| 1 | Complete servicing of AC machines (Indoor & Outdoor Unit) as per direction of the Engineer-in-charge. |
| 2 | 1.0/1.5/2.0/3.0 TR split type AC. |
| 3 | 3.0 TR vertical type AC. |
| 4 | Leak testing of condenser & evaporator unit for performance and pressure testing etc and repair with brazing as per direction of the Engineer-in-charge. |
| 5 | 1.0/1.5/2.0/3.0 TR High wall split and vertical type AC. |
| 6 | 3.0 TR vertical type AC. |
| 7 | Charging of fresh refrigerant gas (R-22) for 1.0/1.2/1.5/2.0/3.0 TR capacity High wall split/window/cassette / vertical AC system as per direction of the Engineer-in-charge. |
| 8 | Charging of fresh refrigerant gas (R-32) for 1.0/1.5/2.0/3.0 TR capacity High wall split/window/cassette / vertical AC system as per direction of the Engineer-in-charge. |
| 9 | Providing, fitting and fixing of hermetically sealed compressor for replacement of defective one of fixed speed AC system as per direction of the Engineer-in-charge. (With one year warranty) |
| 10 | 1.5 TR capacity High wall split type AC. |
| 11 | 2.0 TR capacity High wall split and cassette type AC. |
| 12 | 3.0 TR capacity High wall split/vertical and cassette type AC. |
| 13 | Providing, fitting and fixing of hermetically sealed compressor for inverter technology AC machine as per direction of the Engineer-in-charge. (With one year warranty) |
| 14 | 1.0 TR capacity High wall split and cassette type AC |
| 15 | 1.5 TR capacity High wall split and cassette type AC |
| 16 | 2.0 TR capacity High wall split and cassette type AC. |
| 17 | 3.0 TR capacity High wall split/vertical and cassette type AC. |
| 18 | Providing, fitting and fixing of hermetically sealed copper condenser unit for replacing old one as per direction of the Engineer-in-charge. |
| 19 | 1.5 TR capacity High wall split and cassette type AC |
| 20 | 2.0 TR capacity High wall split and cassette type AC. |
| 21 | 3.0 TR capacity High wall split /vertical and vertical type AC |
| 22 | Fitting, fixing of blower motor of Ac systems after rewinding I/C necessary replacement of bush, shaft etc with complete varnishing as per direction of the Engineer-in-charge. |
| 23 | Providing and fitting fixing of scroll motor (A.C type) of indoor unit split type AC system as per direction of the Engineer-in-charge. |
| 24 | Providing and fitting fixing of scroll motor (D.C type) of indoor unit for inverter technology split type AC system as per direction of the Engineer-in-charge. |
| 25 | Providing, fitting and fixing of swing motor of indoor unit split type AC system as per direction of the Engineer-in-charge. |
| 26 | Providing, fitting and fixing of indoor PCB circuit for inverter technology split/cassete/Vertical type AC system as per direction of the Engineer-in-charge. |
| 27 | 1.0/1.5/2.0/3.0 TR capacity High wall split type AC |
| 28 | Providing, fitting and fixing of outdoor PCB circuit for inverter technology split/cassete type AC system as per direction of the Engineer-in-charge. |
| 29 | 1.0/1.5/2.0/3.0 TR capacity High wall split/vertical type AC |
| 30 | Providing and fitting fixing PCB circuit for fixed speed split/vertical type AC as per direction of the Engineer-in-charge. |
| 31 | 1.0/1.5/2.0/3.0 TR capacity High wall split/vertical type AC |
| 32 | Supply and installation of additional length of copper pipe of approximate size of 1/4\\" (6.35mm), 3/4\\"(19.05mm), 3/8\\"(9.53mm),5/8\\"(15.88) and 1/2\\"(12.7 mm) or all nearest dia as per manufacturer design for both suction and liquid line with insulation and necessary wiring (with three pin electrical plug) to connect the indoor and outdoor units for 1.0/1.5/2.0/3.0TR split type high wall AC machines as per direction of the Engineer-in-charge. |
| 33 | Fabrication of M.S platform for placement of condensing unit by using M.S angel of (50x50x5)mm/(65x65x5)mm size base plate, nuts & bolts/universal bracket (GSS) for ODU of split type AC system including all accessories for on-site installation i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-charge. |
| 34 | Dismantling and re-installation of 1.0/1.5/2.0/3.0 TR window, split, vertical and cassette type AC system as per direction of the Engineer-in-charge. |
| 35 | Providing hard/ coil PVC pipe of good quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge |
| 36 | Providing, fitting and fixing of accessories during maintenance work of window/split type AC system as per direction of the Engineer-in-charge. |
| 37 | 2.0/2.5/4.0/5.0 mfd (fan capacitor) |
| 38 | 25mfd capacitor |
| 39 | 36 mfd capacitor |
| 40 | 45mfd capacitor |
| 41 | (50-60) mfd capacitor |
| 42 | (80-120) mfd capacitor |
| 43 | Terminal Clip |
| 44 | PVC tape (Black tap) |
| 45 | Thermostat |
| 46 | Selector switch |
| 47 | Relay |
| 48 | Coil sensor |
| 49 | Room sensor |
| 50 | Display with sensor |
| 51 | Nitral tape (Arrow tape) |
| 52 | Connector |
| 53 | Remote with Battery |
| 54 | Air Filter |
| 55 | Single core copper wire 1.5/2.5 Sq.mm made of (Havels/Anchor) |
| 56 | General Checking of split type AC & cleaning of Filters of Indoor units and Coils of Outdoor units of a AC system as per direction of the Engineer-in-charge. |
| 57 | Supply and installation of additional length of electrical copper wire 4 mm size with casing size 01 (One) inch including other materials to connect outdoor unit with electrical panel as per direction of the Engineer-in-charge. |
| 58 | Providing, fitting and fixing of fan blade of outdoor unit of window, split, cassette and vertical type AC system as per direction of the Engineer-in-charge. |
| 59 | Providing, charging of compressor oil with capillary complete per direction of the Engineer-in-charge. Please Enable Macros to View BoQ information |