| 1 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete two coat of enamal Paint . |
| 2 | Depth up to 1.5mExcavation in foundation / trenches / pits drains etc. in all soils upto a required depth No.t exceeding 1.5 mtrs. Including shoring and dewatering if necessary and refilling around foundation plinth and drain line with selected excavation earth in layers Not exceeding 250mm consolidating and disposing surplus earth out of hospital premises complete all as directed by the Engineer-in-Charge. |
| 3 | 225mm thick Providing & laying rubble stone soling using spotless stones below floors roads/pavements etc. mechanically / manually consolidated thickness as specified below with stones vertically handset interstices packed with smaller stone chips, binding with murrum & sprinkling water for proper consolidating and finishing to required levels in quantities as and when required etc. complete all as directed by the Engineer-in-Charge. |
| 4 | PCC M10Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommendedproportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; butexcluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cementcontent, the contractor shall have discretion to either re-design the mixor bear the cost of extra cement. |
| 5 | ACP :Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel materialconsisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF /Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather siliconesealant, backer rods etc. |
| 6 | CHAIN LICK FENCING Providing and fixing G.I. chain link fabric fencing of required width inmesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as requiredcomplete as per the direction of Engineer-in-charge. : Made of G.I. wire of dia 3 mm |
| 7 | Vinyl Stickering for Signage for signage:Supply and installation of premium self-adhesive polymeric vinyl graphics, minimum 70 micron thick with permanent solvent acrylic pressure-sensitive adhesive, digitally printed using eco-solvent/UV inks at minimum 720 dpi resolution, including UV-protective cold lamination, complete with surface preparation, alignment, trimming, and application on approved substrates as per drawings and manufacturer recommendationsetc. complete, all as per direction of Engineer-in-charge. |
| 8 | Alluminium framing :Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge. |
| 9 | Light shade pigment using white cement chequared tiles Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 10 | Extranal apint Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 11 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 12 | Epoxy flooring a multi-coat system, typically 2–5mm thick, featuring a prime coat, an optional screed/mortar layer for leveling, and a high-solid epoxy topcoat for chemical and abrasion resistance. Performance standards include compressive strength >5000 psi, flexural strength >2000 psi, and strict surface preparation (moisture 4%). Please Enable Macros to View BoQ information |