| 1 | Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required. |
| 2 | 4 x 185 sq.mm |
| 3 | 4 x 120 sq.mm |
| 4 | 4 x 70 sq.mm |
| 5 | 4 x 50 sq.mm |
| 6 | 4 x 35 sq.mm |
| 7 | 4 x 25 sq.mm |
| 8 | 4 x 16 sq.mm |
| 9 | 4 × 10 sq.mm |
| 10 | 3 × 10 sq.mm |
| 11 | 3 × 6 sq.mm |
| 12 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 13 | Up to 35 Sq mm |
| 14 | Above 35 sq. mm and upto 95 sq. mm |
| 15 | Above 95 sq. mm and upto 185 sq. mm |
| 16 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 17 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 18 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 19 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPEaluminium conductor cable of 1.1 KV grade as required. |
| 20 | 3 X 10 sq. mm (22mm) |
| 21 | 4 X 10 sq. mm (25mm) |
| 22 | 4 X 16 sq. mm (28mm) |
| 23 | 4 X 25 sq. mm (28mm) |
| 24 | 4 X 35 sq. mm (32mm) |
| 25 | 4 X 50 sq. mm (32mm) |
| 26 | 4 X 70 sq. mm (45mm) |
| 27 | 4 X 120 sq. mm (45mm) |
| 28 | 4 X 185 sq. mm (57mm) |
| 29 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 30 | Design, Fabrication, Supplying, Installation, Testing and commissioning of floor Mounted Dust and vermin proof Cubicle type MV Panel board suitable for 3 Phase, 415v, 50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14/16 SWG CRCA Sheet Steel with doors and painted with powder coating in approved shade, ELR with CBCT, Complete with aluminium busbars of adequate capacity for Phases & neutral, Suitable M.S Angle Base Frame of 75 X 75 mm, interconnections control wiring, including incoming and outgoing cables connections, Door Earthing 2.5 mm Flexible Copper, suitable spread terminals for MCCBs, danger plate etc as required at site of work and as directed by the Engineer in charge. of following sizes and switchgear: |
| 31 | Size: 150 x 135 x 35 cm with 2 mm CRCA Sheet with doorsBus Bar Size: 30 x 6 mm Aluminium- 4 no.s- 140mm length each.Earth Bar: 25 x 6 mm Copper- 1 no. 140mm length each.Incoming: 4 pole MCCB, 150A, 36KA- 1 No with extended rotary handleOutgoing: 100A, 4 pole MCCB, 30KA- 1 No with extended rotary handle63A, 4 pole MCCB, 25/30KA- 4 Nos with extended rotary handle63A, 4 Pole MCB, 10KA- 02 Nos32A, 2 Pole MCB, 10KA -02NosMetering PannelingDigital Voltmeter - 01 NosDigital Ammeter - 01 NosRYB phase indication lamps -1 set |
| 32 | Design, Fabrication, Supplying, Installation, Testing and commissioning of Concrete base Mounted Dust and vermin proof Cubicle type double door Feeder pillar box suitable for 3 Phase, 415v, 50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel with doors and painted with powder coating in approved shade, ELR with CBCT, Complete with aluminium busbars of adequate capacity for Phases & neutral, Suitable M.S Angle Base Frame of 75 X 75 mm, interconnections control wiring, including incoming and outgoing cables connections, Door Earthing 2.5 mm Flexible Copper, suitable spread terminals for MCCBs, danger plate etc as required at site of work and as directed by the Engineer in charge. of following sizes and switchgear: |
| 33 | Size: 120 x 120 x 35 cm with 2 mm CRCA Sheet with doors Bus Bar Size: 30 x 6 mm Aluminium- 4 no.s- 110mm length each.Earth Bar: 25 x 6 mm Copper- 1 no. 110mm length.Incoming:100A, 4 pole MCCB, 36KA- 2 No with extended rotary handleOutgoing: 63A, 4 pole MCCB, 25/30KA- 4 Nos with extended rotary handle32A, 4 Pole MCB, 10KA- 1 Nos Metering PannelingDigital Voltmeter - 01 NosDigital Ammeter - 01 NosRYB phase indication lamps -1 set6A SP MCB for control Ckts -03 Nos |
| 34 | Design, Fabrication, Supplying, Installation, Testing and commissioning of wall mounted bus bar box suitable for 3 Phase, 415v, 50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel with doors and painted with powder coating in approved shade Complete with aluminium busbars of adequate capacity for Phases & neutral, interconnections control strips including incoming and outgoing cables connections, Door Earthing 2.5 mm Flexible Copper, suitable spread terminals for MCCBs, danger plate etc as required at site of work and as directed by the Engineer in charge. of following sizes and switchgear: |
| 35 | Size: 60 x 60 x 35 cm with 2 mm CRCA Sheet with doors with suitable bus bar strips for 3 phases and neutral, R-Y-B indication lamp along with input- 63A MCCB 3 no.s as of site requirement. |
| 36 | Supply, testing and commissioning of 6 meter high octagonal pole made of hot dip galvanised G.I. sheet 70 mm top diameter, 130 mm bottom diameter, thickness 3 mm, base plate dimensions of 200 x 200 x 14 mm, suitable for wind speed as per IS 875 part III, fixed head frame including 2 m channel arm bracket luminary carriage suitable to install 2 nos luminiaries including connecotrs and blanket strip for support, 3C 1.5 sq. mm copper wire for connection, 6A SP MCB for control, 4 nos EN-8 grade M20x600 mm foundation bolt fixed in existing RCC foundation along with nuts, washers, anchor plate etc., complete as required. |
| 37 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 38 | Above 4.5 Meter and upto 6.5 Meter |
| 39 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 40 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 41 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 42 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 43 | 90 W (DSR EM 2025 -Item no. 8.12.14) |
| 44 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 ̊C to 50 ̊C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10%as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 45 | 100 W |
| 46 | Credit Items |
| 47 | Dismantled scrap of MS conduit/DB's/GI wir/clamps etc. Please Enable Macros to View BoQ information |