| 1 | Demolition of stone/brick masonry built in cement mortar incl all quions, Arches, pillers etc complete all as specified and directed. |
| 2 | M&L for brick work with using sub class 'B' brick ,straight or curved on plan exc. 6 meter radius, built in CM (1:6) for wall complete all as specified and directed. |
| 3 | Description all as per item Sr No. 2.00 here in before but except brick complete all as specified and directed. |
| 4 | Demolition of cement concrete in ground floor and pavings n exe 15 cm thickness (below or above ground level ) (unreinforced ) complete all as specified and directed. |
| 5 | M&L for Plain cement concrete 1:5:10 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 6 | M&L for PCC 1:3:6, type C1 ( using 20 mm graded stone aggregate ) as in leveling course, coping, benching, flooring,surface channel / sub base drain finishing cement concrete surface incl forms / mould complete all as specified and directed. |
| 7 | Taking down cement plaster of any description on brick or stone walls or from concrete surface incl racking out joints hacking for key scrubbing with water etc complete all as specified and directed. |
| 8 | M&L for rendering 15mm thick with CM 1:4 on fair faces of brick work, finishing fair and even without using extra cement complete all as specified and directed. |
| 9 | M&L for Preparation of newly plastered wall surfaces and appling two coats of cement base paint over a coat of primer complete all as per specified and directed. |
| 10 | Dismantling mild steel work of any description complete all as specified and directed. |
| 11 | S&F joist channel, MS pipe, angel, flat, or tee section as in post and strut in fencing including drilling holes notching for wire etc, flat iron fillet (for securing wire mesh/chanelling fencing) incl all necessary drilling riveting ,bolts etc. similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 12 | M&L for praparation of newly steel surface over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 13 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 14 | Excavation in post holes each n.exc 0.5cum getting out in any type of soil returning filling in and ramming earth or broken rubble mixed in layers n.exc 25 cm and covering and removal of surplus soil n.exc 50 m and making good surface complete all as specified and directed. |
| 15 | Dismantling fencing wire mesh any type complete all specified and directed. |
| 16 | S&F in repair MS galvanised chain link fencing (Weight Not exc 4 Kg per Sqm / as approved by GE ), rail straining bolts, tec incl provission of binding wire,of any description complete all as spfd and directed. |
| 17 | S &F in repair galvanised 2 strand 2.24 mm dia steel barbed wire, barbed with 2mm dia barbs at 75mm (approx) spacing and straining and fixing to any type of post straining bolts, including securring or typing at crossing with and including complete all as specified and directed. |
| 18 | M&L for repair precast cement concrete louvres and jallies type B-0 1:2:4 (12.5 mm graded stone aggregate ) 35mm thick, set in CM 1:4, measured solid including all mouldings, frame and necessary reinforcement complete all as specified and directed. |
| 19 | Dismantling/ demolition posts or struts embedded in soil or concrete etc (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 20 | M&L for Welding in repairs, length n.exc 2.5 cm, thickness of mild steel members to be welded shall not exc 6 mm complete all as specified and directed. |
| 21 | M&L for Welding in repairs, lenght exc 2.5 cm but n. exc 5 cm, thickness of mild steel members to be welded shall not exc 6 mm complete all as specified and directed. |
| 22 | S&F 0.80 mm thick mild steel, plain, black sheet as in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 23 | Demolition of reinforced cement concrete cover slab (reinforcement cut as required to facilitate demolition) (below or above ground level) completed all as specified and directed. |
| 24 | M&L Providing cover slab 1:2:4 type B 1 using 20 mm graded aggregate set in cement mortar 1:6 as in cover slab including placing in position complete all as specified and directed. (Note : - reinforcement shall be measure and paid separtely under respective item of sch A. |
| 25 | M&L for mild steel TMT bars of 10mm dia and over, dia cut to length bent to shape required including cranking bending spirally for hoopinf for column, hooking ends and binding with mild steel wire not less than 0.9 mm dia(annealed) or securing with cips complete all as specified and directed by Engr-in-Charge. (Note - The payment shall be made only after placing of cover on manholes. |
| 26 | M&L for Preparation of old plastered wall surfaces and appling one coat of cement base paint complete all as per specified and directed. |
| 27 | M&L for two coats of oil bound distemper over a coat of average 2mm thick Birla putty on old plastered surfaces including preparation of surface slab complete all as specified and directed. |
| 28 | M&L for preparation of old plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 29 | M&L for preparation of old plastered surface of wall and applying two coats of exterior emulsion (Apex ) over a coat of primer complete all as specified and directed. |
| 30 | Repairs to steel gate /wicket gate of any width incl replacement pintle hinges, mild steel aldrop bolt , if required necessary welding, reveting, drilling,oiling , greasing for easying the gate complete all as specified and directed. |
| 31 | S&F Reinforced concrete pipe, bore of pipe 200mm , class NP2, laid and jointed complete with collers completed all as specified and directed. |
| 32 | M&L PCC 1:3:6 (using 20mm graded crushed stone aggregate) as in bed to drain pipes ( bore of pipes is 200 mm) including packing under and completely surrounding pipes with concrete after they are laid and tested in complate all as specified and directed. |
