| 1 | Dewatering arrangement including fixing of low head high discharge mud pump with suction of delivery pipe as required |
| 2 | Manufacturing of special and pipes made out steel plate of HR coils 8MM to 10 MM thick plate in shape and size condition I/C cost of steel plate and other electricals and mechanical material i/c submerged are welding i/c cost of transportation, loading & unloading complete pipe and special barel piece, gap piece, spigot and socket end, plain & socket clamp etc.as per site condition |
| 3 | Higher charges for diesel generator set / electric connection from electric pole for cutting, welding of MS pipe and dewatering work and lightening arrangement etc. complete |
| 4 | Charges for lighteing, berickating and traffic diverting from leackage site with safety arrangement during leackage repairing work i/c fixing of bulli, wire rop, alojan lamp, cuation board, caution flag for the traffic diversion and removing all these material after completion of work from site i/c loading, unloading & 1 Days X12 Month |
| 5 | Providing and fixing gland rope 6 mm dia as per IS 5414days 1995 make champion/turner/ equivalent |
| 6 | Providing and fixing gland rope 10 mm dia as per IS 5414- 1995 make champion/turner/ equivalent |
| 7 | Provision for making arrangement for electricity from MPEB to run welding transformer, de watering pump and grinding machine, lamp etc.complete at site. |
| 8 | Manufacturing and supply of MS volve operating key and following size of sluice volve made out by single piece as per standard and site condition 150 mm dia |
| 9 | Providing & fixing of neoprence rubber sheet 3 & 6 mm as per I.S.-638-1979Make TRPL/National/Equivalent |
| 10 | Providsing & fixing of nut bolt, washer, size as per requirement aas per I.S. 1363-1992 &I.S.-4218 part - 5 -1967 make Tata/GKW/Standard/ Equivalent |
| 11 | Fabrication & Providing of extra of Extra long 3 mtr MS key as per sample made MS rod 25 mm thick & MS cap molded on the sluice valve spindle &grouting 50x50x8 mm angle clamp in the chamber wall sluice vlave open & close work at Gambhri line section |
| 12 | Providing & fixing Rubber ring |
| 13 | 80 MM dia |
| 14 | 100 MM dia |
| 15 | 150 MM dia |
| 16 | 200 MM dia |
| 17 | Supply of wooden Handle hand made for spread & axxis |
| 18 | Labour charges for shaftning of chisel, axxis & Digging rod |
| 19 | Providing and fixing spun yarn Best quality |
| 20 | Providing and fixing of lead wool containing 90 % lead as per IS-318-1981 |
| 21 | Providing & fixing pig lead 99% pure |
| 22 | Providing & applying of M-seal compound make mahindra |
| 23 | supply of SS 410 spendal rod without GM chek nut for following dia S/V |
| 24 | 80 MM dia |
| 25 | 100 MM dia |
| 26 | 150 MM dia |
| 27 | 200 MM dia |
| 28 | supply of SS 410 spendal rod for following dia S/V (Old material not refundable) |
| 29 | 250 mm |
| 30 | 300 mm |
| 31 | 400 mm |
| 32 | 500 mm |
| 33 | 600 mm |
| 34 | Recxasting of following dia sluice vlave GM check nut i.c recasting, finishing, machining and threading as per sample and cost of extra material complete work. |
| 35 | 80 MM dia |
| 36 | 100 MM dia |
| 37 | 150 MM dia |
| 38 | 200 MM dia |
| 39 | Replacement of G.M. Check Nut (Old material not refundable) in following size of sluice valve made out by single piece. |
| 40 | 250 mm |
| 41 | 300mm |
| 42 | 400 mm |
| 43 | 500 mm |
| 44 | 600 mm |
| 45 | Repairing of folowing dia sluice valve i/c fixture check nut guid both side i/c welding, finishing, cutting clamping as per size of check nut |
| 46 | 80 MM dia |
| 47 | 100 MM dia |
| 48 | 150 MM dia |
| 49 | 200 MM dia |
| 50 | 300 MM dia |
| 51 | 400 MM dia |
| 52 | Labour charges for opening and refitting of following dia sluice valve i/c cutting of old damged nut bolt, removal of damaged gland packing, rubber packing, providing, fixing of new by fabricated parts and greasing properly cost of nut bolt over-handling the valve, transportation of material T&P testing and making with risk cover as per requirement |
| 53 | 80 MM dia |
| 54 | 100 MM dia |
| 55 | 150 MM dia |
| 56 | 200 MM dia |
| 57 | 300 MM dia |
| 58 | 400 MM dia |
| 59 | Labour charges for opening and refitting of following dia S/V valve for oiling & greasing work including excavation of pit as per site requirement or cleaning work of chamber and cutting of old rusted nut bolt with chisel or gas cutter, opening, refitting of spindle rod, GM check nut with gate etc., providing and fixing of new nut bolt with washer, gland rope, rubber packing etc., fixture check nut guide work.Continuous dewatering by pump during the work, trial and testing after the completion of work including the cost of grease, transportation of the T&P and all labour with risk cover. Complete job work. |
| 60 | 80 mm |
| 61 | 100 mm |
| 62 | 150 mm |
| 63 | 200 mm |
| 64 | 250 mm |
| 65 | 300 mm |
| 66 | 400 mm |
| 67 | 500 mm |
| 68 | 600 mm |
| 69 | Labour charges only for repairing of 300 mm dia butterfly valve at water tank inlet & outlet line, cutting of old rusted nut bolt & 300 mm dia vertical horizontal C.I. pipe line by gas cutter, dismantling at damaged 300 mm dia butterfly valve, machining, welding of seat threading of valve & refitting of butterfly valve new nut bolt & welding of pipe complete. T&P testing labour charges. |
| 70 | Manufacturing & supply for water level float for indicator of overhead tank at Gambhir line section zone including labour charges & all material complete steel float unbreakable, rustproof, size 400 mm dia. |
| 71 | Hire charges of Tactor Breaker for excavation in trenches including dressing for searching and opening of leakage in 300 to 750 mm Ø C.I./P.S.C./D.I./M.S. including making of water diversion trench near leakage site for dewatering arrangement and for holding of pipes alignment for proper repairing works with lifting and taking out the damaged pipe from trench etc. |
| 72 | Manufacturing, providing and fixing of spigot & socket end, machine end suitable for 205/300/400/500/520/600/620/700/750 mm dia pipe and specials etc. (as per IS-3589-2001 for its letter revision/amendment) |
| 73 | painting work of MS pipe line by best quality oil paint. |
| 74 | Providing and fitting of bearing no. 51211 / 51212 (SKF or equivalent) on full round gear both sides complete job as per original dimension as required gear box above work for Sluice valve |
| 75 | 150mm to upto 450 mm dia |
| 76 | 500 mm to upto 600 mm dia |
| 77 | Dismantling of cement concrete pavement i/c breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead upto 1000 meter, stacking serviceable and unserviceable materials separately and as per relevant clauses of section-200. 150*2*1*0.30=9018.12/229 |
| 78 | Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed.18.2.1 All kinds of ordinary soil . =150*2*1*1 =30018.2/227 |
| 79 | Providing, Laying, Jointing & Testing of Asbestos cement pressure pipe ISI marked and conforming to IS-1592/03 tested to the required pressure including cost of pipes all complete.9.1/132 |
| 80 | 80 mm Class 15 |
| 81 | 100 mm Class 15 |
| 82 | 150 mm Class 15 |
| 83 | 200mm Class 15 |
| 84 | 250mm Class 15 |
| 85 | 300mm Class 15 |
| 86 | Labour for cutting following Asbestos Cement Pressure Pipes of any type and class.19.2/239 |
| 87 | 80 mm 6 Kg |
| 88 | 100 mm 6 Kg |
| 89 | 150 mm 6 Kg |
| 90 | 200 mm 6 kg\sqmm |
| 91 | 250 mm 6 kg\sqmm |
| 92 | 300 mm 6 kg\sqmm |
| 93 | Providing & fixing detachable joints to asbestos cement pressure pipes and fittings including C.I. detachable joints confirming to IS/8794/1988 with bolts, nuts and rubber rings9.4/133 |
| 94 | 80 mm Class 15 |
| 95 | 100 mm Class 15 |
| 96 | 150 mm Class 15 |
| 97 | 200 mm Class 15 |
| 98 | 250 mm Class 15 |
| 99 | 300 mm Class 15 |
| 100 | Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed) 6Kg/Cm27.1/103 |
| 101 | 90 mm |
| 102 | 110mm |
| 103 | 160 mm |
| 104 | 200 mm |
| 105 | 250 mm |
| 106 | 315 mm |
| 107 | 400 mm |
| 108 | Providing butt fusion welded joint/jointing by heating to the ends with the help of Teflon coated electric mirror/heater ends together etc. by thermosetting process to HDPE Pipe and specials. (6kg, 8kg, 10kg) (50mm & above fusion jointed & below 50mm mechanical jointed)7.9/108 |
| 109 | 90 mm |
| 110 | 110mm |
| 111 | 160 mm |
| 112 | 200 mm |
| 113 | 250 mm |
| 114 | 315 mm |
| 115 | 400 mm |
| 116 | Providing, laying, jointing & testing of following P.V.C. pipes with solvent cement joint for 6, 8 and 10 kg/ sq. cm. pressures including testing of joints, cost of jointing materials etc. complete in all respect.5.1/81 |
