
| 3 | Note : (a) The 04 (Four) preventive / periodical maintenance services and 01 (one) yearly comprehensive maintenance service to each chiller machines (03 nos) of Make : M/s Carrier of screw type compressor, 750 TR each, single stage, 3000 RPM, 415 Volts, 3 Ph, 50 Hz, shell & tube type condenser with carbon steel plate, copper tube, including carbon plate shell & tube flooded type chiller unit working with microprocessor base controls in sheet metal control panel during the currency of the contract. The contractor shall submit the record of periodical/preventive/Annual maintenance services carried out by only M/s Carrier (OEM) along with documentary evidence for claiming payment. |
| 4 | (b) The repair / replacement cost (M&L) of all defective parts / spares, as and when required, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect at any stage.(c) During entire contract period, any defective component(s) and/or any other materials which is not specified /given in Schedule ‘A’, but essential to be repair/replace, to make plant(s)/machine(s) fully functional, the cost of the same is deemed. |
| 5 | (d) The entire work as mentioned in srl item no 1.00, shall be got executed through OEM i.e. M/s Carrier AC & Ref Ltd only. The contractor shall upload / submit the scanned copy of MOU with OEM i.e. M/s Carrier AC & Ref Ltd, along with tender document, failing which the tender application / bid will be summarily rejected. The contractor will also submit the physical copy of MOU along with their application and DD in the office of tender inviting authority prior to bid opening date (Cover 1) failing which bid submitted by the contractor will be summarily rejected. |
| 6 | (e) The chiller machines along with connected items will be handed over to contractor in running condition, but with fair wear & tear which can be meet out through annual comprehensive maintenance. Hence, the bidder is advised to visit the site to assess the quantum of work to be carried out in this contract and quote their rates accordingly and no claim in this effect will be accepted at any stage. |
| 7 | (f) All the complained / faults will be addressed within 30 min from the time of receipt of complaint. If, contractor or his tradesmen fails to attend the complained within 30 min from the time of receipt of complaint, the compensation/penalty of Rs. 500.00 (Rupees Five Hundred only) per complaint per hr for first 04 hrs and after that Rs. 1000.00 (Rupees One Thousand only) per complaint per hr shall be recovered from the contractor’s dues. |
| 8 | (g) The cost of transportation (to and fro) and other necessary equipment shall be arranged / brought by contractor to complete the job and no extra cost shall be paid to the contractor in this effect. |
| 9 | M&L for complete overhauling of Primary pump/Secondary pump / chiller centrifugal pump set of 120 /100 HP by engaging sufficient man power and suitable T&P to ensure safety of pump-motor as well as working persons including disconnecting suction & discharge water lines and removing of electric connection, dismantling the U/S pump set from MS foundation, detaching the pump, opening the pump, re-metaling the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc. as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump body; complete replacement of impeller set with new; replacement of Cushy foot anti vibration pad with and including carrying out complete repair / replacement of damaged parts i.e. bearings, bush, gland plate, Pump seal, coupling assembly etc. and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc.; checking the alignment; reconnecting the suction and delivery pipes, making proper electric connection, testing and commissioning for smooth operation at optimum efficiency, complete all as directed. |
| 10 | All as per srl item no 2 here-in-before but for 15 HP capacity. |
| 11 | M&L for dismantling of electric driven horizontal induction motor of capacity 100/120 HP of any type and make, by engaging sufficient man power and suitable T&P to ensure safety of pump-motor as well as working persons including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class \\"F\\"), sealing compounds etc. and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc. and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as directed.Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect. |
| 12 | All as per srl item no 4 here-in-before but for 15 HP capacity. |
| 13 | All as per srl item no 4 here-in-before but for 12.5 HP capacity. |
| 14 | Supply and fix Refrigerant(134A) of high quality for 03 Nos of chiller units of 750 TR each complete all as specified and directed. |
| 15 | Supply and fix temprature gauge bottom connected, direct mounted type, of temperature range of 0 - 100°C or 32 - 212°F, complete all as specified and directed. |
| 16 | Supply and fix Pressure gauge, bourdon type, 150 mm dial size, pressure range 0-14 Kgs, complete all as specified and directed. |