| 33 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 30cm deep and getting out of soft loose soil complete all as specified and directed. |
| 34 | M&L for hardcore of gauge not exceeding 63 mm of broken stone/boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface. |
| 35 | M&L for 25 mm thick sand cushion layer for laying interlocking pavers complete all as specified and directed. |
| 36 | M&L for 80 mm thick precast PCC interlocking coloured paver rubber moulded block factory made of grade M 40 single layer monolithic high density manufactured by electro vibro hydraulically operated block making maching conforming to IS -15658- 2006 laid and jointed over sand cushion layer complete all as specified and directed. Note : Sand cusion shall be measured & paid separately |
| 37 | M&L prepolished, machine pressed chequred cement concrete coloured tiles 30cm x 30cm x 25 mm thick, set , jointed and pointed in neat cement slurry with mixer of white cement and pigmenet as in floors/pavements/ paths laid over screed bed or bedding layer in cement mortar 1:4, 20 mm thick screed bed complete all as specified and directed. |
| 38 | M& for Machine cut & polished smooth surface of kota stone slab 18-20mm thick as in skerting, including 15 mm thick cement mortar screed bed 1:4 fix in position etc complete all as specified and directed by Engr-in-charge. |
| 39 | M&L for Machine cut & polished smooth surface of kota stone slab 20-25mm thick as in flooring, including 20 mm thick cement mortar screed bed 1:6 fix in position etc complete all as specified and directed by Engr-in-charge. |
| 40 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises, complete all as specified and directed by Engr-in charge. |
| 41 | M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plat forms , wash hand basin slab, urinal partition etc and like over and including 15 mm thick bedding in cement mortar (1:4) pointing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite including Dismentling of stone slabs and tiles of any description or thickness in floors, approns etc,laid bedded and pointed in any mortar complete all as specified and directed by Engr-in charge. |
| 42 | Repair to rolling shutter without taking off rolling shutter securing or easing, cleaning, greasing, oiling, welding in gear box, crank handle , rolling spring channels, ball bearing, pully, adjustment of lock device, pinion, gear box, shaft spring etc.& any description complete all as specified and directed. |
| 43 | M&L for applying one coat of synthetic enamel paint on old painted wooden surfaces of any description complete all as specified including preparation and complete removal of existing treatment complete all as specified and directed. |
| 44 | M&L for applying one coat of synthetic enamel paint on old painted steel surfaces of any description complete all as specified including preparation and complete removal of existing treatment complete all as specified and directed |
| 45 | S&F in repair Rotational moulded polyethene water storage tank( cylindrical vertical with closed top) hoisted and fixed in position capacity 500 ltr including dismantling of existing water tank and connecting to outlet GI 20mm dia pipe including fitting complete all as specified and directed. |
| 46 | Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc., capacity of tank exc 500 & n exc 1000 litres including writing date of cleaning on the tank with suitable synthetic enamel paint etc complete all as specified and directed. |
| 47 | Cleaning and desilting of sewage line/drain of any size including removal of rubbish mixed with earth etc. and disposal of same complete all as specified and directed. |
| 48 | Removing of old treatment from old concrete floor/terrace taking down existing detoriated / decayed tarfelt or any treatment including loose surface, scraping with scraper, chiseling.scraping of surface with wire brush of any other method. sweeping clean & washing down with water to remove dust etc and removing the scraped materials debris to a distance not exc. 1000 m complete all as specified and directed. |
| 49 | M&L for 15-20mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) :4 graded stone aggregate 12.5 mm nominal size) for grading roof for water proofing treatment, coping of parapet walls roof in levelling course etc with WPC complete all as specified and directed.Note:- WPC shall be measured and paid separately. |
| 50 | Supplying only liquid water proofing compound ISI Makrs (used 200ml / bag of cement complete all as specified and directed. |
| 51 | Supply and applying bituminous solution primer on roof and / or wall surface at 0.24 litre per sqm. complete all as specified and directed. |
| 52 | S&F one layer of APP based polymeric membrane minimum weighing 3 Kg/ Sqm & minimum 3 mm thickness reinforced with polyster non woven fabric (wt not less than 150 gms/ sqm) laid on primed surface by propane torch application complete all as specified and directed with lap of 100 mm and the over lap shall be sealed by flame. NOTE:- The work of water proofing treatment shall be got executed throughh expert team of manufacturers or authorised applicator of manufacturer. |
| 53 | M&L for Applying two coats of aluminum paint on top of membrane for Non accessible roof NOTE:- The work of water proofing treatment shall be got executed throughh expert team of manufacturers or authorised applicator of manufacturer complete all as specified and directed. |
| 54 | S&F in repair 110 mm dia pvc (SWR ) pipes single socket in any length laid in trenche , drain wall or in floors completes all as specified and directed. Please Enable Macros to View BoQ information |