| 117 | 90 mm 6Kg/Cm2 |
| 118 | 110 mm 6Kg/Cm2 |
| 119 | 160 mm 6Kg/Cm2 |
| 120 | 200 mm6Kg/Cm2 |
| 121 | 250 mm dia 6Kg/Cm2 |
| 122 | 315 mm 6Kg/Cm2 |
| 123 | Providing and laying in position following PVC Tees, suitable for 6, 8 and 10 Kg/Sqcm. Pressure pipes.5.6/82 |
| 124 | 90 mm 6Kg/Cm2 |
| 125 | 110 mm 6Kg/Cm2 |
| 126 | 160 mm 6Kg/Cm2 |
| 127 | 200 mm 6Kg/Cm2 |
| 128 | Providing and laying in position following PVC end Cap (plugs) suitable for 6, 8 and 10 Kg/Sq cm. Pressure pipes.5.8.1/83 |
| 129 | 90 mm 6Kg/Cm2 |
| 130 | 110 mm 6Kg/Cm2 |
| 131 | 160 mm 6Kg/Cm2 |
| 132 | 200 mm 6Kg/Cm2 |
| 133 | Providing and laying in position PVC coupler suitable for 6, 8 and 10 Kg/Sq. cm. Pressure pipes.5.9/83 |
| 134 | 90 mm 6Kg/Cm2 |
| 135 | 110 mm 6Kg/Cm2 |
| 136 | 160 mm 6Kg/Cm2 |
| 137 | Labour for cutting following P.V.C pipes of any type and class.19.5/240 |
| 138 | 90 mm |
| 139 | 110 mm |
| 140 | 160 mm |
| 141 | Providing, laying, jointing, testing and commissioning of ISI marked PVC- O (Oriented Plasticized Polyvinyl Chloride) ring fit type pipe having orientation class 500 : C-1.4 with integral homogeneous spigot, elastomeric sealing ring made of EPDM rubber (one per pipe) including testing of joints, cost of jointing materials etc. Complete in all respect. Pressure Rating as per IS Code — IS:16647-2017 for following diameters.5.12/84 |
| 142 | 110 mm |
| 143 | 160 mm |
| 144 | 200 mm |
| 145 | 250 mm |
| 146 | 315 mm |
| 147 | Providing, laying, jointing & testing of socket & spigot centrifugally cast (Spun) Ductile Iron pressure pipe swith inside cement mortar lining (classK-7)with suitable Rubber Gasket (Pushon) joints as perIS:5382/85 including testing of joint.4.1/56 |
| 148 | 80mm diameter |
| 149 | 100mm diameter |
| 150 | 150mm diameter |
| 151 | 200mm diameter |
| 152 | 250mm diameter |
| 153 | 300mm diameter |
| 154 | 350mm diameter |
| 155 | 400mm diameter |
| 156 | 450mm diameter |
| 157 | Providing & laying Ductile iron Mechanical joint collar with follower glands conforming to IS-9523/2000 having dimension as per table 24 of IS-9523/2000 in the nominal diameter/sizes with external bitumen coating and internal cement mortar lining.PN 164.11/61 |
| 158 | 80 mm |
| 159 | 100 mm |
| 160 | 150 mm |
| 161 | 200 mm |
| 162 | 250 mm |
| 163 | 300 mm |
| 164 | 350mm diameter |
| 165 | 400mm diameter |
| 166 | 450mm diameter |
| 167 | Providing, fixing, laying & testing of double flanged cast iron (horizontal cast )pipe as per IS: 7181of One Meter length.3.1/39 |
| 168 | 100 mm |
| 169 | 150 mm |
| 170 | 200 mm |
| 171 | 250 mm |
| 172 | 300 mm |
| 173 | 350mm diameter |
| 174 | 400mm diameter |
| 175 | Labour for cutting following cast iron pipes of any type and class.19.1/239 |
| 176 | 100 mm |
| 177 | 150 mm |
| 178 | 200 mm |
| 179 | 250 mm |
| 180 | 300 mm |
| 181 | 350 mm |
| 182 | 400 mm |
| 183 | Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.18.2.8/228 |
| 184 | Providing and laying in position Plain cement concrete (PCC) of specified grade excluding the cost of centering and shuttering 18.14.3 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximumsize of stone aggregate18.14.3/229 |
| 185 | Providing,SupplyingandlayingBlueMDPE (medium density polyethylene) pipes conformingtoISO4427:1996manufactured from virgin resin PE 80 Food grade compounded RawMaterial having Blue Colour only with quality assurance certificatefromqualityagencies likeCIPET (India) andother recognisedagencies for usage inDrinkingWaterSystem.Thecost shall include testing of all materials, Inspectioncharges, transportationuptosite, transit insurance, loading, unloading, stacking etc. complete.20mm dia 7.11/110 |
| 186 | Providingand fixinggunmetal/ brass check (non-return) valves Class-I, female ends, tested to 21.09 kg/sq.cm. Screwed type6.7/90 |
| 187 | 15 mm |
| 188 | 20 mm |
| 189 | 25 mm |
| 190 | 32 mm |
| 191 | 50 mm |
| 192 | Providing & fixing water taps Stainless 6.17/92Steel, |
| 193 | 15 mm |
| 194 | 20 mm |
| 195 | Transportation By Mechanical means including loading, unloading and stacking.Sand, stone aggregate below 40 mm . Upto 3 km1.3/12 vol.iii Please Enable Macros to View BoQ information |