| 17 | Supply and fix , of Air Vent valve, 20 mm dia ISI marked with and including all fixing accessories, complete all as specified and directed.Make : Rapid Cool/ZOLOTO/ |
| 18 | M&L in replacement, for PVC fins Box suitable for cooling tower of 750 TR capacity, FRP induced draft type (Model : 2FM25), complete all as specified and directed.Make : Mihir/Paharpur |
| 19 | M & L for servicing of cooling tower 750 TR of AC plat FRP Type by dismantling ad taking out the one comb PVC files complete ad PV Nozzles the PVC files by suitable descaling solution including bruising and cleaning complete with cleaning solution and water replacing the defective PVC flange along with rubber gasket and rusted bolts nuts and washer etc cleaning the water sump ad XMP wire mesh with suitable cleaning solution re-assembling the same including replacing the defective water filter flanges of pipe joints etc and testing complete all as specified and directed. |
| 20 | Supply and fix in replacement sprinkler suitable for 750 TR capacity cooling tower alongwith all necessary fittings complete all as specified and directed. |
| 21 | M& L in replacement of aluminium fan blade complete set suitable for cooling tower motor of cap. 750 TR complete all as specified & directed . |
| 22 | M& L in replacement of new hub of cooling tower gear box complete all as specified & directed . |
| 23 | Supply and fix FRP FAN ASSY 2700MM complete all as specified and directed |
| 24 | M&L in replacement, of CI butterfly valve, ISI marked, PN - 1.6 pressure grade, having Nitrile/EPDM rubber lining, SS stem, CS/SS disc, gear operated type, of size 300 mm dia bore including all jointing material i. e. nut, bolt, washer, packing material etc., duly insulated, complete all as specified and directed. |
| 25 | M&L in replacement, of CI Double regulating balancing valve (Flanged) with Nozzle, ISI marked, PN - 16 pressure grade, of size 300 mm dia bore including all jointing material i. e. nut, bolt, washer, packing material etc., duly insulated, complete all as specified and directed. |
| 26 | Supply and fix three phase power contactor MO 12 type ,Aux contact 1NO+1NC of capacity 32 Amps 415 Volt 50 Hz, coil voltave 415Volt including cable with connection as per site requirment and taking down unserviceable one all as specified and directed and apecified by Engr-in-Charge. |
| 27 | All as per item No 19 here -in- above but MO 110 capacity 140 Amps . |
| 28 | S & F Electronic Motor Protection relay VSP 3 with in built earth fault protection including protection with Earth fault/Over load/ lockroter/ Single phasing / Current unbalance / under current / trip indication / test facility of Aux supply 415 Volt and thermal range 32-100 Amps Capacity all as directed and specified by Engr-in-Charge. |
| 29 | M&L for servcing of air Handling Unit of capacity upto 24000CFM by opening of both side cover taking out the Fresh air filter cleaning the External & Internal surface of AHU, Primary air filter, wire mesh filter, Tumble Blower fan and re-fixing the side covers head covers after cleaning of evapration coil with chemical including replacing the suitable gasket complete all as specified and directive by Engineer in charge for the following :(Necessary Nut, Bolts, washers, pickings are included in quoted rate ) |
| 30 | M & L in replacment of unserviceable 3 way modulating motorized valve (glow type),GI globe body,Brass seating,SS-304 spindle ,Telflon gland,with linear movement actuator 24 V AC input supply,0-10Vinput signal with modulating thermostate & transformer of size-25 mm Model M912-B Make:-SIEMENS/RAPID CONTROL/RAPID COOL |
| 31 | M&L for cooling tower Gear Oil as per existing sample or direction by OEM all as specified and directed by Engr-in-Charge |
| 32 | M&L crystal type salt of sodium chloride 25 Kg Bag for water softening plant @ 3 Kg/day complete all as directed. |
| 33 | S& F in replacemet of compressor oil (18.9 Ltrs) suitable for 750 TR Chiller all as directed |
| 34 | Supply and mixing Anti scalant for cooling tower MAXTREAT-2515 all as specified and directed. |
| 35 | M&L for Servicing of the AC plant VFD (Variable Frequency Drive) panel for 750 TR chiller and Secondary pump (120X2)HP VFD, after disconnecting all incoming and outgoing electric connections, followed by thorough inspection of all internal components. The panel is cleaned to remove dust and moisture, and all electrical connections and terminals are checked for tightness and signs of overheating.updating the programming as per the suitable timing requirement of frequency, voltage, overspeed,flow speed etc, VFD parameters, fault logs, and protection settings are reviewed and verified as per operational requirements. Cooling fans, air filters, capacitors, and control wiring are inspected and tested. Input/output voltage, current, and earthing are checked to ensure proper functioning. After servicing, the VFD panel is re-energized, and complete testing and commissioning all as specified and directed by Engr in Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |