| 1 | Excavating trenches of required width for pipes, cables etc. in/c excavation for sockets and dressing of sides, where required ramming of bottom, depth up to 1500 mm ( Slope 1 in 200) in/c getting out the excavated soil and backfilling of soil as required after laying of pipe line, in layer not exceeding 200mm in depth in/c consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed with all required lead as per Chapter-2 of CPWD specification & direction of the Engineer-in-Charge. A). For UPVC pipes in new work.a). In all kinds of soil. i). For pipes not exceeding 90mm dia |
| 2 | ii). For pipes exceeding 90mm dia but not exceeding 300mm dia. |
| 3 | Providing fixing and laying rigid UPVC pipe conforming to IS:4985 jointing with coupler of same class conforming to IS: 10124 (Pt.II) with solvent cement conforming to IS: 14182 in/c testing of joint complete but ex/c the cost of specials like bend,tees, etc. which will be paid seperately as per CPWD specification & direction of the Engg.-in-charge. (A) Class-3 (Working Pressure 6.0kg/cm2). (i) 40mm OD |
| 4 | ii). 50mm OD |
| 5 | iii). 90mm OD |
| 6 | iv). 110mm OD |
| 7 | v). 140mm OD |
| 8 | Charges for repairing of leakage in UPVC / HDPE pipe line with PVC coupler & solvent cement etc. including necessary earth excavation, backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in charge. i). 90 mm dia |
| 9 | ii). 110mm dia |
| 10 | iii). 140mm dia |
| 11 | Charges for dismantling PVC / HDPE pipe after necessary excavation of earth including washing and stacking of pipes properly at site with all leads and lifts and backfilling of soil as required in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in charge. i. 90 mm dia. |
| 12 | ii). 110mm OD |
| 13 | iii). 140mm OD |
| 14 | Washing & removal of deposited iron sludge & any other foreign materials from inside the existing water distribution pipeline(PVC) using the UPVC coil pipe washing rod fitted with iron brush in/c excavation trenches upto required depth with cutting of C.I/D.I/G.I pipes at a lenght of every 55mtr. interval or post thereof ant jointing of pipes & specials as required refilling trenches with available excavated earth etc. complete as per direction of the Engg.-in-charge (Rate in/c making PVC couplers,cost of cement solvent PVC pipe for making PVC coupler will be issued by the department at free of cost) i) 90mm OD |
| 15 | ii) 110 mm dia |
| 16 | iii) 140 mm dia. |
| 17 | Washing & removal of deposited iron sludge & any other foreign materials from inside the existing water distribution pipeline (C.I. & D.I) using the UPVC coil pipe washing rod fitted with iron brush in/c excavation trenches upto required depth with cutting of C.I/D.I/G.I pipes at a lenght of every 55mtr. interval or post thereof ant jointing of pipes & specials as required refilling trenches with available excavated earth etc. complete as per direction of the Engg.-in-charge (Cost of C.I specials lead joints, rubber gusket joint will be issued by the department at free of cost). i. 150mm OD |
| 18 | Providing and laying of flexible PVC pipe (conforming to IS:7634) complete as per specification and direcction of the Engineer-in-charge (cost of earth work and fittings will be paid separately). (a). 15mm dia |
| 19 | Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in -charge. (i). 110 x 90 mm dia |
| 20 | Providing and fixing brass ferrule with C.I. cover conforming toIS : 2692 including boring and tapping the main as per CPWDspecification and direction of the Engineer - in - charge. i. 10 mm nominal bore. |
| 21 | Providing & fixing G.I Socket as per CPWD specification and direction of Engineer-in-charge. i. 15mm dia |
| 22 | ii. 40mm dia |
| 23 | Providing & fixing of G.I. union joints as per CPWD specification and direction of Engineer-in-charge. (i). 50mm dia |
| 24 | ii). 40mm dia |
| 25 | iii). 15 mm dia |
| 26 | Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge.B. by manual means. |
| 27 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. (i). 80mm dia (PN-1.6) |
| 28 | (ii). 100mm dia. (PN-1.6) |
| 29 | (iii). 125mm dia. (PN-1.6) |
| 30 | (iv). 150mm dia. (PN-1.6) |
| 31 | Providing and fixing DI specials as per CPWD specification and direction of the Engineer - in - charge. F) D.I flanged socketted tail piece. i) 80 mm dia |
| 32 | ii) 100 mm dia |
| 33 | iii). 125mm dia |
| 34 | iv). 150mm dia |
| 35 | G) D.I flange spigotted tail piece. i). 80mm dia |
| 36 | ii). 100mm dia |
| 37 | iii). 125mm dia |
| 38 | iv). 150mm dia. |
| 39 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i). 15mm dia |
| 40 | Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge. i). 15 mm dia PVC /plastic bib cock |
| 41 | Providing and fixing G.I. Nipple of medium class as per CPWD specification and direction of the Engineer - in - charge. i. 15mm dia 75mm long. |
| 42 | ii. 15mm dia 150mm long. |
| 43 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. (i). 40mm dia |
| 44 | (ii). 50 mm dia |
| 45 | (iii). 90 mm OD |
| 46 | (iv). 110 mm dia |
| 47 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge. A. External work. (i). 15mm dia (For Stand Post) |
| 48 | Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per chapter 20 of CPWD specification and direction of the Engineer - in - charge. i.) 90 mm dia |
| 49 | (ii). 110mm dia |
| 50 | Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i). 90 x 90mm dia |
| 51 | ii). 110 x 110 mm dia |
| 52 | Providing, fixing and laying flanged fabricated UPVC tailpiece with MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part 6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction ofthe Engineer - in - charge. i). 90mm dia |
| 53 | ii). 110 mm dia Please Enable Macros to View BoQ information |