| 1 | HSR PART[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate] |
| 2 | [11.6.1]15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) [Through Rate] |
| 3 | [11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. [Through Rate] |
| 4 | [11.67.1]Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primer [Through Rate] |
| 5 | [11.71.1]Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work [Through Rate] |
| 6 | [11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. [Through Rate] |
| 7 | [13.18]Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect. [Through Rate] |
| 8 | [13.29.1]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 1. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete [Through Rate] |
| 9 | [13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works [Through Rate] |
| 10 | [20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) [Through Rate] |
| 11 | [20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate] |
| 12 | [20.84]Providing and fixing of insulated rubber matting suitable for 11 KV installation 1 M x 2 M x 12 mm thick (IS code 15652-40091) as per specification complete and as per directions of Engineer-in-charge [Through Rate] |
| 13 | [20.86]Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects. [Through Rate] |
| 14 | [23.20]Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required [Through Rate] |
| 15 | [23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA [Through Rate] |
| 16 | [23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate] |
| 17 | [23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA [Through Rate] |
| 18 | [23.22.1.13]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.13. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 600 to 800 Amp , 50 KA [Through Rate] |
| 19 | [23.22.1.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA [Through Rate] |
| 20 | [23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA [Through Rate] |
| 21 | [23.22.1.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.7. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 400 Amp, 50 KA [Through Rate] |
| 22 | [23.22.2.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP [Through Rate] |
| 23 | [23.22.2.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.3. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB above 250 A and up to 630 A FP [Through Rate] |
| 24 | [23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) [Through Rate] |
| 25 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] |
| 26 | [23.22.8.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.4. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 300 amp 415 volts [Through Rate] |
| 27 | [23.22.8.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.5. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 400 amp 415 volts [Through Rate] |
| 28 | [23.24.4.1]MS STAND, BUS BAR CHAMBER AND PANELS 4.1. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 4 way 250 amp. [Through Rate] |
| 29 | [23.24.4.3]MS STAND, BUS BAR CHAMBER AND PANELS 4.3. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 4 way 400 amp. [Through Rate] |
| 30 | [23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate] |
| 31 | [23.27.5]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 5. M.S. pedestal of size 1200 mm wide ,1500 mm high ,450 mm deep and bottom totally open , duly embeded in cement concrete block of size 1350 mm x 600 mm x 200 mm above ground level , having a base of size 1500 mm x 750 mm x 250 mm below ground level . 0 0 [Through Rate] |
| 32 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 33 | [23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate] |
| 34 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 35 | [24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 36 | [24.1.14]EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size. [Through Rate] |
| 37 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 38 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 39 | [24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate] |
| 40 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 41 | [24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate] |
| 42 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 43 | [24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate] |
| 44 | [24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate] |
| 45 | [24.13.40]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 40. 35 Sq mm 4 core (Arm.) [Through Rate] |
| 46 | [24.13.70]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 70. 120 Sq mm 3.5 core (Arm.) [Through Rate] |
| 47 | [24.13.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94. 300 Sq mm 3.5 core (Arm.) [Through Rate] |
| 48 | [24.16.2]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 2. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 50 Sq mm 3 core [Through Rate] |
| 49 | [24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm [Through Rate] |
| 50 | [24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate] |
| 51 | [24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm [Through Rate] |
| 52 | [24.2.8.6]LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm [Through Rate] |
| 53 | [24.2.9.7]LT CABLE 9.7. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 185 sqmm Cable 300 sqmm cable 3 to 4 Core [Through Rate] |
| 54 | [24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate] |
| 55 | [24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate] |
| 56 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate] |
| 57 | [24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia [Through Rate] |
| 58 | [4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate] |
| 59 | [6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 60 | [6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 61 | [7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate] |
| 62 | NS PARTSupply and erection of LED Flood light 250 Watt, operation on single phase AC supply complete in all respect up to the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. |
| 63 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 64 | Providing and fixing of 6 Kgs capacity ABC stored pressure type ISI marked fire extinguisher IS:15683 with 90% MAP powder complete in all respect with the entire satisfaction of Engineer-Incharge. (Make:Omex/Lifeguard/ Safex). |
| 65 | Supply and erection of Fire Extinguisher ISI marked CO2 type of 4.5 Kg capacity as per IS :7285 duly erected/ hags on wall with hooks i/c the cost of hook, screws etc. with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in Charge of the work. |
| 66 | Servicing and Testing of 50/62.5 KVA D.G Set with Cleaning and lubrication of all moving parts including complete Premium Oil ,lube Oil Filter, Inhibitor Corrosion, Separator Fuel Water, Element Air Filter primary and secondary, V Belt, Fuel Filter Element Primary and secondary, Fuel Pipe etc. complete with handling and services charges and all other petty material to Complete the job in all respect with all labour upto entire satisfaction of EIC of the work. |
| 67 | Supply of 18/20 watt rating 4 feet long LED Tube light Batten suitable for operation on 230 volt, 50 Hz supply. |
| 68 | Supply and erection of LED light 2` x 2` 36 Watt, operation on single phase AC supply upto 35000 working hour complete in all respect up to the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. |
| 69 | Supply, Installation, Testing and Commissioning of UL/FM Certified Extinguishing agent filled in PESO Approved Filling Station: 2 Kg FK-5-1-12 Clean agent filled in PESO approved stored pressure type seamless steel cylinder as per IS 7285 (life 15years) with automatic type DLP valve assembly PI marked, TPED (Transportable Pressure Equipment Directive) approved, Used Standards for type approvals ISO 17871:2015 in conjunction with EN ISO 10297:2014 EN ISO 14246: 2017-12, Push in connector, End of line adapter, UL listed Pr. Switch, end of line plug, T connector, Safety Burst Disc at 28 Bar and Mounting Bracket. Stored Pressure type fitted with Pressure gauge, UV Resistance, Operating Pressure 15 bar, Hydraulic Pressure Tested to 250 bar, Burst Pressure at 350 bar, Red Powder coated. Certified by National Test House, Dept of Consumer Affairs, Govt. of India. system design as per NFPA 2001 and Installed as per LPS 1666 |
| 70 | Supply, Installation, Testing and Commissioning of Master Control Unit inbuilt A/v alarm Control Panel along with sounder cum strobe of 24VDC operated red colour MS housing , 2 NO/NC potential free relay contact for Main Fire Alarm. Modbus for BMS Integration. Gas discharge led indicator, battery led indicator, system status Led indicator, AC power ON Led indicator. |
| 71 | Supply, Installation, Testing and Commissioning of UL Certified Linear pneumatic Heat Detection Tube (ID-6mm and OD-8mm) for automatic fire detection and suppression system made by special modified polyimide (PA), colour red RAL300, burst temperature 1310C, inner diameter 6mm, outer diameter 8mm. Pressurized with dry nitrogen at 15 bar pressure with all necessary fittings and supports. Certified by National Test House, Dept of Consumer Affairs, Govt. of India. |
| 72 | Supply, Installation, testing and commissioning of cubical type dust and vermin proof H.T. Metering panel free for standing floor mounting suitable for 11 KV 3 Phase supply made out of14 gauge MS sheet with channel from base frame painted with staving synthetic light gray enameled paint suitable for operation on 11 KV 3 Phase four wire 50 cycle systems effectively earthed system and consisting of the followings:- i) 3nos 11 KV C.T of required capacity with burden class 0.5 S of approved make by HVPN. ii) ONE No PT 11KV/110 volts 3 phase oil cooled 10 VA class 0.5 of make as approved make by HVPNL .iii) 2 NOS cable holes for incoming and outgoing 11KV cable. iv)Wiring and terminal block v) THE panel will be complete with all internal wiring, inter connection of VT and HT, compound filling of cable and boxes, HT cable connections etc. complete in all respect as approved by UHBVN/DHBVN authorities including the cost of security for H.T. Meter, testing fee of CTs, PT another equipment`s as required by UHBVN/DHBVN authorities. |
| 73 | Supply and erection of 11 Meter PCC pole including excavation and refilling with soil, ramming and compacting in all respect as per DHBVN specifications and upto entire satisfaction of Engineer incharge of the work. |
| 74 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 75 | (Main LT panel) Supply, Installation, testing and commissioning of cubical type fully interlock AMF main L.T. panel dust and vermin proof free standing floor mounting made out of 2MM thick CRCA sheet with 75mmx40mmx6mm channel iron base frame painted with stove enameled power coated paint suitable for operation on 3 phase 4 wires 50Hz A.C. supply having ammeter and voltmeter and indicating lamp. (Overall size of panel appro.2800mmx600mmx2150mm) Excluding the cost of MCCB`s but including the cost of following items INCOMING: - 1 no. MCCB 630 AMP. 4 POLE 50 KA(space only) THERMAL MAGNATIC RELEASE with OVERLOAD SETTEING Suitable for operation on 400/440 volts 3 phase, 4 wire 50Hz AC supply: - INCOMING: - (for D.G. 1 space only) 1 no. MANUAL CHANGEOVER 400 AMP. 4 pole. Suitable for operation on 400/440 volts 3 phase, 4 wire 50Hz AC supply. INCOMING: - (for D.G. 2 space only) 1 no. MANUAL CHANGEOVER 250 AMP. 4 pole. Suitable for operation on 400/440 volts 3 phase, 4 wire 50Hz AC supply. Position 1 and Position 2 indicator independent for changeover. 1 Nos Multifunction meter with RS485 port(volt, ampere, KWA, Power factor) 0- 1000 amp, independent for Main MCCB. 2 Nos VAF Meter 0- 1000 amp, independent for changeover. Indicating lamp, Red, Yellow, Blue = 1 Set . 2 no. set of CT’s of VA 5 burden and accuracy class `1` and having rating of 600/5-5 amp. for ammeter. 1 no. set of CT’s of VA 5 burden and accuracy class `1` and having rating of 250/5-5 amp. for ammeter. BUS BAR CHAMBER: - Aluminum bus bar 720 amp. 415 volts having aluminum bars 4 strips duly covered with heat shrinkable sleeves with required cleaners as per ISS size of 720 A. 4 nos. aluminum bars duly covered with transparent acrylic sheet in the front. Terminal arrangement: - compression type cable glands and Aluminum lugs/thimbles for incoming and outgoing cable of required capacity of 3.5 core at least 20 nos. cables. Outgoing: The L.T. panel should be having sufficient space for accommodating the following switches / MCCB`s. 6 Nos. 250 amp. 3 phase MCCB (space only) . 6 Nos. 200 amp. 3 phase MCCB (space only). 3 Nos. 160 amp. 3 phase MCCB (space only) . All MCCB rotary control duly interlocked. Earthing: - Aluminum bus bar of cross section 32 x 6mm duly tinned though out the length of panel. ( LT POWER FACTOR PANEL) : - Supply, installation, testing and commissioning of cubical type panel dust and vermin proof. free standing floor mounting made out of 2MM thick CRCA sheet with 75mmx40mmx6mm channel iron base frame painted with stove enameled power coated paint L.T. automatic power factor control panel 250 KVAR capacity suitable for automatic operation and control of power factor within the set limits suitable for operation on 3 phase 4 wire 50 Hz 400/440-volt s A.C. supply. Comprising of: - 1 No. automatic power factor control relay. Power factor digital meter. Incomer 320 amp. Triple pole molded case circuit breaker Iron clad bus bar chamber suitable for 400 amp. 440 volts having 3 No. ALUMINIUME bus bar of cross section 50 mm x 10mm duly tinned and insulated with PVC sleeves Connection from incomer molded case circuit breaker to bus bar by means of solid ALUMINIUME strip of requisite capacity duly tinned and insulated with PVC sleeving. 3 phase dry capacitor (totaled 250 KVAR) matching from 1 KVAR to 25KVAR Required capacity 3 phase. Contractor independent for each capacitor Required capacity 3 Pole MCB independent for each contractor indication LED Lamps 220 volts for ON indicator of respective capacitor SELECTOR SWITCH AUTO MANUAL Operation respective Earthing ALUMINIUM bus bar of cross section 32 mm x 5 mm duly tinned and insulated through the length of panel. The panel will be complete with all internal wiring with PVC copper wire, inter connection etc. in all respect with all labour and material require to complete the job in all respect excluding the cost of MCCB up to the entire satisfaction of the Engineer-in-charge of the work. |
| 76 | Supply and erection of transformer of standard make Required 200 KVA 11/0.433 KVA rating IS1180.level- II outdoor type Off- Circuit Tap Changer Oil Natural Air Natural copper winding. Temperature rise oil/winding 40/45. vector group reference dyn11.insulation HV/LV-uniform. BIL HV=75KVP/28 KVrms BIL LV= -KVP/3 Kvrms. Taps on winding -a)tapping range plus 5%to-10%.b)no of steps -6 [email protected]%.paint type PU polyurethane. Insulating oil asper IS335 Nolse level for offered transformer will be as per NEMA TR1 only. Overloading capacity of offered transformer will be as pe IS6600 only. encloser for marshalling box will be of protection class IP55.fenced enclosure for transformer, and any other contingent there to complete in all respect as per approved make and directions of Engineer-in-charge as per respective capacity |
| 77 | Supply and erection of 45 Watts LED IP66 street light fitting white colour, pressure die cast aluminium street light luminary, operation on single phase 240 v AC supply with minimum 50000 working hours ,120 Lumens /watt with power factor )0.95 with petty material required for connections to complete the job in all respect up to the entire satisfaction of engineer- in charge of the work . Please Enable Macros to View BoQ information |